Shear strength and failure behavior of precast concrete sandwich panels under elevated temperatures: Experimental and numerical investigation
Source abstract
Abstract
Global warming is causing a continuous rise in global temperatures, which negatively impacts the strength, and durability of concrete structures. Precast concrete sandwich (PCS) structures have become increasingly popular due to their energy efficiency and lightweight properties. However, the mechanical properties of core insulation materials can degrade at elevated temperatures above 50°C due to softening, compromising the overall strength and durability of the structure. This study investigates the shear strength capacity of concrete sandwich panels using double shear (push-out) tests. A total of 14 double-shear specimens were fabricated and tested with varying shear connector spacing. The tests were conducted under ambient conditions and after exposure to elevated temperatures of 50°C and 75°C using a thermal furnace. The results reveal a significant reduction in shear capacity at higher temperatures, primarily due to reduced bond strength between the concrete and insulation material. Additionally, the study examines failure modes of specimens with and without connectors under different temperature conditions. Finite element modeling was utilized to simulate the performance of PCS specimens under both ambient and elevated temperatures. The study recommends the parameters for cohesive surface interaction properties between the insulation material and concrete to enhance the accuracy of numerical simulations.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Civil and Environmental Engineering, IIT Patna, Patna, India
Funding
Ministry of Education, Government of India
References (37)
Show source-provided references
1. 10.1016/j.conbuildmat.2019.11714510.1016/j.conbuildmat.2019.117145 ↗
2. 10.3390/su903047210.3390/su9030472 ↗
3. Khan MS, Nacer N, Khan S. Thermal analysis of RC building using ETABS-Part 1. Int. J. Civ. Eng. Technol 2023; 14(5): 83–94.
4. 10.15554/pcij56.2-0610.15554/pcij56.2-06 ↗
5. 10.1016/j.compstruct.2014.10.03210.1016/j.compstruct.2014.10.032 ↗
6. 10.15554/pcij.03012011.42.5410.15554/pcij.03012011.42.54 ↗
7. 10.1016/j.compositesb.2015.04.05610.1016/j.compositesb.2015.04.056 ↗
8. 10.1016/j.compositesb.2018.08.08110.1016/j.compositesb.2018.08.081 ↗
9. 10.1061/(ASCE)ST.1943-541X.000043010.1061/(ASCE)ST.1943-541X.0000430 ↗
10. 10.1617/s11527-015-0760-x10.1617/s11527-015-0760-x ↗
11. 10.1016/j.compositesb.2019.02.03010.1016/j.compositesb.2019.02.030 ↗
12. Wade GT, Porter ML, Jacobs DR. Glass-fiber composite connectors for insulated concrete sandwich walls. Iowa State University College of Engineering, 1988.
13. 10.15554/pcij.07011994.90.10110.15554/pcij.07011994.90.101 ↗
14. 10.1016/j.compstruct.2018.09.01710.1016/j.compstruct.2018.09.017 ↗
15. 10.4028/www.scientific.net/AMM.204-208.80310.4028/www.scientific.net/AMM.204-208.803 ↗
16. El-Baraga MF, Attia WA, Ibrahim H. Evaluation of shear behavior for various designed configurations of wythe ties in precast concrete sandwich panels. Des Eng 2021: 11220–11247.
17. 10.4028/www.scientific.net/AMR.663.15410.4028/www.scientific.net/AMR.663.154 ↗
18. 10.1061/(ASCE)CC.1943-5614.000055410.1061/(ASCE)CC.1943-5614.0000554 ↗
19. 10.15554/pcij.07012007.70.8310.15554/pcij.07012007.70.83 ↗
20. Bureau of Indian Standards. IS 456:2000 - code of practice for plain and reinforced concrete. New Delhi: Bureau of Indian Standards, 2000.
21. ASTM Committee D-20 on Plastics. Standard test method for compressive properties of rigid cellular plastics. ASTM International, 2004.
22. Bureau of Indian Standards. IS 1786:2008 - high strength deformed steel bars and wires for concrete reinforcement - specification. New Delhi: Bureau of Indian Standards, 2008.
23. 10.1177/1099636221106315210.1177/10996362211063152 ↗
24. 10.1016/j.engstruct.2013.09.00410.1016/j.engstruct.2013.09.004 ↗
25. Simulia DS. Abaqus 6.11 theory manual. Providence. RI. USA: Dassault Systemes Simulia Corp, 2011.
26. 10.1061/JSDEAG.000295710.1061/JSDEAG.0002957 ↗
27. Gopalaratnam VS, Shah SP. Softening response of plain concrete in direct tension. J. Am. Concrete Ins 1985; 82(3): 310–323.
28. Price WH. Factors influencing concrete strength. J. Am. Concrete Ins 1951; 47(2): 417–432.
29. 10.1002/eqe.293210.1002/eqe.2932 ↗
30. 10.1061/(ASCE)0733-9399(1998)124:8(892)10.1061/(ASCE)0733-9399(1998)124:8(892) ↗
31. 10.1016/j.engstruct.2012.12.01710.1016/j.engstruct.2012.12.017 ↗
32. EPS White Book. EUMEPS background information on standardisation of EPS. European Manufacturers of Expanded Polystyrene, 2011.
33. Eurocode 2. Design of concrete structures- Part 1-2: General rules- Structural fire design. European committee for standardization, 2004.
34. 10.1680/gein.2009.16.5.37410.1680/gein.2009.16.5.374 ↗
35. 10.1061/(ASCE)CC.1943-5614.000066210.1061/(ASCE)CC.1943-5614.0000662 ↗
36. 10.1016/j.polymertesting.2018.12.00110.1016/j.polymertesting.2018.12.001 ↗
37. Bureau of Indian Standards. IS 800:2007 - general construction in steel – code of practice. New Delhi: Bureau of Indian Standards, 2007.