Collision Mechanism and Deposition Characteristics of Particles on the Catenary Insulator Surface
Source abstract
Abstract
To solve the problem of contamination flashover of a catenary insulator in an electrified railway, the collision mechanism and deposition characteristics of contamination particles on the insulator surface should be studied to ensure the safe operation of traction power supply systems. This research used horizontal and oblique cantilever insulators as objects, and established the collision model between particles and insulator surface under different arrangements. The deposition conditions of particles on the insulator surface were obtained, and the simulation model of insulator contamination accumulation was established by using the Euler two-phase flow. The difference of contamination deposition characteristics between horizontal and oblique cantilever insulators was analyzed with the volume fraction of contamination particles as the characterization parameter. By comparing the cantilever insulator with the positive feeder insulator, this study analyzed the influence of shed structure on the contamination deposition characteristics. Results show that the installation method of an insulator has an impact on the contamination deposition on the insulator surface. When particle size and wind velocity are fixed, the degree of contamination accumulation on the surface of the oblique cantilever insulator is constantly higher than that of the horizontal cantilever insulator. The insulator shed structure also has a certain effect on the contamination deposition on the insulator surface. For the cantilever insulator, the degree of contamination accumulation of the windward side is higher than that of the leeward side. However, for the positive feeder insulator, the degree of contamination accumulation of the windward side is consistently less than that of the leeward side. Measures to deal with contamination flashover of catenary insulator are proposed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Aerosol Filtration and Electrostatic Precipitation · Aerodynamics and Fluid Dynamics Research · Vehicle emissions and performance
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Automation & Electrical Engineering, Lanzhou Jiaotong University, Anning District, Lanzhou 730070, China
Key Laboratory of Opto-Technology and Intelligent Control Ministry of Education, Lanzhou Jiaotong University, Anning District, Lanzhou 730070, China
Rail Transit Electrical Automation Engineering Laboratory of Gansu Province, Lanzhou Jiaotong University, Anning District, Lanzhou 730070, China
Funding
Natural Science Foundation of China
References (27)
Show source-provided references
1. China Railway Corporation (2014). The Technology of High-speed Railway Catenary, China Railway Press.
2. Zhao, S., Zhang, C., Zhang, Y., and Wang, S. (2019). Influence of partial arc on electric field distribution of insulator strings for electrified railway catenary. Energies, 12.10.3390/en12173295 ↗
3. Electric field calculation for an axially-symmetric insulator with surface contamination10.1109/94.300266 ↗
4. Modeling flashover of AC outdoor insulators under contaminated conditions with dry band formation and arcing10.1109/TDEI.2012.6215110 ↗
5. Investigations on AC pollution flashover performance of insulator string under different non-uniform pollution conditions10.1049/iet-gtd.2015.0691 ↗
6. Xu, J., Yin, F., Li, L., Wen, Q., Wang, H., Liu, S., Jia, Z., and Farzaneh, M. (2019). Wet snow flashover characteristics of 500-kV AC insulator strings with different arrangements. Appl. Sci., 9.10.3390/app9050930 ↗
7. Jiang, X., Wang, Q., Zhang, Z., Hu, J., Hu, Q., and Zhu, C. (2017). Ion migration in the process of water freezing under alternating electric field and its impact on insulator flashover. Energies, 10.10.3390/en10010061 ↗
8. Numerical analysis of contamination characteristics of new type insulator for catenary cantilever
9. Pollution accumulation on rail insulator in high-speed aerosol10.1109/TDEI.2013.6518942 ↗
10. Pollution accumulation characteristics of insulators under natural rainfall10.1049/iet-gtd.2016.1077 ↗
11. Collision and adsorption of pollution particles on the surface of electrical insulator
12. Particle contamination of high voltage DC insulators below corona threshold10.1109/TEI.1979.298185 ↗
13. Hernandez-Corona, R., Ramirez-Vazquez, I., and Montoya-Tena, G. (2004, January 19–22). Evaluation of 23 kV insulator profiles with different pollution levels. Proceedings of the 2004 IEEE International Symposium on Electrical Insulation, Indianapolis, IN, USA.
14. Natural contamination characteristics of suspension insulator in Hunan Province
15. Model optimization of pollution deposition criterion of insulators based on energy10.1109/TDEI.2017.006666 ↗
16. Zhang, M., Wang, R., Li, L., and Jiang, Y. (2018). Size distribution of contamination particulate on porcelain insulators. Coatings, 8.10.3390/coatings8100339 ↗
17. Influence of pollution constituents on DC flashover of high voltage insulators10.1109/TDEI.2013.6508740 ↗
18. Optimization of the contamination particle deposition model based on humidity and surface energy10.1016/j.applthermaleng.2019.113734 ↗
19. Ren, J. (2005). Particle Dispersion Science and Technology, Chemical Industry Press. (In Chinese).
20. Zhang, W., Qi, H., You, C., Bao, Y., and Xu, X. (2002, January 1). Particle collision simulation and numerical study. Proceedings of the Chinese Society of Engineering Thermophysics 2002 Conference on Multiphase Flow Technology, Dalian, China.
21. Research on elastoplastic normal impact of steel spheres against a rigid plane
22. Study on natural contamination performance of typical types of insulators10.1109/TDEI.2014.004343 ↗
23. Analysis and suggestion of several key influencing factors in computational wind engineering
24. Particle size distribution characteristics of naturally polluted insulators in service of HVDC transmission line
25. Numerical simulation of response law of wind-blown sand flow around the railway embankment
26. Pollution distribution characteristic of high-speed train roof insulator and its optimization strategy
27. Tang, Q. (2017). Contamination Characteristics and Electric Field Distribution of High Voltage Insulators. [Master’s Thesis, Suzhou University].