journal article·2021-11-22Open access

Effect of the Acid-Etching on Grit-Blasted Dental Implants to Improve Osseointegration: Histomorphometric Analysis of the Bone-Implant Contact in the Rabbit Tibia Model

Blanca Ríos-Carrasco, Bernardo Ferreira Lemos, Mariano Herrero-Climent, F. Javier Gil Mur, Jose Vicente Ríos-Santos

Coatings· Volume 11· Issue 11

Abstract

Previous studies have shown that the most reliable way to evaluate the success of an implant is by bone-to-implant contact (BIC). Recent techniques allow modifications to the implant surface that improve mechanical and biological characteristics, and also upgrade osseointegration. Objective: The aim was to evaluate the osseointegration in rabbit tibia of two different titanium dental implant surfaces: shot-blasted with Al2O3 (SB) and the same treatment with an acid-etching by immersion for 15 s in HCl/H2SO4 (SB + AE). Material and methods: Roughness parameters (Ra, Rt, and Rz) were determined by white light interferometer microscopy. Surface wettability was evaluated with a contact angle video-based system using water, di-iodomethane, and formamide. Surface free energy was determined by means of Owens and Wendt equations. Scanning electron microscopy equipped with X-ray microanalysis was used to study the morphology and determine the chemical composition of the surfaces. Twenty-four grade 4 titanium dental implants (Essential Klockner®) were implanted in the rabbit’s tibia, 12 for each surface treatment, using six rabbits. Six weeks later the rabbits were sacrificed and the implants were sent for histologic analysis. Resonance frequency analysis (RFA) was recorded both at the time of surgery and the end of the research with each device (Osstell Mentor and Osstell ISQ). Results: The roughness measurements between the two treatments did not show statistically significant differences. However, the effect of the acid etching made the surface slightly more hydrophilic (decreasing contact angle from 74.7 for SB to 64.3 for SB + AE) and it presented a higher surface energy. The bone-to-implant contact ratio (BIC %) showed a similar tendency, with 55.18 ± 15.67 and 59.9 ± 13.15 for SB and SB + AE implants, respectively. After 6 weeks of healing, the SB + AE showed an implant stability quotient (ISQ) value of 76 ± 4.47 and the shot-blasted one an ISQ value of 75.83 ± 8.44 (no statistically significant difference). Implants with different surface properties had distinctive forms of behavior regarding osseointegration. Furthermore, the Osstell system was an invasive and reliable method to measure implant stability. Conclusion: Both surfaces of implants studied showed high osseointegration. The SB and SB + AE implants used in our study had similar behavior both in terms of BIC values and RFA. The RFA systems in Osstell Mentor and Osstell ISQ confirmed nearly perfect reproducibility and repeatability.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Periodontology, Dental School, University of Seville, 41009 Seville, Spain

Department of Dentistry and Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, 4249-004 Porto, Portugal

Department of Periodontology, Porto Dental Institute, 4150-518 Porto, Portugal

Bioengineering Institute of Technology, Facultad de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallés, Spain

Faculty of Dentistry, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallés, Spain

References (37)

Show source-provided references
1. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
2. Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in Man10.3109/17453678108991776 ↗
3. Davies, J.E. (1999). Bone Formation and Healindg: Histodynamics of endosseous Wound Healing. Bone Engineering, Springer.
4. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
5. El Hassanin, A., Quaremba, G., Sammartino, P., Adamo, D., Miniello, A., and Marenzi, G. (2021). Effect of Implant Surface Roughness and Macro- and Micro-Structural Composition on Wear and Metal Particles Released. Materials, 14.10.3390/ma14226800 ↗
6. Marenzi, G., Impero, F., Scherillo, F., Sammartino, J.C., Squillace, A., and Spagnuolo, G. (2019). Effect of Different Surface Treatments on Titanium Dental Implant Micro-Morphology. Materials, 12.10.3390/ma12050733 ↗
7. Surface Roughness of Dental Implant and Osseointegration10.1007/s12663-020-01437-5 ↗
8. Improved osseointegration of dental titanium implants by TiO2 nanotube arrays with recombinant human bone morphogenetic protein-2: A pilot in vivo study
9. In vivo comparison between the effects of chemically modified hydrophilic and anodically oxidized titanium surfaces on initial bone healing10.5051/jpis.2015.45.3.94 ↗
10. Variation of roughness and adhesion strength of deposited apatite layers on titanium dental implants10.1016/j.msec.2010.09.018 ↗
11. Implants in bone: Part I. A current overview about tissue response, surface modifications and future perspectives
12. Advances in surfaces and osseointegration in implantology. Biomimetic surfaces10.4317/medoral.20353 ↗
13. A histomorphometric study of dental implants with different surface characteristics10.4047/jap.2010.2.4.142 ↗
14. Oral implant surfaces: Part 1- review focusing on topographic and chemical properties of different surfaces and in vivo responses to them
15. Bone tissue response to plasma-nitrided titanium implant surfaces10.1590/1678-775720140376 ↗
16. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis10.1034/j.1600-0501.1996.070308.x ↗
17. Determination of the Optimum Torque to Tighten the Smartpegs of Magnetic Resonance Frequency Analyses Devices: An Ex Vivo Study10.1563/aaid-joi-D-14-00266 ↗
18. Comparative Analysis of 2 Resonance Frequency Measurement Devices: Osstell Mentor and Osstell ISQ10.1097/ID.0000000000000072 ↗
19. Two different implant designs and impact of related drilling protocols on primary stability in different bone densities: An in vitro comparison study10.11607/jomi.3903 ↗
20. Relation between initial implant stability quotient and bone-implant contact percentage: An in vitro model study10.1016/j.oooo.2012.01.037 ↗
21. Analysis of different approaches for evaluation of surface energy of microbial cells by contact angle goniometry10.1016/S0001-8686(02)00004-0 ↗
22. The influence of blasting and sterilization on static and time-related wettability and surface-energy properties of titanium surfaces10.1016/j.surfcoat.2007.12.021 ↗
23. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs10.1002/jbm.820250708 ↗
24. Contact angles, work of adhesion, and interfacial tensions at a dissolving Hydrocarbon surface10.1016/0021-9797(87)90280-3 ↗
25. Tissue Reactions to Various Percutaneous Materials with Different Surface Properties and Structures10.1111/j.1525-1594.1997.tb00514.x ↗
26. Aluminum induced mitogenesis in MC3T3-E1 osteoblats: Potential mechanism underlying neoosteogenesis10.1210/endo-128-6-3144 ↗
27. Aluminum stimulates the proliferation and differentiation of osteoblasts in vitro by a mechanism that is the different from fluorine
28. Integration of screw implants in the rabbit: A 1-year follow-up of removal torque of titanium implants
29. Assessment of osstell isq’s reliability for implant stability measurement: A cross-sectional clinical study
30. Assessment of implant stability as a prognostic determinant
31. In vivo evaluation of micro-rough and bioactive titanium dental implants using histometry and pull-out tests10.1016/j.jmbbm.2011.05.005 ↗
32. Romero-Ruiz, M.M., Gil-Mur, F.J., Ríos-Santos, J.V., Lázaro-Calvo, P., Ríos-Carrasco, B., and Herrero- Climent, M. (2019). Influence of a Novel Surface of Bioactive Implants on Osseointegration: A Comparative and Histomorfometric Correlation and Implant Stability Study in Minipigs. Int. J. Mol. Sci., 20.10.3390/ijms20092307 ↗
33. Repeatability of the resonance frequency analysis values in implants with a new technology
34. Comparative evaluation of the stability of two different dental implant designs and surgical protocols—A pilot study10.1186/s40729-017-0078-2 ↗
35. Effects of a calcium phosphate coating on the osseointegration of endosseous implants in a rabbit model10.1111/j.1600-0501.2010.02056.x ↗
36. A comparative study on the accuracy of the devices for measuring the implant stability10.4047/jap.2009.1.3.124 ↗
37. Lo Giudice, R., and Tribst, J.P.M. (2020). Dental Materials Coatings:Efecto n the clinical behavior. Coatings, 10.10.3390/coatings10121229 ↗