Improved Biocompatibility of TiO2 Nanotubes via Co-Precipitation Loading with Hydroxyapatite and Gentamicin
Source abstract
Abstract
The antibacterial properties of titanium make it useful for clinical applications. Hydroxyapatite (HA) is widely utilized as a coating on orthopedic implants to improve osteointegration. Titanium oxide nanotubes (TNT) are recognized as a promising solution for local antibiotic therapy in bone implants. It is demonstrated that the utilization of HA-coated titanium can improve the biocompatibility of bone implants. This research aims to examine the antibacterial properties and biocompatibility of the TiO2 nanotubes by loading HA and gentamicin. In vitro testing, the characterization of drug release, cell adhesion and proliferation, bacteria culture, and antibacterial tests were conducted. During the in vivo experiments, Staphylococcus aureus was implanted into the femur of rats. The animals were sacrificed at four weeks followed by microbiological and clinical assessments on the bone, which were conducted by removing the implants followed by agar plating. The in vitro cell incubation demonstrated that the TiO2 nanotubes loaded with hydroxyapatite and gentamicin had better cellular compatibility compared to Cp–Ti. In addition, in vitro elution testing showed that gentamicin was released from the hydroxyapatite/TiO2 nanotubes for as long as 22 days. The release time was much longer than the TNT loaded with gentamicin at only 6 h. All animals in the gentamicin/HA/TNT group were free of infection compared to those in the Cp–Ti, TNT, and HA/gentamicin/TNT groups. There was a considerable reduction in the rates of infection among the rats with gentamicin-HA-TNT coatings compared to standard titanium. These results indicated that the co-precipitation of gentamicin and HA loading using the TNT method provided a novel prophylactic method against prosthetic infections and other biomedical applications.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Plastic Surgery, First Hospital of China Medical University, Shenyang 110002, China
Department of Neurosurgery, The First Hospital of China Medical University, Shenyang 110002, China
Department of Sports Medicine and Joint Surgery, First Affiliated Hospital of China Medical University, Shenyang 110002, China
Funding
Natural Science Foundation of Liaoning Province · National Natural Science Foundation of China · China Postdoctoral Science Foundation Project
References (22)
Show source-provided references
1. Anodied Ti and Ti6Al4V possessing nanometer surface features enhances osteoblast adhesion
2. Development of resistant strains of Staphylococcus epidermidis on gentamicin-loaded bone cement in vivo10.1302/0301-620X.84B5.0840758 ↗
3. Complications of external skeletal fxation
4. Drug/device combinations for local drug therapies and infection prophylaxis10.1016/j.biomaterials.2005.11.031 ↗
5. Prophylaxis and treatment of implant-related infections by local application of antibiotics10.1016/j.injury.2006.04.015 ↗
6. Beta-titanium alloy covered by ferroelectric coating-physicochemical properties and human osteoblast-like cell response10.3390/coatings11020210 ↗
7. Enhanced osteoblast adhesion to drug-coated anodized nanotubular titanium surfaces
8. Self-ordered nanopore and nanotube platforms for drug delivery applications10.1517/17425240903300857 ↗
9. Decreased Staphylococcus epidermis adhesion and increased osteoblast functionality on antibiotic-loaded titania nanotubes10.1016/j.biomaterials.2007.07.037 ↗
10. Controlled drug release from porous materials by plasma polymer deposition10.1039/b919840g ↗
11. Improved antibacterial activity and biocompatibility on Gentamicin-loaded TiO2 nanotubes: In vivo and in vitro studies10.2147/IJN.S53221 ↗
12. Horkavcová, D., Doubet, Q., and Jablonská, E. (2021). Development of adhesive, bioactive and antibacterial titania Sol-Gel coating on Titanium substrate by dip-coating technique. Coatings, 11.10.3390/coatings11020243 ↗
13. Biocompatible polymer coating of titania nanotube arrays for improved drug elution and osteoblast adhesion10.1016/j.actbio.2011.09.004 ↗
14. In vivo evaluation of anodic TiO2 nanotubes: An experimental study in the pig
15. Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old. A concise follow-up of a previous report10.2106/00004623-200305000-00017 ↗
16. Hydroxyapatite-coated femoral component: 15 –year minimum follow-up10.1097/01.blo.0000246534.44629.b2 ↗
17. Hydroxyapatite growth on anodic TiO2 nanotubes10.1002/jbm.a.30677 ↗
18. Mechanical behavior of a titanium alloy scaffold mimicking trabecular structure10.1186/s13018-019-1489-y ↗
19. Prolonged antibiotic delivery from anodized nanotubular titanium using a co-precipitation drug loading method10.1002/jbm.b.31433 ↗
20. Validation and in vitro characterization of antibiotic-loaded bone cement release10.1016/S0378-5173(00)00520-2 ↗
21. Diameter of titanium nanotubes influences anti-bacterial efficacy10.1088/0957-4484/22/29/295102 ↗
22. Effect of heat treatment on the corrosion resistance of selective laser melted Ti6Al4V3Cu alloy10.1016/j.jmrt.2021.03.041 ↗