Silicon nitride (SiNx) coatings are currently under investigation as bearing surfaces for joint implants, due to their low wear rate and the good biocompatibility of both coatings and their potential wear debris. The aim of this study was to move further towards functional SiNx coatings by evaluating coatings deposited onto CoCrMo surfaces with a CrN interlayer, using different bias voltages and substrate rotations. Reactive direct current magnetron sputtering was used to coat CoCrMo discs with a CrN interlayer, followed by a SiNx top layer, which was deposited by reactive high-power impulse magnetron sputtering. The interlayer was deposited using negative bias voltages ranging between 100 and 900 V, and 1-fold or 3-fold substrate rotation. Scanning electron microscopy showed a dependence of coating morphology on substrate rotation. The N/Si ratio ranged from 1.10 to 1.25, as evaluated by X-ray photoelectron spectroscopy. Vertical scanning interferometry revealed that the coated, unpolished samples had a low average surface roughness between 16 and 33 nm. Rockwell indentations showed improved coating adhesion when a low bias voltage of 100 V was used to deposit the CrN interlayer. Wear tests performed in a reciprocating manner against Si3N4 balls showed specific wear rates lower than, or similar to that of CoCrMo. The study suggests that low negative bias voltages may contribute to a better performance of SiNx coatings in terms of adhesion. The low wear rates found in the current study support further development of silicon nitride-based coatings towards clinical application.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Metal and Thin Film Mechanics · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, Uppsala 752 37, Sweden
IHI Ionbond AG, Industriestrasse 211, Olten 4600, Switzerland
Thin Film Physics Division, Department of Physics, Chemistry and Biology (IFM), Linköping University, Linköping 581 83, Sweden
Funding
Seventh Framework Programme · Erasmus Mundus Programme · Swedish Government Strategic Research Area in Materials Science on Advanced Functional Materials at Linköping University
References (53)
Show source-provided references
1. Kärrholm, J., Lindahl, H., Malchau, H., Mohaddes, M., Rogmark, C., and Rolfson, O. (2015). Swedish Hip Arthroplasty Register Annual Report 2015, Swedish Hip Arthroplasty Register.
2. Sundberg, M., Lidgren, L., W-Dahl, A., and Robertsson, O. (2015). Swedish Knee Arthroplasty Register Annual Report 2015, Swedish Hip Arthroplasty Register.
3. Failure rates of stemmed metal-on-metal hip replacements10.1016/S0140-6736(12)61169-6 ↗
4. The operation of the century: Total hip replacement10.1016/S0140-6736(07)60457-7 ↗
5. Pettersson, M. (2015). Silicon Nitride for Total Hip Replacements. [Ph.D. Thesis, Uppsala University].
6. What are the current clinical issues in wear and tribocorrosion?10.1007/s11999-014-3610-1 ↗
7. Reasons for revision of first-generation highly cross-linked polyethylenes10.1016/j.arth.2010.04.018 ↗
8. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene10.1007/s11999-011-1872-4 ↗
9. Size of metallic and polyethylene debris particles in failed cemented total hip replacements10.1302/0301-620X.74B3.1587882 ↗
10. Metal-on-metal hip arthroplasty: A review of adverse reactions and patient management10.3390/jfb6030486 ↗
11. Detection and analysis of nanoparticles in patients: A critical review of the status quo of clinical nanotoxicology10.1016/j.biomaterials.2015.10.061 ↗
12. Surface modification on CoCrMo alloy to improve the adhesion strength of hydroxyapatite coating10.1016/j.proeng.2017.04.110 ↗
13. Mechanical, wear, corrosion and biological properties of arc deposited titanium nitride coatings10.1016/j.surfcoat.2018.03.019 ↗
14. Optimizing thickness of ceramic coatings on plastic components for orthopedic applications: A finite element analysis10.1016/j.msec.2015.08.067 ↗
15. Biotribology of a new bearing material combination in a rotating hinge knee articulation10.1016/j.actbio.2013.02.030 ↗
16. Availability of total knee arthroplasty implants for metal hypersensitivity patients10.5792/ksrr.16.018 ↗
17. Mechanical and tribological behavior of silicon nitride and silicon carbon nitride coatings for total joint replacements10.1016/j.jmbbm.2013.05.002 ↗
18. On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part I: Processing, microstructure, mechanical properties, cytotoxicity10.1007/s10856-008-3417-2 ↗
19. Fabrication and testing of silicon nitride bearings in total hip arthroplasty: Winner of the 2007 “HAP” PAUL award10.1016/j.arth.2008.01.300 ↗
20. Silicon nitride bioceramics in healthcare10.1111/ijac.12836 ↗
21. Dissolution behaviour of silicon nitride coatings for joint replacements10.1016/j.msec.2016.01.049 ↗
22. Morphology and dissolution rate of wear debris from silicon nitride coatings10.1021/acsbiomaterials.6b00133 ↗
23. A novel method for isolation and recovery of ceramic nanoparticles and metal wear debris from serum lubricants at ultra-low wear rates10.1016/j.actbio.2016.07.004 ↗
24. Performance of HIPIMS deposited CrN/NbN nanostructured coatings exposed to 650 °C in pure steam environment10.1016/j.matchemphys.2016.05.017 ↗
25. Structure and properties of high power impulse magnetron sputtering and DC magnetron sputtering CrN and TiN films deposited in an industrial scale unit10.1016/j.tsf.2010.05.062 ↗
26. Effect of bias voltage on TiAlSiN nanocomposite coatings deposited by HiPIMS10.1016/j.apsusc.2016.09.028 ↗
27. The ion energy distributions and ion flux composition from a high power impulse magnetron sputtering discharge10.1016/j.tsf.2006.04.051 ↗
28. Comparative wear under different conditions of surface-engineered metal-on-metal bearings for total hip arthroplasty10.1016/j.arth.2004.09.014 ↗
29. (2011). ASTM F799-11 Standard Specification for Cobalt-28Chromium-6Molybdenum Alloy Forgings for Surgical Implants (UNS R31537, R31538, R31539), ASTM International.
30. (2008). ISO 26443-2008 Fine Ceramics (Advanced Ceramics, Advanced Technical Ceramics) Rockwell Indentation Test for Evaluation of Adhesion of Ceramic Coatings, ISO.
31. (2018). ASTM F2094/F2094M-18a Standard Specification for Silicon Nitride Bearing Balls, ASTM International.
32. Fabrication and evaluation of SixNy coatings for total joint replacements10.1007/s10856-012-4625-3 ↗
33. (2011). ASTM F1537-11 Standard Specification for Wrought Cobalt-28Chromium-6Molybdenum Alloys for Surgical Implants (UNS R31537, UNS R31538, and UNS R31539), ASTM International.
34. Computational hip joint simulator for wear and heat generation10.1016/j.jbiomech.2006.12.005 ↗
35. Assessment of the applicability of the Hertzian contact theory to edge-loaded prosthetic hip bearings10.1016/j.jbiomech.2011.08.007 ↗
36. (2017). ASTM F732-17 Standard Test Method for Wear Testing of Polymeric Materials Used in Total Joint Prostheses, ASTM International.
37. Contact and rubbing of flat surfaces10.1063/1.1721448 ↗
38. (2012). ASTM F2033-12 Standard Specification for Total Hip Joint Prosthesis and Hip Endoprosthesis Bearing Surfaces Made of Metallic, Ceramic, and Polymeric Materials, ASTM International.
39. Influence of pulse frequency and bias on microstructure and mechanical properties of TiB2 coatings deposited by high power impulse magnetron sputtering10.1016/j.surfcoat.2016.06.086 ↗
40. Dependence of microstructure and hardness of TiAlN/VN hard coatings on the type of substrate rotation10.1016/j.vacuum.2011.07.052 ↗
41. High power pulsed magnetron sputtered CrNx films
42. SiNx coatings deposited by reactive high power impulse magnetron sputtering: Process parameters influencing the nitrogen content10.1021/acsami.6b05830 ↗
43. Tribological and corrosion testing of surface engineered surgical grade CoCrMo alloy10.1016/j.wear.2010.12.062 ↗
44. Laser processed calcium phosphate reinforced CoCrMo for load-bearing applications: Processing and wear induced damage evaluation10.1016/j.actbio.2017.11.022 ↗
45. A review and a fundamental theory of silicon nitride tribochemistry10.1016/j.wear.2012.03.001 ↗
46. López, A., Filho, L.C., Cogrel, M., Engqvist, H., Schmidt, S., Högberg, H., and Persson, C. (2018, January 26–29). Morphology and adhesion of silicon nitride coatings upon soaking in fetal bovine serum. Proceedings of the 15th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering and the 3rd Conference on Imaging and Visualization, Lisbon, Portugal.
47. Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device10.1002/1097-4636(20011215)57:4<506::AID-JBM1196>3.0.CO;2-H ↗
48. In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements10.1243/095441103765212659 ↗
49. Surface engineering: A low wearing solution for metal-on-metal hip surface replacements10.1002/jbm.b.31317 ↗
50. Orthopedic applications of silicon nitride ceramics10.1016/j.actbio.2012.04.031 ↗
51. Evaluation of silicon nitride as a wear resistant and resorbable alternative for total hip joint replacement10.4161/biom.20710 ↗
52. In vitro tribological and biocompatibility evaluation of sintered silicon nitride10.1016/j.matlet.2017.10.061 ↗
53. Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses10.1016/j.arth.2009.10.019 ↗