journal article·2018-08-16Open access

Hemin-Modified SnO2/Metglas Electrodes for the Simultaneous Electrochemical and Magnetoelastic Sensing of H2O2

Georgios Samourgkanidis, Pavlos Nikolaou, Andreas Gkovosdis-Louvaris, Elias Sakellis, Ioanna Maria Blana, Emmanuel Topoglidis

Coatings· Volume 8· Issue 8

Abstract

In this work, we present a simple and efficient method for the preparation of hemin-modified SnO2 films on Metglas ribbon substrates for the development of a sensitive magneto-electrochemical sensor for the determination of H2O2. The SnO2 films were prepared at low temperatures, using a simple hydrothermal method, compatible with the Metglas surface. The SnO2 film layer was fully characterized by X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), photoluminescence (PL) and Fourier Transform-Infrared spectroscopy (FT-IR). The properties of the films enable a high hemin loading to be achieved in a stable and functional way. The Hemin/SnO2-Metglas system was simultaneously used as a working electrode (WE) for cyclic voltammetry (CV) measurements and as a magnetoelastic sensor excited by external coils, which drive it to resonance and interrogate it. The CV scans reveal direct reduction and oxidation of the immobilized hemin, as well as good electrocatalytic response for the reduction of H2O2. In addition, the magnetoelastic resonance (MR) technique allows the detection of any mass change during the electroreduction of H2O2 by the immobilized hemin on the Metglas surface. The experimental results revealed a mass increase on the sensor during the redox reaction, which was calculated to be 767 ng/μM. This behavior was not detected during the control experiment, where only the NaH2PO4 solution was present. The following results also showed a sensitive electrochemical sensor response linearly proportional to the concentration of H2O2 in the range 1 × 10−6–72 × 10−6 M, with a correlation coefficient of 0.987 and detection limit of 1.6 × 10−7 M. Moreover, the Hemin/SnO2-Metglas displayed a rapid response (30 s) to H2O2 and exhibits good stability, reproducibility and selectivity.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Analytical Chemistry and Sensors · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemical Engineering, University of Patras, Patras 26504, Greece

Department of Materials Science, University of Patras, Patras 26504, Greece

Institute of Nanoscience and Nanotechnology, National Center of Scientific Research, Athens 15310, Greece

References (59)

Show source-provided references
1. Determination of hydrogen peroxide concentration in antiseptic solutions using portable near-infrared system10.1016/S0731-7085(03)00420-5 ↗
2. Biosensor Based on Ultrasmall MoS2 Nanoparticles for Electrochemical Detection of H2O2 Released by Cells at the Nanomolar Level10.1021/ac402114c ↗
3. A Facile One-Pot Synthesis of Copper Sulfide-Decorated Reduced Graphene Oxide Composites for Enhanced Detecting of H2O2 in Biological Environments10.1021/ac400659u ↗
4. Rapid and selective determination of hydrogen peroxide residues in milk by batch injection analysis with amperometric detection10.1016/j.foodchem.2012.01.003 ↗
5. LakeNet: An Integrated Sensor Network for Environmental Sensing in Lakes10.1089/ees.2006.0044 ↗
6. Determination of hydrogen peroxide by high-performance liquid chromatography with a cation-exchange resin gel column and electrochemical detector10.2116/analsci.15.481 ↗
7. Oxo [5, 10, 15, 20-tetra(4-pyridyl) porphyrinato] titanium (IV): An ultra-high sensitivity spectrophotometric reagent for hydrogen peroxide10.1039/an9921701781 ↗
8. A luminescence-based probe for sensitive detection of hydrogen peroxide in seconds10.1016/j.aca.2014.05.019 ↗
9. H2O2 triggered sol–gel transition used for visual detection of glucose10.1039/c2cc17872a ↗
10. Sun, J., Li, C., Qi, Y., Guo, S., and Liang, X. (2016). Optimizing Colorimetric Assay Based on V2O5 Nanozymes for Sensitive Detection of H2O2 and Glucose. Sensors, 16.10.3390/s16040584 ↗
11. Single-Molecule Detection of H2O2 Mediating Angiogenic Redox Signaling on Fluorescent Single-Walled Carbon Nanotube Array10.1021/nn201904t ↗
12. A novel electrochemical hydrogen peroxide biosensor based on hemoglobin capped gold nanoclusters-chitosan composite10.1039/C5RA09216G ↗
13. A hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin in Hb-Ag sol films10.1016/j.snb.2007.10.048 ↗
14. Direct electrochemistry and electrocatalysis of Hemoglobin/ZnO-Chitosan/nano-Au modified glassy carbon electrode10.1002/elan.200804337 ↗
15. Electrochemical sensors and biosensors based on nanomaterials and nanostructures10.1021/ac5039863 ↗
16. Liu, X., Ma, T., Pinna, N., and Zhang, J. (2017). Two-dimensional nanostructured materials for gas sensing. Adv. Funct. Mater., 1702168.10.1002/adfm.201702168 ↗
17. Nanostructured material for room-temperature gas sensors10.1002/adma.201503825 ↗
18. A review on chemiresistive room temperature gas sensors based on metal oxide nanostructures, graphene and 2D transition metal dichalcogenides10.1007/s00604-018-2750-5 ↗
19. Highly Sensitive Graphene-Pt Nanocomposites Amperometric Biosensor and Its Application in Living Cell H2O2 Detection10.1021/ac5009699 ↗
20. Hemin on graphene nanosheets functionalized with flower-like MnO2 and hollow AuPd for the electrochemical sensing lead ion based on the specific DNAzyme10.1016/j.bios.2016.07.111 ↗
21. Cu-Hemin Metal Organic Frameworks Chitosan Reduced Graphene Oxide Nanocomposites with Peroxidase-Like Bioactivity for Electrochemical Sensing10.1016/j.electacta.2016.07.162 ↗
22. A novel H2O2 biosensor based on Fe3O4–Au magnetic nanoparticles coated horseradish peroxidase and graphene sheets–Nafion film modified screen-printed carbon electrode10.1016/j.electacta.2013.08.011 ↗
23. Ternary Composite of Hemin, Gold Nanoparticles and Graphene for Highly Efficient Decomposition of Hydrogen Peroxide10.1038/srep03285 ↗
24. Pd nanoparticle-modified electrodes for nonenzymatic hydrogen peroxide detection10.1186/s11671-015-1021-1 ↗
25. Carbon nanoparticles-induced formation of polyaniline nanofibers and their subsequent decoration with Ag nanoparticles for nonenzymatic H2O2 detection10.1134/S1023193513020043 ↗
26. Novel photoelectrochemical hydrogen peroxide sensor based on hemin sensitized nanoporous NiO based photocathode10.1016/j.jelechem.2015.07.051 ↗
27. Dispersed CuO nanoparticles on a silicon nanowire for improved performance of nanoenzymatic H2O2 detection10.1021/am501799w ↗
28. Hemin Modified TiO2 Nanoparticles with Enhanced Photoelectrocatalytic Activity for Electrochemical and Photoelectrochemical Sensing10.1149/2.1291609jes ↗
29. A novel water-soluble sulfonated porphyrin fluorescence sensor for sensitive assays of H2O2 and glucose10.1039/C4AN02142H ↗
30. Synergistic-Effect-Controlled Tetraoctylammonium Bromide/Multi-Walled Carbon Nanotube@Hemin Hybrid Material for Construction of Electrochemical Sensor10.1149/2.1431704jes ↗
31. One–pot fabrication of Hemin-N-C composite with enhanced electrocatalysis and application of H2O2 sensing10.1016/j.electacta.2017.12.111 ↗
32. Panagiotopoulos, A., Gkouma, A., Vassi, A., Johnson, C.J., Cass, A.E.G., and Topoglidis, E. (2018). Hemin modified SnO2 films on ITO-PET with enhanced activity for electrochemical sensing. Electroanalysis, in Press.10.1002/elan.201800188 ↗
33. Hemin-adsorbed carbon felt for sensitive and rapid flow-amperometric detection of dissolved oxygen10.1007/s00604-013-1057-9 ↗
34. Biomimetic sensor based on hemin/carbon nanotubes/chitosan modified microelectrode for nitric oxide measurement in the brain10.1016/j.bios.2013.01.015 ↗
35. Amperometric determination of nitrite using natural fibers as template for titanium dioxide nanotubes with immobilized hemin as electron transfer mediator10.1007/s00604-018-2715-8 ↗
36. Stable hemin embedded in Nafion films for the catalytic reduction of trichloroacetic acid under hydrodynamic conditions10.1016/j.elecom.2005.05.007 ↗
37. Ferrous hemin oxidation by organic halides at nanocrystalline TiO2 interfaces10.1021/nl034353i ↗
38. Hemin immobilized into metal-organic frameworks as electrochemical biosensor for 2,4,6-trichlorophenol10.1088/1361-6528/aaa26e ↗
39. An amperometric sensor based on hemin adsorbed on silica gel modified with titanium oxide for electrocatalytic reduction and quantification of artemisinin10.1016/j.talanta.2008.07.043 ↗
40. Hemin functionalized graphene nanosheets-based dual biosensor platforms for hydrogen peroxide and glucose10.1016/j.snb.2011.07.050 ↗
41. Polypyrrole nanoparticles as promising enzyme mimics for sensitive hydrogen peroxide detection10.1039/C4CC00328D ↗
42. Polyoxometalates as peroxidase mimetics and their applications in H2O2 and glucose detection10.1016/j.bios.2012.03.031 ↗
43. Sagasti, A., Bouropoulos, N., Kouzoudis, D., Panagiotopoulos, A., Topoglidis, E., and Gutierrez, J. (2017). Nanostructured ZnO in a Metglas/ZnO/Hemoglobin modified electrode to detect the oxidation of Hemoglobin simultaneously by cyclic voltammetry and magnetoelastic resonance. Materials, 10.10.3390/ma10080849 ↗
44. Immobilization and bioelectrochemistry of proteins on nanoporous TiO2 and ZnO films10.1016/S0022-0728(01)00673-8 ↗
45. Adsorption and redox thermodynamics of strongly adsorbed cytochrome c on tin oxide electrodes10.1021/j100384a048 ↗
46. Mass load distribution dependence of mass sensitivity of magnetoelastic sensors under different resonance modes10.3390/s150820267 ↗
47. Nonuniform mass detection using magnetostrictive biosensors operating under multiple harmonic resonance modes10.1063/1.3431523 ↗
48. Metallic glasses and sensing applications10.1088/0022-3735/21/12/002 ↗
49. Magnetomechanical coupling and permeability in transversely annealed Metglas 2605 alloys10.1109/TMAG.1981.1061735 ↗
50. Direct Electrochemistry and Nitric Oxide Interaction of Heme Proteins Adsorbed on Nanocrystalline Tin Oxide Electrodes10.1021/la034466h ↗
51. Joint Committee on Powder Diffraction Standards (JCPDS) Card No. 41-1445 for SnO2, International Center for Diffraction Data.
52. Magnetic properties of Mn-doped SnO2 thin films prepared by the Sol–Gel dip coating method for dilute magnetic semiconductors10.1111/jace.13084 ↗
53. Photoluminescence and Defects in Ultrathin SnO2 Films10.1063/1.4791401 ↗
54. Graphene–SnO2 composites for highly efficient photocatalytic degradation of methylene blue under sunlight10.1088/0957-4484/23/35/355705 ↗
55. Hemin-coupled iron (III)-hydroxide nanoparticles show increased uptake in Caco-2 cells10.1111/j.2042-7158.2011.01356.x ↗
56. Thermal and electrochemical properties of cobalt containing Finemet type alloys10.1016/j.electacta.2003.08.012 ↗
57. General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems10.1016/S0022-0728(79)80075-3 ↗
58. A novel electrochemical biosensor based on the hemin-graphene nano-sheets and gold nano-particles hybrid film for the analysis of hydrogen peroxide10.1016/j.aca.2013.06.016 ↗
59. Glassy carbon electrode modified with hemin and new melamine compounds for H2O2 amperometric detection10.1007/s10008-016-3298-0 ↗