journal article·2021-06-22Open access

Restraining Surface Charge Accumulation and Enhancing Surface Flashover Voltage through Dielectric Coating

Jixing Sun, Sibo Song, Xiyu Li, Yunlong Lv, Jiayi Ren, Fan Ding, Changwang Guo

Coatings· Volume 11· Issue 7

Abstract

A conductive metallic particle in a gas-insulated metal-enclosed system can charge through conduction or induction and move between electrodes or on insulating surfaces, which may lead to breakdown and flashover. The charge on the metallic particle and the charging time vary depending on the spatial electric field intensity, the particle shape, and the electrode surface coating. The charged metallic particle can move between the electrodes under the influence of the spatial electric field, and it can discharge and become electrically conductive when colliding with the electrodes, thus changing its charge. This process and its factors are mainly affected by the coating condition of the colliding electrode. In addition, the interface characteristics affect the particle when it is near the insulator. The charge transition process also changes due to the electric field strength and the particle charging state. This paper explores the impact of the coating material on particle charging characteristics, movement, and discharge. Particle charging, movement, and charge transfer in DC, AC, and superimposed electric fields are summarized. Furthermore, the effects of conductive particles on discharge characteristics are compared between coated and bare electrodes. The reviewed studies demonstrate that the coating can effectively reduce particle charge and thus the probability of discharge. The presented research results can provide theoretical support and data for studying charge transfer theory and design optimization in a gas-insulated system.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: High voltage insulation and dielectric phenomena · Aerosol Filtration and Electrostatic Precipitation · Power Transformer Diagnostics and Insulation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China

Funding

National Natural Science Foundation of China

References (58)

Show source-provided references
1. Study of charge accumulation on insulator surface in HVDC Gas-insulated switchgear
2. Novel HVDC spacers by adaptively controlling surface charges—Part II: Experiment10.1109/TDEI.2018.007056 ↗
3. Christodoulou, C.A., Vita, V., Mladenov, V., and Ekonomou, L. (2018). On the computation of the voltage distribution along the non-linear resistor of gapless metal oxide surge arresters. Energies, 11.10.3390/en11113046 ↗
4. Insulation properties of highly pressurized dry air-effects of anodic oxide coating and surface roughness of electrodes on breakdown voltage10.1109/TDEI.2014.003836 ↗
5. Meijer, S., Smit, J.J., Gulski, E., and Girodet, A. (2002, January 6–10). Partial discharge early warning system in gas-insulated switchgear. Proceedings of the IEEE/PES Transmission and Distribution Conference and Exhibition, Yokohama, Japan.
6. Activity of Moving Metallic Particles in Prebreakdown State in GIS10.1109/94.590864 ↗
7. Charge cluster triggers unpredictable insulation surface flashover in pressurized SF6
8. Budiman, F.N., Khan, Y., and Al-Arainy, A.A. (2013, January 14). Estimation of particle initiated PD inception voltage around spacer in GIS. Proceedings of the 4th International Conference on Power Engineering, Energy and Electrical Drives, Itanbul, Turkey.10.1109/PowerEng.2013.6635662 ↗
9. Conducting particle motion and particle-initiated breakdown in dc electric field between diverging conducting plates in atmospheric air10.1109/94.752020 ↗
10. Comparison of ANN and finite element analysis simulation software for the calculation of the electric field around metal oxide surge arresters10.1016/j.epsr.2015.11.041 ↗
11. Ultrasonic characteristics and state recognition of moving metal particles in GIS under DC
12. Novel HVDC Spacers by Adaptively Controlling Surface Charges—Part I: Charge Transport and Control Strategy10.1109/TDEI.2018.007054 ↗
13. Motion analysis of spherical conducting particle in DC GIL considering the influence of inelastic random collisions and SF6/N2 gaseous mixture
14. The potentially neglected culprit of DC surface flashover: Electron migration under temperature gradients10.1038/s41598-017-03657-1 ↗
15. Gas–Solid interface charge characterisation techniques for HVDC GIS/GIL insulators10.1049/hve.2019.0289 ↗
16. El Bahy, M.M., Ward, S.A., Morsi, R., and Badawi, M. (2011, January 20). Particle-initiated breakdown in gas-insulated co-axial configuration. Proceedings of the 2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, Cancun, Mexico.10.1109/CEIDP.2011.6232758 ↗
17. Nanosecond surface discharge study by using dust figure techniques10.1063/1.1662414 ↗
18. Influence of tiny metal particles on charge accumulation phenomena of GIS model spacer in high-pressure SF6 gas10.1109/TDEI.2013.6633722 ↗
19. Motion of conducting particle near PTFE spacer under AC voltage
20. Particle trajectories and its charging behaviors: Effect of gas type and electric field10.1088/1361-6528/abce31 ↗
21. Research on Experiment and Simulation of Charged Metal Particle Collision Characteristic10.1109/TDEI.2016.7736877 ↗
22. Movement Characteristics of Ball Metallic Particle between Ball-Plane Electrodes under DC Voltage10.1109/TDEI.2018.006879 ↗
23. Force Acting on a Conducting Sphere in the Field of a Parallel Plane Condenser
24. Charge and force on a conducting sphere between two parallel electrodes10.1016/S0304-3886(02)00063-3 ↗
25. Experimental studies of free conducting wire particle behavior between nonparallel plane electrodes with AC voltages in air10.1109/TDEI.2003.1207467 ↗
26. Motion behavior and deactivation method of free-conducting particle around spacer between diverging conducting plates under DC voltage in atmospheric air10.1109/TDEI.2003.1207471 ↗
27. Mechanism analysis of the Electrode–Coating’s Impact on the particle-lifting under DC voltage
28. Charging mechanism of metallic conducting particle on a dielectrically coated electrode in gas insulated system
29. Development and evaluation of a Faraday cup electrometer for measuring and sampling atmospheric ions and charged aerosols10.1080/02726351.2014.952392 ↗
30. Theoretical and experimental studies for spherical free-conducting particle behavior between nonparallel plane electrodes with AC voltages in air10.1109/TDEI.2003.1207466 ↗
31. Runde, M., Aurud, T., Nokleby, J.E., Skyberg, B., Ljokelsoy, K., and Lundgaard, L.E. (1996, January 16). Risk assessment basis of moving particles in gas insulated substations. Proceedings of the 1996 Transmission and Distribution Conference and Exposition, Los Angeles, CA, USA.
32. Particles in GIS characterization from acoustic signatures10.1109/94.971466 ↗
33. Uniform Field Charge on a Conducting Particle10.1109/TDEI.2009.5211870 ↗
34. Experimental study of accelerating surface charge dissipation on polymer treated by repetitively pulsed discharge plasmas
35. Charge distribution measurement on a truncated cone spacer under DC voltage10.1109/TDEI.2004.1387815 ↗
36. Nojima, K., Zhang, X., Sato, M., Yasuoka, T., Shiiki, M., Takei, M., and Boggs, S.A. (2014, January 5). Forces affecting metallic particle motion in GIS. Proceedings of the 2014 International Symposium on Electrical Insulating Materials, Niigata, Japan.10.1109/ISEIM.2014.6870738 ↗
37. Effect of electrode surface coating on charge injection
38. Impact of Linear Metal Particle on Surface Charge Accumulation of Post Insulator within DC GIL
39. Metallic particle dynamics in a single phase gas insulated busduct with coated electrodes under lightning impulse superimposed on power frequency voltage10.1002/etep.351 ↗
40. Free Conducting Particles in Compressed Gas Insulation
41. Dvnamic Analysis of Motion of Spherical Metallic Particles in Non-Uniform Electric Field10.1109/94.993746 ↗
42. Motion analysis of spherical free conductive particles under non-uniform DC electric field in GIS
43. Forces ad charges of paticles in contact with a electrode under the influence of an electric feld
44. Sakai, K., Abella, D.L., and Suehiro, J. (2000, January 15). Mode of free-conducting particle motion and particle-triggered breakdown mechanism in non-uniform field gaps. Proceedings of the 2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132), Victoria, BC, Canada.
45. Wang, J. (2017). Research on the Charged Motion Mechanism and Treatment Method of DC GIL Metal Particles. [Ph.D. Thesis, North China Electric Power University]. (In Chinese).
46. Characteristics of Acoustic Signal from Free Moving Metallic Particles in Gas Insulated Switchgear
47. Farish, O., and Al-Bawy, I. (1990, January 8). Charge deposition and insulator flashover in SF6 under impulse voltages. Proceedings of the IEE Colloquium on Charging and Tracking of Insulators in Gaseous and Vacuum Environments, London, UK.10.1049/ip-a-3.1991.0012 ↗
48. Motion of free conducting particles in SF6 insulated systems under dc switching voltages10.1109/94.300229 ↗
49. A High-Frequency Circuit Model of a Potential Transformer for the Very Fast Transient Simulation in GIS10.1109/TPWRD.2008.2002961 ↗
50. Improved Silicone Rubbers for the Use as Housing Material in Composite Insulators10.1109/TDEI.2012.6148520 ↗
51. Dielectric characteristics of spin-coated dielectric films using on-wafer parallel-plate capacitors at microwave frequencies
52. Envelope analysis and defects identification of Partial discharge UHF signals in GIS
53. Influence of contact potential difference and electric potential on the microhardness of metals10.1134/S1063783409060092 ↗
54. The control mechanism of surface traps on surface charge behavior in alumina-filled epoxy composites10.1088/0022-3727/49/44/445304 ↗
55. Evolution phenomena and features of surface partial discharge initiated by immobilized metal particles on GIS insulators
56. Effect of Metallic Particles in DC GIL on Surface Charge Accumulation of Insulators
57. Surface charge migration and dc surface flashover of surface-modified epoxy-based insulators
58. HVDC gas insulated apparatus: Electric field specificity and insulation design concept10.1109/57.995392 ↗