Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements
Source abstract
Abstract
Electrocardiogram (ECG) signals are often measured for medical purposes and in sports. While common Ag/AgCl glued gel electrodes enable good electrode skin contact, even during movements, they are not comfortable and can irritate the skin during long-term measurements. A possible alternative is textile electrodes, which have been investigated extensively during the last years. These electrodes, however, are usually not able to provide reliable, constant skin contact, resulting in reduced signal quality. Another important problem is the modification of the electrode surface due to washing or abrasion, which may impede the long-term use of such textile electrodes. Here, we report a study of washing and abrasion resistance of different ECG electrodes based on an isolating woven fabric with conductive embroidery and two conductive coatings, showing unexpectedly high abrasion resistance of the silver-coated yarn and optimum ECG signal quality for an additional coating with a conductive silicone rubber. Sheet resistances of the as-prepared electrodes were in the range of 20–30 Ω, which was increased to the range of 25–40 Ω after five washing cycles and up to approximately 50 Ω after Martindale abrasion tests. ECG measurements during different movements revealed reduced motion artifacts for the electrodes with conductive silicone rubber as compared to glued electrodes, suggesting that electronic filtering of such noise may even be easier for textile electrodes than for commercial electrodes.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Muscle activation and electromyography studies · Non-Invasive Vital Sign Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Textile and Fashion, Polytechnic University of Tirana, 1019 Tirana, Albania
Faculty of Engineering and Mathematics, Bielefeld University of Applied Sciences and Arts, 33619 Bielefeld, Germany
Virtual Institute of Applied Research on Advanced Materials (VIARAM)
Funding
Polytechnic University of Tirana · Deutsche Forschungsgemeinschaft
References (32)
Show source-provided references
1. Cardiopulmonary monitoring by textile electrodes without subject-awareness of being monitored10.1007/BF02510978 ↗
2. Surface modification of textile electrodes to improve electrocardiography signals in wearable smart garment10.1007/s10854-019-02047-9 ↗
3. Vidhya, C.M., Maithani, Y., and Singh, J.P. (2023). Recent Advances and Challenges in Textile Electrodes for Wearable Biopotential Signal Monitoring: A Comprehensive Review. Biosensors, 13.10.3390/bios13070679 ↗
4. Ritchie, H., and Roser, M. (2023, August 01). Causes of Death. Our World in Data 2018. Available online: https://ourworldindata.org/causes-of-death.
5. The leading causes of death in the US for 202010.1001/jama.2021.5469 ↗
6. ECG interpretation skill acquisition: A review of learning, teaching and assessment10.1016/j.jelectrocard.2019.03.010 ↗
7. Development of underwear with integrated 12 channel ECG for men and women10.1515/aut-2017-0008 ↗
8. Bouwstra, S., Chen, W., Bambang Oetomo, S., Feijs, L.M.G., and Cluitmans, P.J.M. (September, January 30). Designing for reliable textile neonatal ECG monitoring using multi-sensor recordings. Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA.10.1109/IEMBS.2011.6090690 ↗
9. Knitted ECG Electrodes in Relaxed Fitting Garments10.1109/JSEN.2023.3236723 ↗
10. An, X., and Stylios, G.K. (2018). A hybrid textile electrode for electrocardiogram (ECG) measurement and motion tracking. Materials, 11.10.3390/ma11101887 ↗
11. Investigating the performance of dry textile electrodes for wearable end-uses10.1080/00405000.2018.1508799 ↗
12. Nigusse, A.B., Malengier, B., Mengistie, D.A., Tseghai, G.B., and van Langenhove, L. (2020). Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring. Sensors, 20.10.3390/s20216233 ↗
13. Euler, L., Guo, L., and Persson, N.-K. (2021). Textile Electrodes: Influence of Knitting Construction and Pressure on the Contact Impedance. Sensors, 21.10.3390/s21051578 ↗
14. Ravichandran, V., Ciesielska-Wrobel, I., Rumon, M.A., Solanki, D., and Mankodiva, K. (2023). Characterizing the Impedance Properties of Dry E-Textile Electrodes Based on Contact Force and Perspiration. Biosensors, 13.10.3390/bios13070728 ↗
15. Ankhili, A., Tao, X.Y., Cochrane, C., Koncar, V., Coulon, D., and Tarlet, J.-M. (2019). Ambulatory Evaluation of ECG Signals Obtained Using Washable Textile-Based Electrodes Made with Chemically Modified PEDOT:PSS. Sensors, 19.10.3390/s19020416 ↗
16. Graphene coated textile based highly flexible and washable sports bra for human health monitoring10.1016/j.matdes.2020.108792 ↗
17. Textile electrodes in capacitive signal sensing applications10.1016/j.measurement.2017.09.024 ↗
18. Development and wearer trial of ECG-garment with textile-based dry electrodes10.1016/j.sna.2021.112784 ↗
19. 50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes10.3390/textiles2020014 ↗
20. Ankhili, A., Tao, X.Y., Cochrane, C., Coulon, D., and Koncar, V. (2018). Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring. Materials, 11.10.3390/ma11020256 ↗
21. Arquilla, K., Webb, A.K., and Anderson, A.P. (2020). Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring. Sensors, 20.10.3390/s20041013 ↗
22. Conductive Polyester Fabrics with High Washability as Electrocardiogram Textile Electrodes10.1021/acsapm.1c01619 ↗
23. Textile electrodes for bioimpedance measuring
24. Kyosev, Y., Mahltig, B., and Schwarz-Pfeiffer, A. (2017). Narrow and Smart Textiles, Springer.10.1007/978-3-319-69050-6 ↗
25. Applications of Smart Clothing—A Brief Overview
26. (2002). Textiles–Determination of the Abrasion Resistance of Fabrics by the Martindale Method-Part 1: Martindale Abrasion Testing Apparatus (ISO 12947-1:1998+Cor. 1:2002) (Standard No. ISO 12947-1:1998).
27. (2023, August 05). Sparkfun/AD8232_Heart_Rate_Monitor. Available online: https://github.com/sparkfun/AD8232_Heart_Rate_Monitor.
28. Uz Zaman, S., Tao, X.Y., Cochrane, C., and Koncar, V. (2020). Understanding the Washing Damage to Textile ECG Dry Skin Electrodes, Embroidered and Fabric-Based; set up of Equivalent Laboratory Tests. Sensors, 20.10.3390/s20051272 ↗
29. Screen printed graphene electrodes on textile for wearable electrocardiogram monitoring10.1007/s00339-019-3006-x ↗
30. Performance and Signal Quality Analysis of Electrocardiogram Textile Electrodes for Smart Apparel Applications10.3389/felec.2021.685264 ↗
31. Tseghai, G.B., Malengier, B., Fante, K.A., Nigusse, A.B., Etana, B.B., and van Langenhove, L. (2020, January 16–19). PEDOT:PSS/PDMS-coated cotton fabric for ECG electrode. Proceedings of the 2020 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS), Manchester, UK.10.1109/FLEPS49123.2020.9239526 ↗
32. All organic graphene oxide and Poly (3,4-ethylene dioxythiophene)-Poly (styrene sulfonate) coated knitted textile fabrics for wearable electrocardiography (ECG) monitoring10.1016/j.synthmet.2020.116329 ↗