journal article·2023-01-04Open access

In Vitro Investigation of Corrosion Control of Magnesium with Degradable Polycaprolactone Coatings for Cardiovascular Grafts

Sara Knigge, Marc Mueller, Lara Fricke, Tobias Schilling, Birgit Glasmacher

Coatings· Volume 13· Issue 1

Abstract

Magnesium is a promising metal for resorbable cardiovascular implants due to its high biocompatibility, high corrosion tendency, and mechanical properties. However, adapting its corrosion rate to the physiological healing processes is required to ascertain a safe graft function. A protective polymeric layer is supposed to slow down the corrosion rate of magnesium. Additionally, coatings can improve the host’s tissue interaction with the implant by implementing the local delivery of antibiotic drugs and growth or cell adhesion factors. However, little is known about the interaction of polymer-based coatings, their degradation, and magnesium corrosion. This study examines the corrosion mechanism of magnesium protected by spin coatings and electrospun fiber coatings under physiological conditions. Pure magnesium specimens were coated with polycaprolactone (PCL). The corrosion of the coated magnesium was evaluated using an immersion test in simulated body fluid. Spin coatings provided efficient protection against corrosive attacks and a significantly lower corrosion rate by 75% compared to uncoated magnesium. In contrast, fiber coatings did not provide relevant corrosion protection. On the other hand, magnesium corrosion caused the accelerated degradation of the PCL layer. A reliable and safe implant function is vital, especially in cardiovascular applications. Magnesium coating, therefore, should be carried out with spin coatings.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Tissue Engineering and Regenerative Medicine · Electrospun Nanofibers in Biomedical Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Cardiothoracic, Transplantation, and Vascular Surgery, Hannover Medical School, 30625 Hannover, Germany

Institute for Multiphase Processes, Leibniz University Hannover, 30823 Garbsen, Germany

Funding

Leibniz University Hannover

References (48)

Show source-provided references
1. Biosafety and efficacy evaluation of a biodegradable magnesium-based drug-eluting stent in porcine coronary artery10.1038/s41598-021-86803-0 ↗
2. Comparison of a Bioresorbable, Magnesium-Based Sirolimus-Eluting Stent with a Permanent, Everolimus-Eluting Metallic Stent for Treating Patients with Acute Coronary Syndrome: The PRAGUE-22 Study10.1007/s10557-021-07258-z ↗
3. A prospective, nonrandomized, open-labeled pilot study investigating the use of magnesium in patients undergoing nonacute percutaneous coronary intervention with stent implantation10.1177/107424840300800304 ↗
4. Engineering of biodegradable magnesium alloy scaffolds to stabilize biological myocardial grafts10.1515/bmt-2016-0205 ↗
5. In vivo degradation of magnesium alloy LA63 scaffolds for temporary stabilization of biological myocardial grafts in a swine model10.1515/bmt-2012-0047 ↗
6. Schilling, T., Meyer, T., Brandes, G., Hartung, D., Tudorache, I., Nolte, I., Wacker, F., Hilfiker, A., Hoeffler, K., and Haverich, A. Left Ventricular Wall Reconstruction with Autologous Vascularized Gastric Graft in a Porcine Pilot Model. Eur. Surg. Res., 2022.10.1159/000522478 ↗
7. Left ventricular aneurysm: A new surgical approach10.1055/s-2007-1013899 ↗
8. Viable vascularized autologous patch for transmural myocardial reconstruction10.1016/j.ejcts.2009.02.038 ↗
9. Chemical surface alteration of biodegradable magnesium exposed to corrosion media10.1016/j.actbio.2011.03.004 ↗
10. Electrodeposition of hydroxyapatite coating on AZ91D magnesium alloy for biomaterial application10.1016/j.matlet.2008.02.048 ↗
11. Effect of a plasmaelectrolytic coating on the strength retention of in vivo and in vitro degraded magnesium implants10.1016/j.actbio.2012.08.047 ↗
12. In vivo degradation and tissue compatibility of ZK60 magnesium alloy with micro-arc oxidation coating in a transcortical model10.1016/j.msec.2013.05.023 ↗
13. Influence of electrospinning and dip-coating techniques on the degradation and cytocompatibility of Mg-based alloy10.1016/j.colsurfa.2012.12.009 ↗
14. Interaction between a high purity magnesium surface and PCL and PLA coatings during dynamic degradation10.1088/1748-6041/6/2/025005 ↗
15. A biodegradable polymer-based coating to control the performance of magnesium alloy orthopaedic implants10.1016/j.biomaterials.2009.11.111 ↗
16. Characteristics and cytocompatibility of biodegradable polymer film on magnesium by spin coating10.1016/j.colsurfb.2011.12.009 ↗
17. Dipyridamole embedded in Polycaprolactone fibers prepared by coaxial electrospinning as a novel drug delivery system10.1016/j.jddst.2015.07.001 ↗
18. A biodegradable nanofiber scaffold by electrospinning and its potential for bone tissue engineering10.1016/S0142-9612(02)00635-X ↗
19. Cell infiltration and growth in a low density, uncompressed three-dimensional electrospun nanofibrous scaffold10.1016/j.biomaterials.2010.10.056 ↗
20. Electrospun cellular microenvironments: Understanding controlled release and scaffold structure10.1016/j.addr.2010.12.002 ↗
21. Electrospun vascular grafts with anti-kinking properties
22. Impact of setup orientation on blend electrospinning of poly-ε-caprolactone-gelatin scaffolds for vascular tissue engineering10.1177/0391398818803478 ↗
23. Electrochemical investigations of magnesium in DMEM with biodegradable polycaprolactone coating as corrosion barrier10.1016/j.apsusc.2013.05.115 ↗
24. Comparison between three in vitro methods to measure magnesium degradation and their suitability for predicting in vivo degradation10.1177/0391398818772777 ↗
25. Preparation and assessment of revised simulated body fluids10.1002/jbm.a.10482 ↗
26. Nidadavolu, E.P.S., Feyerabend, F., Ebel, T., Willumeit-Römer, R., and Dahms, M. (2016). On the Determination of Magnesium Degradation Rates under Physiological Conditions. Materials, 9.10.3390/ma9080627 ↗
27. (2017). Biologische Beurteilung von Medizinprodukten—Teil 1: Beurteilung und Prüfungen im Rahmen eines Risikomanagementsystems (Standard No. DIN EN ISO 10993-1:2017-04).
28. Evaluation of polycaprolactone—poly-D,L-lactide copolymer as biomaterial for breast tissue engineering10.1002/pi.5181 ↗
29. Fricke, D., Becker, A., Jütte, L., Bode, M., de Cassan, D., Wollweber, M., Glasmacher, B., and Roth, B. (2019). Mueller Matrix Measurement of Electrospun Fiber Scaffolds for Tissue Engineering. Polymers, 11.10.3390/polym11122062 ↗
30. Raman spectroscopy and the material study of nanocomposite membranes from poly(ε-caprolactone) with biocompatibility testing in osteoblast-like cells10.1039/C4AN02284J ↗
31. The measurement of the crystallinity of polymers by DSC10.1016/S0032-3861(02)00235-5 ↗
32. Blending chitosan-g-poly(caprolactone) with poly(caprolactone) by electrospinning to produce functional fiber mats for tissue engineering applications10.1002/app.48650 ↗
33. Characterization of tissue response and in vivo degradation of cholecyst-derived extracellular matrix10.1021/bm700560k ↗
34. Endogenous myocardial angiogenesis and revascularization using a gastric submucosal patch10.1016/S0003-4975(02)04708-2 ↗
35. The use of extracellular matrix as an inductive scaffold for the partial replacement of functional myocardium10.3727/000000006783982368 ↗
36. Tissue regeneration observed in a porous acellular bovine pericardium used to repair a myocardial defect in the right ventricle of a rat model10.1016/j.jtcvs.2005.04.007 ↗
37. Protective coatings on magnesium and its alloys—a critical review10.1016/S0925-8388(01)01899-0 ↗
38. Corrosion protection and improved cytocompatibility of biodegradable polymeric layer-by-layer coatings on AZ31 magnesium alloys10.1016/j.actbio.2013.05.010 ↗
39. Biomedical coatings on magnesium alloys—a review10.1016/j.actbio.2012.04.012 ↗
40. Plasma Modification of PCL Porous Scaffolds Fabricated by Solvent-Casting/Particulate-Leaching for Tissue Engineering10.1002/ppap.201300149 ↗
41. Electrochemical behavior of polypyrrole-coated AZ31 alloy modified by fluoride anions10.1007/s10008-016-3422-1 ↗
42. Six bioabsorbable polymers: In vitro acute toxicity of accumulated degradation products10.1002/jab.770050208 ↗
43. Determining conformational order and crystallinity in polycaprolactone via Raman spectroscopy10.1016/j.polymer.2017.04.006 ↗
44. Polyurethane elastomer biostability10.1177/088532829500900402 ↗
45. Autooxidative Degradation of Implanted Polyether Polyurethane Devices10.1177/088532828600100302 ↗
46. Myocardial tissue engineering: A review10.1002/term.46 ↗
47. Immobilisation of cell-binding peptides on poly-ε-caprolactone (PCL) films: A comparative XPS study of two chemical surface functionalisation methods10.1002/sia.5396 ↗
48. Boffito, M., Di Meglio, F., Mozetic, P., Giannitelli, S.M., Carmagnola, I., Castaldo, C., Nurzynska, D., Sacco, A.M., Miraglia, R., and Montagnani, S. (2018). Surface functionalization of polyurethane scaffolds mimicking the myocardial microenvironment to support cardiac primitive cells. PLoS ONE, 13.10.1371/journal.pone.0199896 ↗