SEM-EDX Analysis of Metal Particles Deposition from Surgical Burs after Implant Guided Surgery Procedures
Source abstract
Abstract
The preparation of the implant site in guided surgery procedure takes place without irrigation, which could lead to increased friction of the drills with the formation and release of debris or metal particles. The presence of metal particles in the peri-implant tissue could represent a trigger for macrophage activity, bone resorption processes, and consequent implant loss. According to the guided surgical protocol, the study aimed to evaluate the presence of metal particles deposited during implant site preparation. Twenty-five adult porcine ribs from the same adult individual were chosen due to their trabecular bone structure, similar to facial bones. The samples were all 8 cm (length) × 3 cm (depth) × 2 cm (width) and were further subdivided to obtain 50 elements of 4 cm × 3 cm × 2 cm. Plexiglass was used to create structures such as surgical guides so that their function could be mimicked, and the guided implant site preparation sequence could be performed with them. The drill kit used in this study is a guided surgery drill kit characterized by high wear resistance, high yield strength, and good corrosion resistance. This same kit was used 50 times in this way to prepare 50 different implant sites and evaluated at different edges and number of preparation (T0-neutral edge, T1-1 full preparation, T2-10, T3-20, T4-30, T5-40, and T6-50) by SEM-EDX to assess the presence of any metal deposition. The presence of metal residues in the implant site increased according to the cycles of use of the drills. We have observed that in the first three groups, there is no presence of metals. This is evident in groups T3 and T4. Finally, the presence of metal residues becomes significant in the study’s last two groups of samples. The study highlighted how the lack of irrigation in the work site leads the deposition of metal particles and in addition to a reduction in the efficiency of the drills, resulting in less precise cutting, altering the shape of the prepared site, and, lastly, reducing the primary stability of the implants.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Life, Health and Environmental Sciences, University of L’Aquila, 67100 L’Aquila, Italy
Department of Oral and Maxillo-Facial Sciences, “Sapienza” University of Rome, 00185 Rome, Italy
Center of Microscopy, University of L’Aquila, 67100 L’Aquila, Italy
References (37)
Show source-provided references
1. Implant success, survival, and failure: The International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference10.1097/ID.0b013e3181676059 ↗
2. Titanium as a reconstruction and implant material in dentistry: Advantages and pitfalls10.3390/ma5091528 ↗
3. Scanning electron microscopy and microbiological approaches for the evaluation of salivary microorganisms behaviour on anatase titanium surfaces: In vitro study10.1016/j.morpho.2017.12.001 ↗
4. Commercial oral hygiene products and implant collar surfaces: Scanning electron microscopy observations
5. Bernardi, S., Bianchi, S., Tomei, A.R., Continenza, M.A., and Macchiarelli, G. (2019). Microbiological and SEM-EDS evaluation of titanium surfaces exposed to periodontal gel: In vitro study. Materials, 12.10.3390/ma12091448 ↗
6. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: A study of drill durability
7. Does the instrument used for the implant site preparation influence the bone–implant interface? A systematic review of clinical and animal studies10.1016/j.ijom.2018.04.005 ↗
8. Effects of bur wear during implant site preparation: An in vitro study10.1177/039463200702001s06 ↗
9. Arthroscopic surgical tools: A source of metal particles and possible joint damage10.1016/j.arthro.2013.05.030 ↗
10. Titanium particles: An emerging risk factor for peri-implant bone loss10.1016/j.sdentj.2019.09.008 ↗
11. Cytotoxic effects of submicron- and nano-scale titanium debris released from dental implants: An integrative review10.1007/s00784-021-03785-z ↗
12. Release of metal ions from dental implant materials in vivo: Determination of Al, Co, Cr, Mo, Ni, V, and Ti in organ tissue10.1002/jbm.820251204 ↗
13. Particulate debris from a titanium metal prosthesis induces genomic instability in primary human fibroblast cells10.1038/sj.bjc.6600758 ↗
14. Wear particles, periprosthetic osteolysis and the immune system10.1016/j.biomaterials.2007.06.035 ↗
15. Metal-specific biomaterial accumulation in human peri-implant bone and bone marrow10.1002/advs.202000412 ↗
16. Surface damage on dental implants with release of loose particles after insertion into bone10.1111/cid.12167 ↗
17. In vitro evaluation of the effects of multiple oral factors on dental implants surfaces10.1563/aaid-joi-D-15-00165 ↗
18. A new classification scheme for periodontal and peri-implant diseases and conditions—Introduction and key changes from the 1999 classification10.1111/jcpe.12935 ↗
19. Microbiome and microbial biofilm profiles of peri-implantitis: A systematic review10.1902/jop.2017.170123 ↗
20. Current concepts on the pathogenesis of peri-implantitis: A narrative review10.1055/s-0040-1721903 ↗
21. Di Murro, B., Moretti, M., De Smaele, E., Letizia, C., Lubrano, C., Passarelli, P.C., D’Addona, A., Pompa, G., and Papi, P. (2021). Microbiological profiles of dental implants in metabolic syndrome patients: A case-control study. Antibiotics, 10.10.3390/antibiotics10040452 ↗
22. Conquest of a worldwide human disease: Particle-induced periprosthetic osteolysis
23. The role of value-based implants in orthopedic trauma10.1016/j.ocl.2018.05.005 ↗
24. Biological response to prosthetic debris10.5312/wjo.v6.i2.172 ↗
25. Is metal particle release associated with peri-implant bone destruction? An emerging concept10.1177/0022034517740560 ↗
26. Ozan, O., Şeker, E., Çakmak, G., Guo, X., and Yilmaz, B. (2021). Effect of guide sleeve material, region, diameter, and number of times drills were used on the material loss from sleeves and drills used for surgical guides: An in vitro study. Prosthet. Dent., 1–8.10.1016/j.prosdent.2020.12.036 ↗
27. Animal models for implant biomaterial research in bone: A review10.22203/eCM.v013a01 ↗
28. Bone character: Second vital implant criterion
29. Fluorimetric detection of a bacillus stearothermophilus spore-bound enzyme, alpha-d-glucosidase, for rapid indication of flash sterilization failure10.1128/aem.58.2.717-719.1992 ↗
30. The use of XPS, FTIR, SEM/EDX, contact angle, and AFM in the characterization of coatings10.1361/105994998770347747 ↗
31. Fourier transform infrared spectroscopic imaging of wear and corrosion products within joint capsuletissue from total hip replacements patients10.1002/jbm.b.34408 ↗
32. Long-term results of implants and implant-supported prostheses under systematic supportive implant therapy: A retrospective 25-year study10.1111/cid.12944 ↗
33. Potential release of in vivo trace metals from metallic medical implants in the human body: From ions to nanoparticles—A systematic anal–tical review10.1016/j.actbio.2014.02.027 ↗
34. Osteoimmunology10.1159/000098223 ↗
35. The biology of aseptic osteolysis10.1097/BLO.0b013e31804b4147 ↗
36. Titanium induced production of chemokines CCL17/TARC and CCL22/MDC in human osteoclasts and osteoblasts10.1002/jbm.a.32390 ↗
37. Effects of mechanical and thermal fatigue on dental drill performance