journal article·2022-02-01Open access

Differences in Metal Ions Released from Orthodontic Appliances in an In Vitro and In Vivo Setting

Vito Kovac, Borut Poljsak, Matic Bergant, Janez Scancar, Uros Mezeg, Jasmina Primozic

Coatings· Volume 12· Issue 2

Abstract

The aim was to assess the composition of released metal ions from fixed orthodontic appliances both in an in vitro and in vivo setting and to compare their quantities to evaluate any possible health risks associated with them. For the in vitro setting, a set of 24 as-received sterile SS brackets, 2 SS sterile archwires, and 2 NiTi sterile archwires were aged for 90 days in artificial saliva, and released metal ion concentrations were determined by inductively coupled plasma mass spectrometry (ICP-MS), using matrix-matched standards for calibration. For the in vivo setting, 15 brackets, 15 SS, and 15 NiTi archwires were retrieved after 90 days of intraoral exposure in 15 subjects. Debris composition on each part of the orthodontic appliance was assessed using scanning electron microscopy with energy dispersive spectroscopy (SEM/EDS). The present study evidenced a difference in the composition of released metal ions from fixed orthodontic appliances detected in an in vitro and in vivo setting. Generally, the relative content of metal ions was higher in the retrieved debris than that released in artificial saliva. The concentration of released metal ions from all tested alloys was below the upper recommended limit of daily intake; however, possible local effects in terms of hypersensitivity due to their accumulation in the debris cannot be excluded even with such concentrations.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Heavy Metal Exposure and Toxicity · Mercury impact and mitigation studies · Orthodontics and Dentofacial Orthopedics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Health Sciences, University of Ljubljana, SI-1000 Ljubljana, Slovenia

Department of Environmental Sciences, Jozef Stefan Institute, SI-1000 Ljubljana, Slovenia

Faculty of Medicine, University of Ljubljana, SI-1000 Ljubljana, Slovenia

Funding

Slovenian Research Agency

References (28)

Show source-provided references
1. Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro10.1016/0889-5406(93)70098-9 ↗
2. The effect of pH, fluoride and tribocorrosion on the surface properties of dental archwires10.1016/j.msec.2017.04.050 ↗
3. Absorption of nickel, chromium, and iron by the root surface of primary molars covered with stainless steel crowns10.1155/2010/326124 ↗
4. Release of metal ions from orthodontic appliances by in vitro studies: A systematic literature review10.1007/s12011-010-8670-9 ↗
5. Release of metal ions from fixed orthodontic appliance: An in vitro study in continuous flow system10.2319/113012-911.1 ↗
6. Hypersensitivity to conventional and to nickel-free orthodontic brackets10.1590/S1806-83242007000400003 ↗
7. Adverse reactions to orthodontic materials10.1111/adj.12473 ↗
8. Orthodontic appliances in relation to nickel hypersensitivity. A review10.1007/BF02716959 ↗
9. Metallic ions released from stainless steel, nickel-free, and titanium orthodontic alloys: Toxicity and DNA damage10.1016/j.ajodo.2011.02.021 ↗
10. In vivo study on metal release from fixed orthodontic appliances and DNA damage in oral mucosa cells10.1016/j.ajodo.2003.09.010 ↗
11. In vivo aging of orthodontic alloys: Implications for corrosion potential, nickel release, and biocompatibility
12. Kosec, T., Močnik, P., Mezeg, U., Legat, A., Ovsenik, M., Jenko, M., Grant, J.T., and Primožič, J. (2020). Tribocorrosive study of new and in vivo exposed nickel titanium and stainless steel orthodontic archwires. Coatings, 10.10.3390/coatings10030230 ↗
13. Kovac, V., Bergant, M., Scancar, J., Primozic, J., Jamnik, P., and Poljsak, B. (2021). Causation of Oxidative Stress and Defense Response of a Yeast Cell Model after Treatment with Orthodontic Alloys Consisting of Metal Ions. Antioxidants, 11.10.3390/antiox11010063 ↗
14. Release of nickel and chromium ions in the saliva of patients with fixed orthodontic appliance: An in-vivo study10.4103/0975-5950.168224 ↗
15. Ion release from orthodontic appliances10.1016/S0300-5712(98)00073-6 ↗
16. Effect of pH on in vitro biocompatibility of orthodontic miniscrew implants10.1186/2196-1042-14-15 ↗
17. Metal release from simulated fixed orthodontic appliances10.1067/mod.2001.117911 ↗
18. Nickel release from stainless steel and nickel titanium archwires—An in vitro study10.1016/j.jobcr.2016.06.001 ↗
19. Characterization and cytotoxicity of ions released from stainless steel and nickel-titanium orthodontic alloys10.1016/j.ajodo.2003.09.009 ↗
20. Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study10.4103/0975-7406.192032 ↗
21. Type of archwire and level of acidity: Effects on the release of metal ions from orthodontic appliances10.2319/083007-401.1 ↗
22. Dietary reference intakes: Vitamin A, vitamin K, arsenic, boron, chromium, copper, iodine, iron, manganese, molybdenum, nickel, silicon, vanadium, and zinc10.1016/S0002-8223(01)00078-5 ↗
23. Metal ion release from fixed orthodontic appliances—An in vivo study10.1093/ejo/cjq181 ↗
24. Evaluation of nickel ion release from various orthodontic arch wires: An in vitro study10.4103/2231-0762.130921 ↗
25. Release of metal ions from orthodontic appliances: An in vitro study10.1007/s12011-011-9233-4 ↗
26. Characterization of nickel-induced allergic contact stomatitis associated with fixed orthodontic appliances10.1016/j.ajodo.2005.03.002 ↗
27. Nickel Ion Release from Three Types of Nickel-titanium-based Orthodontic Archwires in the As-received State and After Oral Simulation
28. Kovac, V., Poljsak, B., Primozic, J., and Jamnik, P. (2020). Are Metal Ions That Make up Orthodontic Alloys Cytotoxic, and Do They Induce Oxidative Stress in a Yeast Cell Model?. Int. J. Mol. Sci., 21.10.3390/ijms21217993 ↗