Fibre Laser Treatment of Beta TNZT Titanium Alloys for Load-Bearing Implant Applications: Effects of Surface Physical and Chemical Features on Mesenchymal Stem Cell Response and Staphylococcus aureus Bacterial Attachment
Source abstract
Abstract
A mismatch in bone and implant elastic modulus can lead to aseptic loosening and ultimately implant failure. Selective elemental composition of titanium (Ti) alloys coupled with surface treatment can be used to improve osseointegration and reduce bacterial adhesion. The biocompatibility and antibacterial properties of Ti-35Nb-7Zr-6Ta (TNZT) using fibre laser surface treatment were assessed in this work, due to its excellent material properties (low Young’s modulus and non-toxicity) and the promising attributes of fibre laser treatment (very fast, non-contact, clean and only causes changes in surface without altering the bulk composition/microstructure). The TNZT surfaces in this study were treated in a high speed regime, specifically 100 and 200 mm/s, (or 6 and 12 m/min). Surface roughness and topography (WLI and SEM), chemical composition (SEM-EDX), microstructure (XRD) and chemistry (XPS) were investigated. The biocompatibility of the laser treated surfaces was evaluated using mesenchymal stem cells (MSCs) cultured in vitro at various time points to assess cell attachment (6, 24 and 48 h), proliferation (3, 7 and 14 days) and differentiation (7, 14 and 21 days). Antibacterial performance was also evaluated using Staphylococcus aureus (S. aureus) and Live/Dead staining. Sample groups included untreated base metal (BM), laser treated at 100 mm/s (LT100) and 200 mm/s (LT200). The results demonstrated that laser surface treatment creates a rougher (Ra value of BM is 199 nm, LT100 is 256 nm and LT200 is 232 nm), spiky surface (Rsk > 0 and Rku > 3) with homogenous elemental distribution and decreasing peak-to-peak distance between ripples (0.63 to 0.315 µm) as the scanning speed increases (p < 0.05), generating a surface with distinct micron and nano scale features. The improvement in cell spreading, formation of bone-like nodules (only seen on the laser treated samples) and subsequent four-fold reduction in bacterial attachment (p < 0.001) can be attributed to the features created through fibre laser treatment, making it an excellent choice for load bearing implant applications. Last but not least, the presence of TiN in the outermost surface oxide might also account for the improved biocompatibility and antibacterial performances of TNZT.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Mechanical and Aerospace Engineering, Queen’s University Belfast, Belfast BT9 5AH, UK
Department of Natural Sciences, University of Chester, Thornton Science Park, Chester CH2 4NU, UK
Centre for Experimental Medicine, Queen’s University Belfast, Belfast BT9 7BL, UK
School of Pharmacy, Queen’s University Belfast, Belfast BT9 7BL, UK
References (60)
Show source-provided references
1. National Joint Registry (2017). National Joint Registry for England, Wales and Northern Ireland 14th Annual Report 2017, Pad Creative Ltd.
2. Differentiation and function of osteoclasts10.2302/kjm.52.1 ↗
3. Aseptic loosening of total joint replacements: Mechanisms underlying osteolysis and potential therapies
4. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
5. Development of new metallic alloys for biomedical applications10.1016/j.actbio.2012.06.037 ↗
6. Design and mechanical properties of new beta type titanium alloys for implant materials10.1016/S0921-5093(97)00808-3 ↗
7. Effect of different Ti–6Al–4V surface treatments on osteoblasts behaviour10.1016/S0142-9612(01)00266-6 ↗
8. Characteristics of Biomedical Beta-Type Titanium Alloy Subjected to Coating10.2320/matertrans.MRA2007207 ↗
9. Biologically and Mechanically Biocompatible Titanium Alloys10.2320/matertrans.L-MRA2008828 ↗
10. State of the art and future directions of scaffold-based bone engineering from a biomaterials perspective10.1002/term.24 ↗
11. Biocompatibility of Ti-alloys for long-term implantation10.1016/j.jmbbm.2012.11.014 ↗
12. The significance of infection related to orthopedic devices and issues of antibiotic resistance10.1016/j.biomaterials.2005.11.044 ↗
13. Understanding the Mechanism of Bacterial Biofilms Resistance to Antimicrobial Agents10.2174/1874285801711010053 ↗
14. Bacterial adhesion on titanium nitride-coated and uncoated implants: An in vivo human study10.1563/1548-1336(2003)029<0080:BAOTNA>2.3.CO;2 ↗
15. Femtosecond laser surface texturing of titanium as a method to reduce the adhesion of Staphylococcus aureus and biofilm formation10.1016/j.apsusc.2015.10.102 ↗
16. Enhancing the antibacterial performance of orthopaedic implant materials by fibre laser surface engineering10.1016/j.apsusc.2017.01.233 ↗
17. Enhancement of wear and corrosion resistance of beta titanium alloy by laser gas alloying with nitrogen10.1016/j.apsusc.2016.01.091 ↗
18. Evaluation of titanium implants with surface modification by laser beam: Biomechanical study in rabbit tibias10.1590/S1806-83242009000200008 ↗
19. Human mesenchymal stem cell behavior on femtosecond laser-textured Ti-6Al-4V surfaces10.2217/nnm.15.19 ↗
20. Effect of laser peening on friction and wear behavior of medical Ti6Al4V alloy10.1016/j.optlastec.2018.08.005 ↗
21. Folkes, J.A. (1986). Laser Surface Melting and Alloying of Titanium Alloys. [Ph.D. Thesis, University of London].10.1007/978-94-009-4468-8_39 ↗
22. Enhancement of the Wear Resistance and Microhardness of Aluminum Alloy by Nd:YaG Laser Treatment10.1155/2014/842062 ↗
23. Effects of Laser Surface Melting on the Pitting Resistance of Sensitized Nitrogen-Bearing Type 316L Stainless Steel10.1361/105994998770347945 ↗
24. Surface modification and tribological behaviour of titanium and titanium alloys after YAG-laser treatments10.1016/S0257-8972(97)00653-1 ↗
25. Effect of laser surface remelting on the corrosion behavior of commercially pure titanium sheet10.1016/S0921-5093(02)00477-X ↗
26. National Joint Registry (2014). National Joint Registry for England, Wales and Northern Ireland 11th Annual Report 2014, Pad Creative Ltd.
27. National Joint Registry (2015). National Joint Registry for England, Wales and Northern Ireland 12th Annual Report 2015, Pad Creative Ltd.
28. National Joint Registry (2016). National Joint Registry for England, Wales and Northern Ireland 13th Annual Report 2016, Pad Creative Ltd.
29. National Joint Registry (2018). National Joint Registry for England, Wales and Northern Ireland 15th Annual Report 2018, Pad Creative Ltd.
30. How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up10.1016/S0140-6736(18)31665-9 ↗
31. Cellular responses to chemical and morphologic aspects of biomaterial surfaces. II. The biosynthetic and migratory response of bone cell populations10.1002/jbm.820290910 ↗
32. Leyens, C., and Peters, M. (2003). Titanium and Titanium Alloys: Fundamentals and Applications, Wiley-VCH.10.1002/3527602119 ↗
33. Increased bone formation to unstable nano rough titanium implants10.1111/j.1600-0501.2006.01308.x ↗
34. Sugioka, K., Meunier, M., and Pique, A. (2010). Laser Precision Microfabrication, Springer.10.1007/978-3-642-10523-4 ↗
35. A Review on Melt-Pool Characteristics in Laser Welding of Metals10.1155/2018/4920718 ↗
36. Fibre laser treatment of martensitic NiTi alloys for load-bearing implant applications: Effects of surface chemistry on inhibiting Staphylococcus aureus biofilm formation10.1016/j.surfcoat.2018.06.015 ↗
37. Microcolumn development on titanium by multipulse laser irradiation in nitrogen10.1557/JMR.2003.0311 ↗
38. Finite element simulation of laser surface treatments including convection in the melt pool10.1108/EUM0000000004031 ↗
39. Effect of material characteristics and/or surface topography on biofilm development10.1111/j.1600-0501.2006.01353.x ↗
40. Plaque formation on surface modified dental implants10.1034/j.1600-0501.2001.120601.x ↗
41. Brunello, G., Brun, P., Gardin, C., Ferroni, L., Bressan, E., Meneghello, R., Zavan, B., and Sivolella, S. (2018). Biocompatibility and antibacterial properties of zirconium nitride coating on titanium abutments: An in vitro study. PLoS ONE, 13.10.1371/journal.pone.0199591 ↗
42. XPS studies of nitrogen ion implanted zirconium and titanium10.1016/0368-2048(89)85018-2 ↗
43. Characteristics of Metals Used in Implants10.1089/end.1997.11.383 ↗
44. Di Silvio, L., and Jayakumar, P. (2009). Cellular Response to Biomaterials, Woodhead Publishing Limited.10.1533/9781845695477 ↗
45. The effects of combined micron-/submicron-scale surface roughness and nanoscale features on cell proliferation and differentiation10.1016/j.biomaterials.2011.01.029 ↗
46. Experiments on cell and axon orientation in vitro: The role of colloidal exudates in tissue organization
47. Regulation of Mesenchymal Stem Cell Differentiation by Nanopatterning of Bulk Metallic Glass10.1038/s41598-018-27098-6 ↗
48. Effects of artificial micro- and nano-structured surfaces on cell behaviour10.1016/j.aanat.2008.05.006 ↗
49. Cunha, A. (2015). Multiscale Femtosecond Laser Surface Texturing of Titanium and Titanium Alloys for Dental and Orthopaedic Implants, Universite de Bordeaux.10.1016/B978-0-08-100883-6.00011-3 ↗
50. The cultivation of tissues in extraneous media as a method of morpho-genetic study10.1002/ar.1090060404 ↗
51. Topographical control of cells10.1016/S0142-9612(97)00144-0 ↗
52. Geometric cues for directing the differentiation of mesenchymal stem cells10.1073/pnas.0903269107 ↗
53. Jimenez-Vergara, A.C. (2019). Refined assessment of the impact of cell shape on human mesenchymal stem cell differentiation in 3D contexts. Acta Biomater.10.1016/j.actbio.2019.01.052 ↗
54. Early Human Bone Response to Laser Metal Sintering Surface Topography: A Histologic Report10.1563/AAID-JOI-D-09-00003 ↗
55. Effect of different titanium laser surface treatments on osseointegration
56. Osteogenic potential of laser modified and conditioned titanium zirconium surfaces10.4103/0972-4052.186403 ↗
57. Enhanced biocompatible and hemocompatible nano/micro porous surface as a biological scaffold for functionalizational and biointegrated implants10.1016/j.jallcom.2016.05.134 ↗
58. The relationship between the nanostructure of titanium surfaces and bacterial attachment10.1016/j.biomaterials.2009.09.081 ↗
59. Effect of laser treatment on the attachment and viability of mesenchymal stem cell responses on shape memory NiTi alloy10.1016/j.msec.2014.05.022 ↗
60. Bacterial attachment and biofilm formation on surfaces are reduced by small-diameter nanoscale pores: How small is small enough?