journal article·2021-04-25Open access

Mechanical Properties, Corrosion Resistance and Bioactivity of Oxide Layers Formed by Isothermal Oxidation of Ti-6Al-7Nb Alloy

Krzysztof Aniołek, Bożena Łosiewicz, Julian Kubisztal, Patrycja Osak, Agnieszka Stróż, Adrian Barylski, Sławomir Kaptacz

Coatings· Volume 11· Issue 5

Abstract

Titanium and its alloys are among the most promising biomaterials for medical applications. In this work, the isothermal oxidation of Ti-6Al-7Nb biomedical alloy towards improving its mechanical properties, corrosion resistance, and bioactivity has been developed. The oxide layers were formed at 600, 700, and 800 °C for 72 h. Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), 3D profilometry, and microindentation test, were used to characterize microstructure, surface geometrical structure, and the hardness of the diphase (α + β) Ti-6Al-7Nb alloy after oxidation, respectively. In vitro corrosion resistance tests were carried out in a saline solution at 37 °C using the open-circuit potential method and potentiodynamic measurements. Electronic properties in the air were studied using the Scanning Kelvin Probe (SKP) technique. The bioactivity test was conducted by soaking the alkali- and heat-treated samples in simulated body fluid for 7 days. The presence of apatite was confirmed using SEM/EDS and Fourier Transform Infrared Spectroscopy (FTIR) studies. The thickness of oxide layers formed increased with the temperature growth from 0.25 to 5.48 µm. It was found that with increasing isothermal oxidation temperature, the surface roughness, hardness, corrosion resistance, and contact potential difference increased. The Ti-6Al-7Nb alloy after oxidation revealed the HAp-forming ability in a biological environment.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Materials Engineering, Faculty of Science and Technology, University of Silesia in Katowice, 75 Pułku Piechoty 1A, 41-500 Chorzów, Poland

References (71)

Show source-provided references
1. Titanium alloys for dental implants: A review10.3390/prosthesis2020011 ↗
2. 1.2 Electrochemical Behavior of Metals in the Biological Milieu
3. Verma, R.P. (2020). Titanium based biomaterial for bone implants: A mini review. Mater. Today Proc.10.1016/j.matpr.2020.02.649 ↗
4. Kapoor, N., Nagpal, A., and Verma, R. (2020). Surface Treatment of Titanium Implant and Dental Implant Design: Titanium as Biomaterial and Method Used for Surface Treatment to Increase Bone and Soft Tissue Integration, LAP LAMBERT Academic Publishing.10.18231/j.aprd.2020.041 ↗
5. Heat-treatment effects on mechanical properties and microstructure evolution of Ti-6Al-4V alloy fabricated by laser powder bed fusion10.1016/j.jallcom.2019.152615 ↗
6. Thermal oxidation of Ti6Al4V alloy and its biotribological properties under serum lubrication10.1016/j.triboint.2014.12.022 ↗
7. Thick rutile layer on titanium for tribological applications10.1016/j.triboint.2005.08.004 ↗
8. Surface engineering of titanium-based implants using electrospraying and dip coating methods10.1016/j.msec.2019.01.027 ↗
9. Bone-like apatite formation on manganese-hydroxyapatite coating formed on Ti-6Al-4V alloy by plasma electrolytic oxidation10.1016/j.tsf.2016.07.088 ↗
10. Characterization of thermally oxidized Ti6Al7Nb alloy for biological applications10.1007/s12540-011-1011-5 ↗
11. Effect of thermal oxidation on corrosion and corrosion–wear behaviour of a Ti-6Al-4V alloy10.1016/j.biomaterials.2003.10.009 ↗
12. Improvement of the biomedical properties of titanium using SMAT and thermal oxidation10.1016/j.colsurfb.2013.10.039 ↗
13. Influence of niobium or molybdenum in titanium alloy for permanent implant application10.4028/www.scientific.net/AMR.900.53 ↗
14. Improving hot corrosion resistance of two phases intermetallic alloy α2-Ti3Al/γ-TiAl with enamel coating10.1063/1.4974444 ↗
15. Deformation in fatigue crack tip plastic zone and its role in crack propagation of titanium alloy with tri-modal microstructure10.1016/j.msea.2018.10.049 ↗
16. Microstructure and shear fracture characteristics of porous anodic TiO2 layer before and after hot water treatment10.1016/j.apsusc.2011.03.101 ↗
17. Fabrication and synthesis of uniform TiO2 nanoporous and nanotubular structures on dual-phase Ti-6Al-4V alloy using electron-beam irradiation10.1016/j.matchemphys.2019.122549 ↗
18. Effects of pore size and porosity of surface-modified porous titanium implants on bone tissue ingrowth10.1016/S1003-6326(19)65161-7 ↗
19. Tallarico, M., Ceruso, F.M., Muzzi, L., Meloni, S.M., Kim, Y.J., Gargari, M., and Martinolli, M. (2019). Effect of simultaneous immediate implant placement and guided bone reconstruction with ultra-fine titanium mesh membranes on radiographic and clinical parameters after 18 months of loading. Materials, 12.10.3390/ma12101710 ↗
20. Oral piercing and oral diseases: A short time retrospective study10.7150/ijms.8.649 ↗
21. Siwakul, P., Sirinnaphakorn, L., Suwanprateep, J., Hayakawa, T., and Pugdee, K. (2021). Cellular responses of histatin-derived peptides immobilized titanium surface using a tresyl chloride-activated method. Dent. Mater. J.10.4012/dmj.2020-307 ↗
22. Reduced toxicity and superior cellular response of preosteoblasts to Ti-6Al-7Nb alloy and comparison with Ti-6Al-4V10.1002/jbm.a.34492 ↗
23. Effect of acid treatment on the surface modification of Ti-6Al-7Nb and Ti-5Al-2Nb-1Ta and its electrochemical investigations in simulated body fluid10.1007/s40735-017-0096-x ↗
24. In vitro and in vivo studies of alkali- and heat-treated Ti-6Al-7Nb and Ti-5Al-2Nb-1Ta alloys for orthopedic implants10.1002/jbm.a.32099 ↗
25. Hu, N., Xie, L., Liao, Q., Gao, A., Zheng, Y., Pan, H., Tong, L., Yang, D., Gao, N., and Starink, M.J. (2021). A more defective substrate leads to a less defective passive layer: Enhancing the mechanical strength, corrosion resistance and anti-inflammatory response of the low-modulus Ti-45Nb alloy by grain refinement. Acta Biomater.10.1016/j.actbio.2021.02.045 ↗
26. Mechanical, tribological and adhesive properties of oxide layers obtained on the surface of the Ti–6Al–7Nb alloy in the thermal oxidation process
27. Thermal oxidation of Ti-6Al–4V alloy and pure titanium under external bending strain: Experiment and modelling10.1016/j.corsci.2017.01.009 ↗
28. Study of Ti–6Al–4V alloy spectral emissivity characteristics during thermal oxidation process10.1016/j.ijheatmasstransfer.2016.05.069 ↗
29. Thermal oxidation of titanium to improve corrosion resistance in boiling nitric acid medium10.1016/j.surfcoat.2013.07.010 ↗
30. The influence of thermal oxidation parameters on the growth of oxide layers on titanium10.1016/j.vacuum.2017.07.023 ↗
31. Cao, L., Wan, Y., Yang, S., and Pu, J. (2018). The tribocorrosion and corrosion properties of thermally oxidized Ti6Al4V alloy in 0.9 wt.% NaCl physiological saline. Coatings, 8.10.3390/coatings8080285 ↗
32. Structure and properties of titanium and the Ti-6Al-7Nb alloy after isothermal oxidation10.1080/02670844.2020.1711631 ↗
33. The influence of thermal oxidation parameters on structural, friction, and wear characteristics of oxide layers produced on the surface of Ti-6Al-7Nb alloy
34. Review on wear and corrosion behavior of thermal oxidation on titanium-based alloy for biomedical application
35. Thermal oxidation of Ti6Al4V alloy: Microstructural and electrochemical characterization10.1016/j.matchemphys.2009.09.007 ↗
36. Improving the wear resistance of Ti-6Al-4V/TiC composites through thermal oxidation (TO)10.1016/j.wear.2010.06.006 ↗
37. Influence of thermal oxidation temperature on the microstructural and tribological behavior of Ti6Al4V alloy10.1016/j.surfcoat.2014.01.004 ↗
38. Tribological behavior of Ti-6Al-4V and Ti-6Al-7Nb alloys for total hip prosthesis10.1155/2014/451387 ↗
39. Isothermal oxidation of Ti-6Al-7Nb alloy10.1016/j.vacuum.2015.01.016 ↗
40. ISO 14577-4 (2016). Metallic Materials—Instrumented Indentation Test for Hardness and Materials Parameters—Part 4: Test Method for Metallic and Non-Metallic Coatings, ISO.
41. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments10.1557/JMR.1992.1564 ↗
42. ISO 10271 (2011). Dentistry—Corrosion Test Methods for Metallic Materials, ISO.
43. Application of EIS to study the corrosion resistance of passivated NiTi shape memory alloy in simulated body fluid10.4028/www.scientific.net/SSP.183.57 ↗
44. Production, structure and biocompatible properties of oxide nanotubes on Ti13Nb13Zr alloy for medical applications10.1016/j.matchar.2017.09.004 ↗
45. Eco Chemie, B.V. (1998). Electrochemical Instruments, Description of the Instrument, Kanaalweg.
46. Nanostructured positively charged bioactive TiO2 layer formed on Ti metal by NaOH, acid and heat treatments10.1007/s10856-011-4372-x ↗
47. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
48. Thermal oxidation of CP Ti—An electrochemical and structural characterization10.1016/j.matchar.2010.03.002 ↗
49. Corrosion behaviour of polished and sandblasted titanium alloys in PBS solution
50. ISO 5832-11 (2014). Implants for Surgery—Metallic Materials—Part 11: Wrought Titanium 6-Aluminium 7-Niobium Alloy, ISO.
51. Influence of thermal oxidation duration on the microstructure and fretting wear behavior of Ti6Al4V alloy10.1016/j.matchemphys.2015.03.063 ↗
52. Effect of thermal oxidation on corrosion resistance of commercially pure titanium in acid medium10.1007/s11665-011-9970-8 ↗
53. Bard, A.J., and Faulkner, L.R. (2001). Electrochemical Methods. Fundamentals and Applications, John Wiley & Sons Inc.. [2nd ed.].
54. ASTM G102—89(2015)e1 (2015). Standard Practice for Calculation of Corrosion Rates and Related Information from Electrochemical Measurements, National Association of Corrosion Engineers.
55. Pourbaix, M. (1974). Atlas of Electrochemical Equilibria in Aqueous Solutions, NACE International, National Association of Corrosion Engineers. [2nd English ed.].
56. Electrochemical investigations of Ti6Al4V and Ti6Al7Nb alloys used on implants in bone surgery
57. Mechanical properties and corrosion resistance of Ti±6Al±7Nb alloy dental castings10.1023/A:1008909408948 ↗
58. Corrosion and passivity of Ti-13% Nb-13% Zr in comparison to other biomedical implant alloys10.5006/1.3290281 ↗
59. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution10.1016/S0142-9612(03)00252-7 ↗
60. Effect of polarization scan rate on the pitting potential of the self-passivated NiTi shape memory alloy in a simulated body fluid10.4028/www.scientific.net/SSP.227.443 ↗
61. EIS study on interfacial properties of passivated Nitinol orthodontic wire in saliva modified with Eludril® mouthwash10.1134/S2070205118040226 ↗
62. Corrosion resistance of Ti and Ti-Pd alloy in phosphate buffered saline solutions with and without H2O2 addition10.1016/S1003-6326(13)62541-8 ↗
63. Kubisztal, J., Losiewicz, B., Dybal, P., Kozik, V., and Bak, A. (2020). Temperature-related corrosion resistance of AISI 1010 carbon steel in sulfolane. Materials, 13.10.3390/ma13112563 ↗
64. Bak, A., Losiewicz, B., Kozik, V., Kubisztal, J., Dybal, P., Swietlicka, A., Barbusinski, K., Kus, S., Howaniec, N., and Jampilek, J. (2019). Real-time corrosion monitoring of AISI 1010 carbon steel with metal surface mapping in sulfolane. Materials, 12.10.3390/ma12193276 ↗
65. Surfactant assisted synthesis and characterization of hydroxyapatite nanorods under hydrothermal condition
66. Enhancing surface characteristics of Ti–6Al–4V for bio-implants using integrated anodization and thermal oxidation10.1039/c3tb21731k ↗
67. Bone and Tooth Mineralization: Why Apatite?10.2113/GSELEMENTS.4.2.97 ↗
68. Combes, C., Cazalbou, S., and Rey, C. (2016). Apatite Biominerals. Minerals, 6.10.3390/min6020034 ↗
69. In Vitro Studies of α-TCP and β-TCP Produced from Clinocardium Ciliatum Seashells10.1007/s41779-019-00355-1 ↗
70. Ceruso, F.M., Ieria, I., Martelli, M., Lumbau, A.I., Xhanari, E., and Gargari, M. (2021). New generation of fixture–abutment connection combining soft tissue design and vertical screw-retained restoration: 1-Year clinical, aesthetics and radiographic preliminary evaluation. Dent. J., 9.10.3390/dj9040035 ↗
71. Dental pulp stem cell mechanoresponsiveness: Effects of mechanical stimuli on dental pulp stem cell behavior10.3389/fphys.2018.01685 ↗