journal article·2019-09-25Open access

Bioactive Coating on Titanium Dental Implants for Improved Anticorrosion Protection: A Combined Experimental and Theoretical Study

Jozefina Katić, Ankica Šarić, Ines Despotović, Nives Matijaković, Marin Petković, Željka Petrović

Coatings· Volume 9· Issue 10

Abstract

In recent years, extensive studies have been continuously undertaken on the design of bioactive and biomimetic dental implant surfaces due to the need for improvement of the implant–bone interface properties. In this paper, the titanium dental implant surface was modified by bioactive vitamin D3 molecules by a self-assembly process in order to form an improved anticorrosion coating. Surface characterization of the modified implant was performed by field emission scanning electron microscopy (FE-SEM), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), and contact angle measurements (CA). The implant’s electrochemical stability during exposure to an artificial saliva solution was monitored in situ by electrochemical impedance spectroscopy (EIS). The experimental results obtained were corroborated by means of quantum chemical calculations at the density functional theory level (DFT). The formation mechanism of the coating onto the titanium implant surface was proposed. During a prolonged immersion period, the bioactive coating effectively prevented a corrosive attack on the underlying titanium (polarization resistance in order of 107 Ω cm2) with ~95% protection effectiveness.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Bone Tissue Engineering Materials · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrochemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev trg 19, 10000 Zagreb, Croatia

Division of Materials Physics, Centre of Excellence for Advanced Materials and Sensing Device, Ruđer Bošković Institute, Bijenička cesta 54, 10002 Zagreb, Croatia

Division of Physical Chemistry, Ruđer Bošković Institute, Bijenička cesta 54, 10002 Zagreb, Croatia

Division of Materials Chemistry, Ruđer Bošković Institute, Bijenička cesta 54, 10002 Zagreb, Croatia

Adentro dental studio, Petrova ul. 67, 10000 Zagreb, Croatia

References (53)

Show source-provided references
1. Eliaz, N. (2019). Corrosion of Metallic Biomaterials: A Review. Materials, 12.10.3390/ma12030407 ↗
2. Metal Corrosion in the Human Body: The Ultimate Bio-Corrosion Scenario10.1149/2.F04082IF ↗
3. Current trends in dental implants10.5125/jkaoms.2014.40.2.50 ↗
4. Metal allergy patient treated by titanium implant denture: A case report with at least 4-year follow-up10.1002/ccr3.1753 ↗
5. Titanium allergy: Could it affect dental implant integration?10.1111/j.1600-0501.2010.02081.x ↗
6. Syed, M., Chopra, R., and Sachdev, V. (2015). Allergic Reactions to Dental Materials—A Systematic Review. J. Clin. Diagn. Res., 9.10.7860/JCDR/2015/15640.6589 ↗
7. Titanium allergy in dental implant patients: A clinical study on 1500 consecutive patients10.1111/j.1600-0501.2008.01544.x ↗
8. Smeets, R., Stadlinger, B., Schwarz, F., Beck-Broichsitter, B., Jung, O., Precht, C., Kloss, F., Gröbe, A., Heiland, M., and Ebker, T. (2016). Impact of Dental Implant Surface Modifications on Osseointegration. BioMed Res. Int., 2016.10.1155/2016/6285620 ↗
9. Dental Implant Bioactive Surface Modifiers: An Update10.4103/jispcd.JISPCD_303_18 ↗
10. Corrosion behavior of TiN and TiN/Ti composite films on Ti6Al4V alloy in Hanks solution10.1007/s10800-008-9690-4 ↗
11. Osteoinduction by calcium phosphate biomaterials10.1023/A:1008950902047 ↗
12. Titanium Coating with Hydroxyapatite and Chitosan Doped with Silver Nitrate10.1590/1980-5373-mr-2017-0021 ↗
13. Hydroxyapatite coating on titanium endosseous implants for improved osseointegration: Physical and chemical considerations10.17219/acem/69084 ↗
14. Current perspectives: Calcium phosphates nanocoatings and nanocomposite coatings in dentistry10.1177/0022034513497754 ↗
15. Rojo, L., Gharibi, B., McLister, R., Meenan, B.J., and Deb, S. (2016). Self-assembled monolayers of alendronate on Ti6Al4V alloy surfaces enhance osteogenesis in mesenchymal stem cells. Sci. Rep., 6.10.1038/srep30548 ↗
16. An In Vitro Assessment of Fibroblast and Osteoblast Response to Alendronate-Modified Titanium and the Potential for Decreasing Fibrous Encapsulation10.1089/ten.tea.2012.0218 ↗
17. The effect of vitamin D3 on the osteointegration of dental implant10.29359/BJHPA.10.4.02 ↗
18. Titanium implants coated with UV-irradiated vitamin D precursor and vitamin E: In vivo performance and coating stability
19. (2018). ISO 5832-2:2018 Implants for surgery - Metallic materials—Part 2: Unalloyed titanium, ISO.
20. (2019, June 25). Available online: https://www.upmet.com/products/titanium/cp-grade-2.
21. Monolayer vs. multilayer self-assembled alkylphosphonate films: X-ray photoelectron spectroscopy studies10.1016/j.susc.2005.11.030 ↗
22. Modification of a Nitinol Surface by Phosphonate Self-Assembled Monolayers10.1149/1.3617651 ↗
23. Mellado-Valero, A., Muñoz, A.I., Pina, V.G., and Sola-Ruiz, M.F. (2018). Electrochemical Behaviour and Galvanic Effects of Titanium Implants Coupled to Metallic Suprastructures in Artificial Saliva. Materials, 11.10.3390/ma11010171 ↗
24. A Nonlinear Least Squares Fit procedure for analysis of immittance data of electrochemical systems10.1016/0167-2738(86)90031-7 ↗
25. Frisch, M.J., Trucks, G.W., Schlegel, H.B., Scuseria, G.E., Robb, M.A., Cheeseman, J.R., Scalmani, G., Barone, V., Mennucci, B., and Petersson, G.A. (2013). Gaussian 09, Revision D.01, Gaussian, Inc.
26. Role of TiO2 Anatase Surface Morphology on Organophosphorus Interfacial Chemistry10.1021/acs.jpcc.8b08641 ↗
27. Theoretical Study of Stable, Defect-Free (TiO2)n Nanoparticles with n = 10–1610.1021/jp073988t ↗
28. The M06 suite of density functionals for main group thermochemistry, thermochemical kinetics, noncovalent interactions, excited states, and transition elements: Two new functionals and systematic testing of four M06-class functionals and 12 other functionals10.1007/s00214-007-0310-x ↗
29. Density Functionals with Broad Applicability in Chemistry10.1021/ar700111a ↗
30. Density Functional Theory for Reaction Energies: Test of Meta and Hybrid Meta Functionals, Range-Separated Functionals, and Other High-Performance Functionals10.1021/ct1006604 ↗
31. Ab initio effective core potentials for molecular calculations. Potentials for main group elements Na to Bi10.1063/1.448800 ↗
32. Universal Solvation Model Based on Solute Electron Density and on a Continuum Model of the Solvent Defined by the Bulk Dielectric Constant and Atomic Surface Tensions10.1021/jp810292n ↗
33. Keith, T.A. (2019, February 12). AIMAll (Version 17.01.25). Available online: http://aim.tkgristmill.com/versionhistory.html.
34. Bader, R.F.W. (1994). Atoms in Molecules: A Quantum Theory, Oxford University Press.
35. Roughness induced dynamic changes of wettability of acid etched titanium implant modifications10.1016/j.biomaterials.2003.08.015 ↗
36. Increased osteoblast adhesion on nanophase metals: Ti, Ti6Al4V, and CoCrMo10.1016/j.biomaterials.2003.12.002 ↗
37. Improvement of Titanium Corrosion Resistance by Coating with Poly-Caprolactone and Poly-Caprolactone/Titanium Dioxide: Potential Application in Heart Valves10.1590/1980-5373-mr-2017-0425 ↗
38. Synthesis and characterization of polyamide/polyester thin-film nanocomposite membranes achieved by functionalized TiO2 nanoparticles for water vapor separation10.1039/C6TA00100A ↗
39. Characterization of vitamin–cisplatin-loaded chitosan nano-particles for chemoprevention and cancer fatigue10.3109/02652048.2015.1065921 ↗
40. Orazem, M.E., and Tribollet, B. (2008). Electrochemical Impedance Spectroscopy, Wiley.10.1002/9780470381588 ↗
41. The analysis of electrode impedances complicated by the presence of a constant phase element10.1016/S0022-0728(84)80324-1 ↗
42. CPE analysis by local electrochemical impedance spectroscopy10.1016/j.electacta.2005.02.128 ↗
43. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application10.1016/0013-4686(95)00465-3 ↗
44. Kosec, T., Legat, A., Kovač, J., and Klobčar, D. (2019). Influence of Laser Colour Marking on the Corrosion Properties of Low Alloyed Ti. Coatings, 9.10.3390/coatings9060375 ↗
45. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials10.1016/S0142-9612(00)00309-4 ↗
46. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
47. Corrosion Behavior of Titanium in Artificial Saliva by Lactic Acid10.3390/ma7085528 ↗
48. Corrosion and Electrochemical Impedance Properties of Ti Alloys as Orthopaedic Trauma Implant Materials10.20964/2017.10.05 ↗
49. Nanostructured titanium-based materials for medical implants: Modeling and development10.1016/j.mser.2014.04.002 ↗
50. Polarization Resistance Method for Determination of Instantaneous Corrosion Rates10.5006/1.3280536 ↗
51. Electrochemical impedance spectroscopic studies of titanium and its alloys in saline medium10.1002/maco.200603979 ↗
52. Self-assembled monolayers of alkanethiols containing a polar aromatic group: Effects of the dipole position on molecular packing, orientation, and surface wetting properties10.1021/ja00011a010 ↗
53. Insulating Properties of Self-Assembled Monolayers Monitored by Impedance Spectroscopy10.1021/la991328c ↗