Progress in Wear Resistant Materials for Total Hip Arthroplasty
Source abstract
Abstract
Current trends in total hip arthroplasty (THA) are to develop novel artificial hip joints with high wear resistance and mechanical reliability with a potential to last for at least 25–30 years for both young and old active patients. Currently used artificial hip joints are mainly composed of femoral head of monolithic alumina or alumina-zirconia composites articulating against cross-linked polyethylene liner of acetabular cup or Co-Cr alloy in a self-mated configuration. However, the possibility of fracture of ceramics or its composites, PE wear debris-induced osteolysis, and hypersensitivity issue due to metal ion release cannot be eliminated. In some cases, thin ultra-hard diamond-based, TiN coatings on Ti-6A-4V or thin zirconia layer on the Zr-Nb alloy have been fabricated to develop high wear resistant bearing surfaces. However, these coatings showed poor adhesion in tribological testing. To provide high wear resistance and mechanical reliability to femoral head, a new kind of ceramic/metal artificial hip joint hybrid was recently proposed in which 10–15 μm thick dense layer of pure α-alumina was formed onto Ti-6Al-4V alloy by deposition of Al metal layer by cold spraying or cold metal transfer methods with 1–2 μm thick Al3Ti reaction layer formed at their interface to improve adhesion. An optimal micro-arc oxidation treatment transformed Al to dense α-alumina layer, which showed high Vickers hardness 1900 HV and good adhesion to the substrate. Further tribological and cytotoxicity analyses of these hybrids will determine their efficacy for potential use in THA.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Tribology and Wear Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249, USA
Department of Biomedical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249, USA
Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA 02114, USA
Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA 02115, USA
Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Raleigh, NC 27695, USA
References (100+)
Show source-provided references
1. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 203010.2106/00004623-200704000-00012 ↗
2. Renkawitz, T., Santori, F.S., Grifka, J., Valverde, C., Morlock, M.M., and Learmonth, I.D. (2008). A new short uncemented, proximally fixed anatomic femoral implant with a prominent lateral flare: Design rationals and study design of an international clinical trial. BMC Musculoskelet. Disord., 9.10.1186/1471-2474-9-147 ↗
3. Steens, W., Boettner, F., Bader, R., Skripitz, R., and Schneeberger, A. (2015). Bone mineral density after implantation of a femoral neck hip prosthesis-a prospective 5 year follow-up. BMC Musculoskelet. Disord., 16.10.1186/s12891-015-0624-0 ↗
4. The bone tissue compatibility of a new Ti-Nb-Sn alloy with a low Young’s modulus10.1016/j.actbio.2011.02.008 ↗
5. A novel metastable Ti-25Nb-2Mo-4Sn alloy with high strength and low Young’s modulus10.1007/s11661-012-1324-0 ↗
6. Development of low rigidity beta-type titanium alloy for biomedical applications10.2320/matertrans.43.2970 ↗
7. A new Ti-15Zr-4Nb-4Ta alloy for medical applications10.1016/S1359-0286(00)00025-5 ↗
8. Deposition and investigation of functionally graded calcium phosphate coatings on titanium10.1016/j.actbio.2009.05.013 ↗
9. Antibacterial effect and cytotoxicity of Ag-doped functionally graded hydroxyapatite coatings10.1002/jbm.b.31985 ↗
10. In vitro anti-bacterial and biological properties of magnetron co-sputtered silver-containing hydroxyapatite coating10.1016/j.biomaterials.2006.07.003 ↗
11. Structure solubility and bond strength of thin calcium-phosphate coatings produced by ion-beam sputter deposition10.1016/0142-9612(92)90192-Q ↗
12. Review on calcium phosphate coatings produced using a sputtering process—an alternative to plasma spraying10.1016/j.biomaterials.2004.02.029 ↗
13. Preparation of bioactive Ti and its alloys via simple chemical surface treatment10.1002/(SICI)1097-4636(199611)32:3<409::AID-JBM14>3.0.CO;2-B ↗
14. Graded surface structure of bioactive titanium prepared by chemical treatment10.1002/(SICI)1097-4636(199905)45:2<100::AID-JBM4>3.0.CO;2-0 ↗
15. Formation of bioactive functionally graded structure on Ti-6Al-4V alloy by chemical surface treatment10.1023/A:1008924102096 ↗
16. Preparation of bioactive Ti metal surface enriched with calcium ions by chemical treatment10.1016/j.actbio.2010.01.007 ↗
17. Positively charged bioactive Ti metal prepared by simple chemical and heat treatments10.1098/rsif.2010.0129.focus ↗
18. Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E10.1016/j.arth.2005.07.009 ↗
19. Vitamin E diffused, highly crosslinked UHMWPE: A review10.1007/s00264-010-1161-y ↗
20. Wear resistance of artificial hip joints with poly(2-methacryloyloxyethyl phosphorylcholine) grafted polyethylene: Comparisons with the effect of polyethylene cross-linking and ceramic femoral heads10.1016/j.biomaterials.2009.02.020 ↗
21. Superlubricious surface mimicking articular cartilage by grafting poly(2-methacryloyloxyethyl phosphorylcholine) on orthopaedic metal bearings10.1002/jbm.a.32280 ↗
22. Current status of zirconia used in total hip implants10.2106/00004623-200300004-00009 ↗
23. Investigations of the mechanical properties of an alumina toughened zirconia ceramic for an application in joint prostheses10.4028/www.scientific.net/KEM.284-286.1019 ↗
24. Wear of novel ceramic-on-ceramic bearings under adverse and clinically relevant hip simulator conditions10.1002/jbm.b.32965 ↗
25. Oxidation microstructures and interfaces in the oxidized zirconium knee10.1111/j.1744-7402.2005.02025.x ↗
26. Reduced wear with oxidized zirconium femoral heads10.2106/00004623-200300004-00013 ↗
27. High strength and toughness alumina matrix composites by transformation toughening and ‘in situ’ platelet reinforcement (ZPTA)—The new generation of bioceramics10.4028/www.scientific.net/KEM.192-195.545 ↗
28. Hip New World10.1115/1.2006-OCT-2 ↗
29. The optimum size of prosthetic heads in relation to wear of plastic sockets in total replacement of hip10.1007/BF02474667 ↗
30. Mechanism and clinical significance of wear debris-induced osteolysis10.1097/00003086-199203000-00003 ↗
31. Total arthroplasty of the hip by fritted alumina prosthesis. Experimental study and 1st clinical applications10.1016/j.otsr.2013.12.004 ↗
32. The prolem is osteolysis
33. Periacetabular osteolysis is the problem in contemporary total hip arthroplasty in young patients10.1016/j.arth.2011.03.022 ↗
34. Kurtz, S. (2009). Compendium of highly crosslinked UHMWPEs. UHMWPE Biomaterials Handbook, Elsevier.10.1016/B978-0-12-374721-1.00020-1 ↗
35. Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE10.1016/j.biomaterials.2005.06.025 ↗
36. Oxidation and other property changes of retrieved sequentially annealed UHMWPE acetabular and tibial bearings10.1002/jbm.b.33240 ↗
37. Effects of simulated oxidation on the in vitro wear and mechanical properties of irradiated and melted highly crosslinked UHMWPE10.1002/jbm.b.33368 ↗
38. Free radicals trapped in polyethylene crystals10.1080/00222349508215534 ↗
39. A study of long-lived free radicals in gamma-irradiated medical grade polyethylene10.1016/S0969-806X(01)00431-5 ↗
40. Properties of crosslinked ultra-high-molecular-weight polyethylene10.1016/S0142-9612(00)00195-2 ↗
41. The basis for a second-generation highly cross-linked UHMWPE10.1097/01.blo.0000238856.61862.7d ↗
42. In vivo oxidation in retrieved highly crosslinked tibial inserts10.1002/jbm.b.32805 ↗
43. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene10.1007/s11999-011-1872-4 ↗
44. Novel active stabilization technology in highly crosslinked UHMWPEs for superior stability10.1016/j.radphyschem.2014.05.017 ↗
45. Anti-oxidation treatment of ultra high molecular weight polyethylene components to decrease periprosthetic osteolysis: Evaluation of osteolytic and osteogenic properties of wear debris particles in a murine calvaria model10.1007/s11926-013-0325-3 ↗
46. Three year RSA evaluation of vitamin E diffused highly cross-linked polyethylene liners and cup stability10.1016/j.arth.2015.02.018 ↗
47. Highly lubricated polymer interfaces for advanced artificial hip joints through biomimetic design10.1038/pj.2015.45 ↗
48. The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA10.1007/s11999-012-2604-0 ↗
49. Serum and urine metal levels in patients with metal-on-metal surface arthroplasty10.1023/A:1021179029640 ↗
50. New insights into wear and biological effects of metal-on-metal bearings10.2106/JBJS.J.01877 ↗
51. Nickel, cobalt and chromium in consumer products: A role in allergic contact-dermatitis?10.1111/j.1600-0536.1993.tb03318.x ↗
52. Titanium as the material of choice for cementless femoral components in total hip arthroplasty
53. Effects of aluminum and other cations on the structure of brain and liver chromatin10.1021/bi00435a043 ↗
54. Effect of Ti, Al, and V ions on the relative growth rate of fibroblasts (L929) and osteoblasts (MC3T3-E1) cells10.3233/BME-1996-6202 ↗
55. High-cycle fatigue performance of solution-treated metastable-beta titanium alloys10.1016/S1359-6454(98)00343-7 ↗
56. Surface modification of a Ti-6Al-4V alloy by thermal oxidation10.1016/j.surfcoat.2004.05.018 ↗
57. Effect of thermal oxidation on corrosion and corrosion-wear behaviour of a Ti–6Al–4V alloy10.1016/j.biomaterials.2003.10.009 ↗
58. Laser surface modification of Ti–6Al–4V: Wear and corrosion characterization in simulated biofluid10.1177/0885328206055998 ↗
59. Surface modification of Ti-6Al-4V alloy via friction-stir processing: Microstructure evolution and dry sliding wear performance10.1016/j.surfcoat.2013.11.035 ↗
60. Needs of bioceramics to longevity of total joint arthroplasty10.4028/www.scientific.net/KEM.240-242.735 ↗
61. Evolution of alumina-on-alumina implants—A review10.1097/00003086-200010000-00008 ↗
62. Kokubo, T. (2008). Clinical applications of ceramic-ceramic combinations in joint replacement. Bioceramics and Their Clinical Applications, CRC.10.1533/9781845694227 ↗
63. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty10.2106/JBJS.F.00970 ↗
64. Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty10.1007/s00264-010-1187-1 ↗
65. How do alternative bearing surfaces influence wear behavior?10.5435/00124635-200800001-00018 ↗
66. Alumina-alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations10.1016/S0142-9612(02)00048-0 ↗
67. Alumina-on-alumina total hip prostheses in patients 40 years of age or younger10.1097/00003086-200010000-00010 ↗
68. Press-fit metal-backed alumina sockets: A minimum 5-year followup study10.1097/00003086-200010000-00016 ↗
69. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomised study10.1302/0301-620X.83B5.0830742 ↗
70. Wear of ultra-high-molecular-weight polyethylene cup articulating with 22.225 mm zirconia diameter head in cemented total hip arthroplasty10.1007/s00776-004-0777-4 ↗
71. Polyethylene wear rates with Zirconia and cobalt chrome heads in the ABG hip10.1177/112070000501500201 ↗
72. On the fracture of a zirconia ball head10.1007/s10856-006-7316-0 ↗
73. Advances in zirconia toughened alumina biomaterials for total joint replacement10.1016/j.jmbbm.2013.03.022 ↗
74. Green, D., Pezzotti, G., Sakakura, S., Ries, M., and Clarke, I. (2003, January 2–5). Zirconia ceramic femoral heads in the USA-retrieved zirconia heads-2 to 10 years out. Proceedings of the 49th Annual Meeting of the Orthopaedic Research Society, New Orleans, LA, USA.
75. Orthopedic applications of silicon nitride ceramics10.1016/j.actbio.2012.04.031 ↗
76. Ceramics and ceramic coatings in orthopaedics10.1016/j.jeurceramsoc.2015.07.034 ↗
77. Fracture toughness of ceramics and semi-brittle alloys using a miniaturized disk-bend test10.1007/PL00010875 ↗
78. Quantitative determination of the volume fraction of intergranular amorphous phase in sintered silicon nitride10.1016/j.msea.2003.05.004 ↗
79. Fabrication and evaluation of SixNy coatings for total joint replacements10.1007/s10856-012-4625-3 ↗
80. Structure and composition of silicon nitride and silicon carbon nitride coatings for joint replacements10.1016/j.surfcoat.2013.09.008 ↗
81. Fabrication and testing of silicon nitride bearings in total hip arthroplasty winner of the 2007 “HAP” PAUL Award10.1016/j.arth.2008.01.300 ↗
82. McEntire, B.J., Lakshminarayanan, R., Ray, D.A., Clarke, I.C., Puppulin, L., and Pezzotti, G. (2016). Silicon nitride bearings for total joint arthroplasty. Lubricants, 4.10.3390/lubricants4040035 ↗
83. Green, D., Donaldson, T., Williams, P., Pezzotti, G., and Clarke, I. (2007, January 11–14). Long term strip wear rates of 3rd and 4th generation ceramic-on-ceramic under microseparation. Proceedings of the 53rd Annual Meeting of the Orthopaedic Research Society, San Diego, CA, USA.
84. Kokubo, T. (2008). The design of ceramics for joint replacement. Bioceramics and Their Clinical Applications, Woodhead.
85. ATZ—A new material with a high potential in joint replacement10.4028/www.scientific.net/KEM.284-286.983 ↗
86. Prevalence of total hip and knee replacement in the United States10.2106/JBJS.N.01141 ↗
87. Aseptic loosening of total joint replacements: Mechanisms underlying osteolysis and potential therapies10.1186/ar2170 ↗
88. Nanostructured diamondlike carbon thin films for medical applications10.1016/j.msec.2005.01.026 ↗
89. Titanium nitride ceramic film against polyethylene: A 48-million cycle wear test
90. Retrospective lifetime estimation of failed and explanted diamond-like carbon coated hip joint balls10.1016/j.actbio.2012.04.016 ↗
91. Improved wear resistance of functional diamond like carbon coated Ti-6Al-4V alloys in an edge loading conditions10.1016/j.jmbbm.2016.04.004 ↗
92. Effect of nitrogen addition on the microstructure and mechanical properties of diamond films grown using high-methane concentrations10.1063/1.370787 ↗
93. Improved adhesion of ultra-hard carbon films on cobalt-chromium orthopaedic implant alloy10.1007/s10856-010-4207-1 ↗
94. Mechanical wear behavior of nanocrystalline and multilayer diamond coatings on temporomandibular joint implants10.1023/B:JMSM.0000032817.05997.d2 ↗
95. Tribological characterization of NCD in physiological fluids10.1016/j.diamond.2007.12.070 ↗
96. Residual stress minimum in nanocrystalline diamond films10.1063/1.2339042 ↗
97. Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions10.2106/00004623-200200002-00018 ↗
98. Surface damage to an Oxinium femoral head prosthesis after dislocation10.1302/0301-620X.89B4.17557 ↗
99. Surface oxidized zirconium total hip arthroplasty head damage due to closed reduction10.1016/j.arth.2008.07.009 ↗
100. Formation of alumina layer on Ti alloy for artificial hip joint10.4028/www.scientific.net/KEM.614.200 ↗