Coating Thickness Determination Using X-ray Fluorescence Spectroscopy: Monte Carlo Simulations as an Alternative to the Use of Standards
Source abstract
Abstract
X-ray fluorescence is often employed in the measurement of the thickness of coatings. Despite its widespread nature, the task is not straightforward because of the complex physics involved, which results in high dependence on matrix effects. Thickness quantification is accomplished using the Fundamental Parameters approach, adjusted with empirical measurements of standards with known composition and thickness. This approach has two major drawbacks: (i) there are no standards for any possible coating and coating architecture and (ii) even relying on standards, the quantification of unknown samples requires the precise knowledge of the matrix nature (e.g., in the case of multilayer coatings the thickness and composition of each underlayer). In this work, we describe a semiquantitative approach to coating thickness measurement based on the construction of calibration curves through simulated XRF spectra built with Monte Carlo simulations. Simulations have been performed with the freeware software XMI-MSIM. We have assessed the accuracy of the methods by comparing the results with those obtained by (i) XRF thickness determination with standards and (ii) FIB-SEM cross-sectioning. Then we evaluated which parameters are critical in this kind of indirect thickness measurement.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: X-ray Spectroscopy and Fluorescence Analysis · X-ray Diffraction in Crystallography · Cultural Heritage Materials Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Dipartimento di Chimica, Università degli Studi di Firenze, via della Lastruccia 3, 50019 Sesto Fiorentino (FI), Italy
Consiglio Nazionale delle Ricerche—Istituto di Chimica dei Composti OrganoMetallici (CNR-ICCOM), via Madonna del Piano 10, 50019 Sesto Fiorentino (FI), Italy
References (36)
Show source-provided references
1. Giurlani, W., Zangari, G., Gambinossi, F., Passaponti, M., Salvietti, E., Di Benedetto, F., Caporali, S., and Innocenti, M. (2018). Electroplating for decorative applications: recent trends in research and development. Coatings, 8.10.3390/coatings8080260 ↗
2. Quantitative thickness determination using X-ray fluorescence: Application to multiple layers10.1002/xrs.729 ↗
3. Determination of the thickness of coatings by means of a new XRF spectrometer10.1002/xrs.550 ↗
4. XRF Analysis of jewelry using fully standardless fundamental parameter approach
5. Quantitative X-ray fluorescence analysis of samples of less than “infinite thickness”: Difficulties and possibilities10.1016/j.sab.2009.09.005 ↗
6. Calculation methods for fluorescent X-ray spectrometry: Empirical coefficients vs. fundamental parameters10.1021/ac60263a023 ↗
7. Standardless X-ray fluorescence spectrometry (Fundamental parameter method using sensitivity library)
8. Basic fundamental parameters in X-ray fluorescence
9. Thickness and composition analysis of thin film samples using FP method by XRF analysis
10. Comparison of the quantitative results corrected by fundamental parameter method and difference calibration specimens in X-ray fluorescence spectrometry10.1016/j.jqsrt.2004.12.018 ↗
11. Comparison of standard-based and standardless methods of quantification used in X-ray fluorescence analysis: Application to the exoskeleton of clams10.1002/xrs.2819 ↗
12. Applicability of X-ray fluorescence spectroscopy as method to determine thickness and composition of stacks of metal thin films: A comparison with imaging and profilometry10.1016/j.tsf.2011.08.049 ↗
13. Accuracy of standardless FP analysis of bulk and thin film samples using a new atomic database
14. Reconsidering the accuracy of X-ray fluorescence and ion beam based methods when used to measure the thickness of ancient gildings10.1016/j.sab.2017.06.017 ↗
15. An energy-dispersive X-ray fluorescence spectrometry and Monte Carlo simulation study of Iron-Age Nuragic small bronzes (“Navicelle”) from Sardinia, Italy10.1016/j.sab.2016.07.011 ↗
16. Use of Monte Carlo simulation as a tool for the nondestructive energy dispersive X-ray fluorescence (ED-XRF) spectroscopy analysis of archaeological copper-based artifacts from the Chalcolithic site of Perdigões, Southern Portugal10.1177/0003702817721934 ↗
17. 2017 atomic spectrometry update—A review of advances in X-ray fluorescence spectrometry and its special applications10.1039/C7JA90035J ↗
18. Brunetti, A., Fabian, J., La Torre, C.W., and Schiavon, N. (2016). A combined XRF/Monte Carlo simulation study of multilayered Peruvian metal artifacts from the tomb of the Priestess of Chornancap. Appl. Phys. A Mater. Sci. Process., 122.10.1007/s00339-016-0096-6 ↗
19. Absolute mass thickness determination of thin samples by X-ray fluorescence analysis10.1016/S0168-583X(98)00412-1 ↗
20. Monte Carlo simulation of X-ray imaging and spectroscopy experiments using quadric geometry and variance reduction techniques10.1016/j.cpc.2013.10.034 ↗
21. A general Monte Carlo simulation of energy dispersive X-ray fluorescence spectrometers—Part 5: Polarized radiation, stratified samples, cascade effects, M-lines10.1016/j.sab.2012.03.011 ↗
22. A general Monte Carlo simulation of energy-dispersive X-ray fluorescence spectrometers—Part 6. Quantification through iterative simulations10.1016/j.sab.2012.12.011 ↗
23. The xraylib library for X-ray-matter interactions. Recent developments10.1016/j.sab.2011.09.011 ↗
24. A general Monte Carlo simulation of energy-dispersive X-ray fluorescence spectrometers—I: Unpolarized radiation, homogeneous samples10.1016/0584-8547(93)80060-8 ↗
25. A general Monte Carlo simulation of ED-XRF spectrometers. II: Polarized monochromatic radiation, homogeneous samples10.1016/0584-8547(94)00124-E ↗
26. A general Monte Carlo simulation of energy-dispersive X-ray fluorescence spectrometers. Part 3. Polarized polychromatic radiation, homogeneous samples10.1016/0584-8547(95)01361-X ↗
27. Monte Carlo simulation of X-ray fluorescence spectra: Part 4. Photon scattering at high X-ray energies10.1016/S0584-8547(99)00094-4 ↗
28. (2018, December 20). Pathfinder™ X-ray Microanalysis Software. Available online: https://www.thermofisher.com/order/catalog/product/IQLAADGABKFAQOMBJE.
29. Castaing, R. (1951). Application of Electron Probes to Local Chemical and Crystallographic Analysis. [Ph.D. Thesis, University of Paris].
30. Giurlani, W., Innocenti, M., and Lavacchi, A. (2018). X-ray microanalysis of precious metal thin films: Thickness and composition determination. Coatings, 8.10.3390/coatings8020084 ↗
31. Analytical functions for fitting K X-ray doublet peaks from Si(Li) detectors10.1016/0168-583X(86)90456-8 ↗
32. Analytic approximations to peak shapes produced by Ge(Li) and Si(Li) spectrometers10.1016/0029-554X(75)90304-3 ↗
33. ED-XRF spectrum evaluation and quantitative analysis using multivariate and nonlinear techniques
34. Curve-fitting regression: Improving light element quantification with XRF10.1002/xrs.2760 ↗
35. Oberg, E., Jones, F., Horton, H., Ryffel, H., and McCauley, C. (2016). Machinery’s Handbook, Industrial Press, Inc.. [30th ed.].
36. Simulation of relationships between substrate XRF intensities and film thicknesses10.1002/xrs.1300220104 ↗