Titanium Nitride and Nitrogen Ion Implanted Coated Dental Materials
Source abstract
Abstract
Titanium nitride and/or nitrogen ion implanted coated dental materials have been investigated since the mid-1980s and considered in various applications in dentistry such as implants, abutments, orthodontic wires, endodontic files, periodontal/oral hygiene instruments, and casting alloys for fixed restorations. Multiple methodologies have been employed to create the coatings, but detailed structural analysis of the coatings is generally lacking in the dental literature. Depending on application, the purpose of the coating is to provide increased surface hardness, abrasion/wear resistance, esthetics, and corrosion resistance, lower friction, as well as greater beneficial interaction with adjacent biological and material substrates. While many studies have reported on the achievement of these properties, a consensus is not always clear. Additionally, few studies have been conducted to assess the efficacy of the coatings in a clinical setting. Overall, titanium nitride and/or nitrogen ion implanted coated dental materials potentially offer advantages over uncoated counterparts, but more investigation is needed to document the structure of the coatings and their clinical effectiveness.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Dental Biomaterials Research and Development Chair, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
School of Dentistry, Marquette University, Milwaukee, WI 53233, USA
Dental Biomaterials, School of Dentistry, Marquette University, Milwaukee, WI 53233, USA
Department of Biomaterials, School of Dentistry, University of Athens, Athens, Greece
References (71)
Show source-provided references
1. Titanium nitride coatings in clinical dentistry10.1016/0300-5712(92)90021-4 ↗
2. Bacterial adhesion on titanium nitride-coated and uncoated implants: An in vivo human study10.1563/1548-1336(2003)029<0080:BAOTNA>2.3.CO;2 ↗
3. Titanium nitride oxide coating on rough titanium stimulates the proliferation of human primary osteoblasts10.1111/j.1600-0501.2010.02033.x ↗
4. Biological response of human bone marrow stromal cells to sandblasted titanium nitride-coated implant surfaces10.1007/s10856-008-3514-2 ↗
5. Bone healing around titanium and titanium nitride-coated dental implants with three surfaces: An experimental study in rats10.1111/j.1708-8208.2003.tb00191.x ↗
6. Production of low-friction and colored TMA by ion implantation
7. Pitting corrosion resistance of nickel-titanium rotary instruments with different surface treatments in seventeen percent ethylenediaminetetraacetic acid and sodium chloride solutions10.1016/j.joen.2007.11.012 ↗
8. Influence of surface modifications to titanium on antibacterial activity in vitro10.1016/S0142-9612(00)00392-6 ↗
9. Influence of surface modifications to titanium on oral bacterial adhesion in vitro10.1002/1097-4636(200011)52:2<388::AID-JBM20>3.0.CO;2-E ↗
10. Tissue response to implanted ceramic-coated titanium alloys in rats10.1111/j.1365-2842.1988.tb00166.x ↗
11. Comparison of friction force between corroded and noncorroded titanium nitride plating of metal brackets10.1016/j.ajodo.2009.06.034 ↗
12. The anticorrosion ability of titanium nitride (TiN) plating on an orthodontic metal bracket and its biocompatibility10.1002/jbm.10484 ↗
13. Corrosion resistance of a magnetic stainless steel ion-plated with titanium nitride10.1046/j.1365-2842.2000.00520.x ↗
14. Adhesive bonding of titanium nitride-plated stainless steel for magnetic attachments10.1034/j.1600-0722.2001.00023.x ↗
15. The treatment of uncoated and titanium nitride-coated abutments with different instruments
16. The effects of titanium nitride-coating on the topographic and biological features of TPS implant surfaces10.1016/j.jdent.2011.08.003 ↗
17. Effect of physical vapor deposition on cutting efficiency of nickel-titanium files10.1097/00004770-200212000-00002 ↗
18. Effect of sterilization on the cutting efficiency of PVD-coated nickel-titanium endodontic instruments10.1046/j.1365-2591.2002.00586.x ↗
19. A comparison of the marginal adaptation of cathode-arc vapor-deposited titanium and cast base metal copings10.1016/S0022-3913(11)60083-8 ↗
20. Characteristics and porcelain bond strength of (Ti,Al)N coating on dental alloys10.1002/jbm.10307 ↗
21. Kurt, M., Külünk, T., Ural, C., Külünk, S., Danişman, S., and Savaş, S. (2010). The effect of different surface treatments on retention of cement retained implant supported restorations. J. Oral Implant.
22. Plaque formation on surface modified dental implants: An in vitro study10.1034/j.1600-0501.2001.120601.x ↗
23. Do different implant surfaces exposed in the oral cavity of humans show different biofilm compositions and activities?10.1111/j.1600-0722.2004.00171.x ↗
24. Fibroblast growth on surface-modified dental implants: An in vitro study
25. Focal adhesion contact formation by fibroblasts cultured on surface-modified dental implants: An in vitro study10.1111/j.1600-0501.2006.01277.x ↗
26. Shear bond strength of veneering composite resin to titanium nitride coating alloy deposited by radiofrequency sputtering10.1016/j.jdent.2005.07.002 ↗
27. Effect of nitride film coatings on cell compatibility10.1016/j.dental.2007.11.020 ↗
28. Depositions of nitrogen on NiTi instruments10.1097/00004770-200207000-00001 ↗
29. Effects of titanium nitride coatings on surface and corrosion characteristics of Ni-Ti alloy10.4012/dmj.13.228 ↗
30. Titanium-porcelain system Part I: Oxidation kinetics of nitrided pure titanium, simulated to porcelain firing process
31. Fracture load of titanium crowns coated with gold or titanium nitride and bonded to low-fusing porcelain10.1016/S0022-3913(11)60023-1 ↗
32. Wear resistance of nickel-titanium endodontic files after surface treatment10.1007/s10856-008-3439-9 ↗
33. Corrosion behavior of ion implanted nickel-titanium orthodontic wire in fluoride mouth rinse solutions10.4012/dmj.2009-069 ↗
34. Application of plasma immersion ion implantation for surface modification of nickel-titanium rotary instruments10.4012/dmj.26.467 ↗
35. The effect of surface treatments of nickel-titanium files on wear and cutting efficiency10.1016/S1079-2104(00)70103-X ↗
36. Cyclic fatigue resistance of rotary nickel-titanium instruments submitted to nitrogen ion implantation10.1016/j.joen.2010.03.032 ↗
37. The effect of argon and nitrogen ion implantation on nickel-titanium rotary instruments10.1016/j.joen.2009.07.023 ↗
38. Mesenchymal stem cell adhesion and spreading on nanostructured biomaterials10.1166/jnn.2004.137 ↗
39. Ion implantation: Surface treatment for improving the bone integration of titanium and Ti6Al4V dental implants10.1034/j.1600-0501.2003.140108.x ↗
40. Frictional coefficients of ion-implanted alumina against ion-implanted beta-titanium in the low load, low velocity, single pass regime10.1016/0109-5641(92)90076-O ↗
41. Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: Effect of ion implantation10.1097/00004770-200109000-00009 ↗
42. Abrasion resistance of titanium nitride coatings formed on titanium by ion-beam-assisted deposition10.1111/j.1365-2842.2004.01382.x ↗
43. Surface properties and biocompatibility of nitrided titanium for abrasion resistant implant materials10.4012/dmj.21.355 ↗
44. Improvement of the friction behaviour of NiTi orthodontic archwires by nitrogen diffusion
45. Inhibition of Ni release from NiTi and NiTiCu orthodontic archwires by nitrogen diffusion treatment
46. Fabrication of hard coatings on NiTi instruments10.1097/00004770-200302000-00011 ↗
47. Clinical performance and material properties of single-implant overdenture attachment systems
48. Vertical distraction osteogenesis using a titanium nitride-coated distractor10.1016/j.tripleo.2009.01.007 ↗
49. Effect of simulated masticatory loading on the retention of stud attachments for implant overdentures10.1111/j.1365-2842.2010.02145.x ↗
50. Preload evaluation of different screws in external hexagon joint10.1097/ID.0b013e31823fcbce ↗
51. The effect of surface treatment and clinical use on friction in NiTi orthodontic wires10.1016/j.dental.2004.11.011 ↗
52. D’Antò, V., Rongo, R., Ametrano, G., Spagnuolo, G., Manzo, P., Martina, R., Paduano, S., and Valletta, R. (2012). Evaluation of surface roughness of orthodontic wires by means of atomic force microscopy. Angle Orthod.10.2319/100211-620.1 ↗
53. The frictional behavior of coated guiding archwires10.1007/s00056-002-0009-5 ↗
54. Comparisons of surface roughnesses and sliding resistances of 6 titanium-based or TMA-type archwires10.1016/j.ajodo.2003.09.034 ↗
55. A comparative study of the static and kinetic frictional resistance of titanium molybdenum alloy archwires in stainless steel brackets10.1093/ejo/26.1.105 ↗
56. Corrosion and permanent fracture resistance of coated and conventional orthodontic wires10.1023/A:1013831011241 ↗
57. The release of nickel from orthodontic NiTi wires is increased by dynamic mechanical loading but not constrained by surface nitridation10.1002/jbm.a.31097 ↗
58. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires
59. Allergies induced by orthodontic alloys: Incidence and impact on treatment-Results of a survey in private orthodontic offices in the Federal State of Hesse, Germany10.1007/s00056-004-0312-4 ↗
60. Influence of autoclave sterilization on the surface parameters and mechanical properties of six orthodontic wires10.1093/ejo/cjh076 ↗
61. The effects of ion implantation on rate of tooth movement: An in vitro model10.1016/S0889-5406(97)70275-0 ↗
62. Efficiency of multi-strand steel, superelastic Ni-Ti and ion-implanted Ni-Ti archwires for initial alignment10.1111/ocr.1998.1.1.12 ↗
63. Effect of ion implantation of TMA archwires on the rate of orthodontic sliding space closure10.1016/S0889-5406(98)70177-5 ↗
64. In vitro evaluation of three curettes with edge retention technology after extended use
65. Ultramorphology of the root surface subsequent to hand-ultrasonic simultaneous instrumentation during non-surgical periodontal treatments: An in vitro study10.1590/S1678-77572011000100015 ↗
66. Properties of a titanium nitride coating for dental instruments10.1016/0300-5712(91)90123-G ↗
67. The durability of ceramic coated dental instruments
68. Novel diamond-coated tools for dental drilling applications10.1080/03091900500217489 ↗
69. An evaluation of 55 cobalt substituted Nitinol wire for use in orthodontics10.14219/jada.archive.1971.0209 ↗
70. An evaluation of beta titanium alloys for use in orthodontic appliances10.1177/00220345790580020901 ↗
71. An initial investigation of the bending and torsional properties of Nitinol root canal files10.1016/S0099-2399(88)80196-1 ↗