journal article·2022-03-01Open access

Electrochemical Corrosion of Titanium and Titanium Alloys Anodized in H2SO4 and H3PO4 Solutions

Jesús Jáquez-Muñoz, Citlalli Gaona-Tiburcio, José Chacón-Nava, Jose Cabral-Miramontes, Demetrio Nieves-Mendoza, Erick Maldonado-Bandala, Anabel Delgado, Juan Flores-De los Rios, Patrizia Bocchetta, Facundo Almeraya-Calderón

Coatings· Volume 12· Issue 3

Abstract

Titanium and its alloys have superior electrochemical properties compared to other alloy systems due to the formation of a protective TiO2 film on metal surfaces. The ability to generate the protective oxide layer will depend upon the type of alloy to be used. The aim of this work was to characterize the electrochemical corrosion behavior of titanium Ti-CP2 and alloys Ti-6Al-2Sn-4Zr-2Mo, Ti-6Al-4V, and Ti Beta-C. Samples were anodized in 1 M H2SO4 and H3PO4 solutions with a current density of 0.025 A/cm2. Electrochemical tests on anodized alloys were carried out using a three-electrode cell and exposed in two electrolytes, i.e., 3.5 wt % NaCl and 3.5 wt % H2SO4 solutions at room temperature. Scanning electron microscopy (SEM) was used to observe the morphology of anodized surfaces. The electrochemical techniques used were cyclic potentiodynamic polarization (CPP) and electrochemical noise (EN), based on the ASTM-G61 and G199 standards. Regarding EN, two methods of data analysis were used: the frequency domain (power spectral density, PSD) and time-frequency domain (discrete wavelet transform). For non-anodized alloys, the results by CCP and EN indicate icorr values of ×10−6 A/cm2. However, under anodizing conditions, the icorr values vary from ×10−7 to ×10−9 A/cm2. The PSD Ψ0 values are higher for non-anodized alloys, while in anodized conditions, the values range from −138/−122 dBi (A2·Hz−1)1/2 to −131/−180 dBi (A2·Hz−1)1/2. Furthermore, the results indicated that the alloys anodized in the H3PO4 bath showed an electrochemical behavior that can be associated with a more homogeneous passive layer when exposed to the 3.5 wt % NaCl electrolyte. Alloys containing more beta-phase stabilizers formed a less homogeneous anodized layer. These alloys are widely used in aeronautical applications; thus, it is essential that these alloys have excellent corrosion performance in chloride and acid rain environments.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition · Welding Techniques and Residual Stresses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Universidad Autonoma de Nuevo Leon, FIME-Centro de Investigación e Innovación en Ingeniería Aeronáutica (CIIIA), Av. Universidad s/n, Ciudad Universitaria, San Nicolás de los Garza 66455, Mexico

Department of Metallurgy and Structural Integrity, Centro de Investigación en Materiales Avanzados (CIMAV), Miguel de Cervantes 120, Complejo Industrial Chihuahua, Chihuahua 31136, Mexico

Facultad de Ingeniería Civil, Universidad Veracruzana, Xalapa 91000, Mexico

Department Metal-Mechanical, Tecnológico Nacional de Mexico-Instituto Tecnológico de Chihuahua, Av. Tecnologico 2909, Chihuahua 31130, Mexico

Department of Innovation Engineering, University of Salento, via per Monteroni, 73100 Lecce, Italy

References (98)

Show source-provided references
1. Anodization of titanium alloys for orthopedic applications10.1007/s11705-018-1759-y ↗
2. Gloria, A., Montanari, R., Richetta, M., and Varone, A. (2019). Alloys for aeronautic applications: State of the art and perspectives. Metals, 9.10.3390/met9060662 ↗
3. Titanium alloys for aerospace applications10.1002/adem.200310095 ↗
4. Properties and applications of titanium alloys: A brief review
5. Synergistic interactions between corrosion and wear at titanium-based dental implant connections: A scoping review10.1111/jre.12469 ↗
6. Is there scientific evidence favoring the substitution of commercially pure titanium with titanium alloys for the manufacture of dental implants?10.1016/j.msec.2016.10.025 ↗
7. Can degradation products released from dental implants affect peri-implant tissues?
8. Bocchetta, P., Chen, L.-Y., Tardelli, J.D.C., Reis, A.C.D., Almeraya-Calderón, F., and Leo, P. (2021). Passive layers and corrosion resistance of biomedical Ti-6Al-4V and β-Ti alloys. Coatings, 11.10.3390/coatings11050487 ↗
9. Preparation and characterization of TiO2 thin films by sol-gel method10.1023/A:1019912312654 ↗
10. Effect of thermal oxidation on titanium oxides characteristics10.1080/17458080902769937 ↗
11. Nucleation and growth in TiO2 films prepared by sputtering and evaporation10.1016/0040-6090(94)90843-5 ↗
12. Deposition of thin TiO2 layers on platinum by means of cyclic voltammetry of selected complex Ti (IV) media leading to anatase10.1016/j.electacta.2009.02.036 ↗
13. Oxidation mechanism of biomedical titanium alloy surface and experiment10.1155/2020/1678615 ↗
14. Reactivity of porous titanium oxidefilm and chitosan layer electrochemically formed on Ti-6Al-4V alloy in biological solution10.1016/j.surfcoat.2018.09.015 ↗
15. Surface modification of titanium and titanium alloys: Technologies, developments, and future interests10.1002/adem.201901258 ↗
16. Influence of chemical composition on cell viability on titanium surfaces: A systematic review10.1016/j.prosdent.2020.02.001 ↗
17. Surface damage of dental implant systems and ions release after exposure to fluoride and hydrogen peroxide
18. Michalska-Domanska, M., Łazinska, M., Łukasiewicz, J., Mol, J.M.C., and Durejko, T. (2020). Self-organized anodic oxides on titanium alloys prepared from glycol- and glycerol-based electrolytes. Materials, 13.10.3390/ma13214743 ↗
19. Local drug delivery to the bone by drug-releasing implants: Perspectives of nano-engineered titania nanotube arrays10.4155/tde.12.66 ↗
20. Characterization of the morphology, structure and wettability of phase dependent lamellar and nanotube oxides on anodized Ti-10Nb alloy10.1016/j.apsusc.2018.04.079 ↗
21. Characterization and photocatalytic properties of nanoporous titanium dioxide layer fabricated on pure titanium substrates by the anodic oxidation process10.1016/j.ceramint.2013.07.046 ↗
22. Corrosion behavior of AISI 409Nb stainless steel manufactured by powder metallurgy exposed in H2SO4 and NaCl solutions10.1016/S1452-3981(23)14041-7 ↗
23. The Hilbert–Huang transform-based denoising method for the TEM response of a PRBS source signal10.1007/s00024-016-1308-x ↗
24. Galvanic corrosion of titanium coupled to welded titanium in LiBr solutions at different temperatures10.1016/j.corsci.2009.02.023 ↗
25. Synergistic effects of fluoride and chloride on general corrosion behavior of AISI 316 stainless steel and pure titanium in H2SO4 solutions10.1016/j.corsci.2017.10.028 ↗
26. Anodically grown fuctional oxide nanotubes and applications10.1557/mrc.2016.46 ↗
27. Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown10.1016/S0142-9612(01)00131-4 ↗
28. Corrosion behavior and surface characterization of titanium in solution containing fluoride and albumin10.1016/j.biomaterials.2004.03.025 ↗
29. A review of growth mechanism, structure and crystallinity of anodized TiO2 nanotubes10.1016/j.mser.2013.10.001 ↗
30. Macro, micro and nanostructure of TiO2 anodised films prepared in a fluorine-containing electrolyte10.1007/s10853-006-1474-9 ↗
31. Effect of surface nanocrystallization on the corrosion behavior of Ti-6Al-4V titanium alloy10.1016/j.surfcoat.2013.02.052 ↗
32. Removing loose oxide layer and producing dense α-phase layer simultaneously to improve corrosion resistance of Ti-6Al-4V titanium alloy by coupling electrical pulse and ultrasonic treatment10.1016/j.surfcoat.2019.125329 ↗
33. Risking, J. (2019). Electrocorrosion and Protection of Metals, Elsevier. [2nd ed.].
34. Electrochemical corrosion of titanium and titanium-based alloys10.1067/mpr.2001.113029 ↗
35. Electrochemical corrosion behavior of titanium-zirconium-molybdenum alloy10.1016/S1875-5372(17)30141-8 ↗
36. Jaquez-Muñoz, J., Gaona-Tiburcio, C., Lira-Martinez, A., Zambrano-Robledo, P., Maldonado-Bandala, E., Samaniego-Gamez, O., Nieves-Mendoza, D., Olguin-Coca, J., Estupiñan-Lopez, F., and Almeraya-Calderon, F. (2021). Susceptibility to pitting corrosion of Ti-CP2, Ti-6Al-2Sn-4Zr-2Mo, and Ti-6Al-4V alloys for aeronautical applications. Metals, 11.10.3390/met11071002 ↗
37. Jáquez-Muñoz, J.M., Gaona-Tiburcio, C., Cabral-Miramontes, J., Nieves-Mendoza, D., Maldonado-Bandala, E., Olguín-Coca, J., López-Léon, L.D., Flores-De los Rios, J.P., and Almeraya-Calderón, F. (2021). Electrochemical noise analysis of the corrosion of titanium alloys in NaCl and H2SO4 solutions. Metals, 11.10.3390/met11010105 ↗
38. A novel experimental arrangement for corrosión study of X60 pipeline steel weldments at turbulent flow conditions10.1080/1478422X.2015.1124598 ↗
39. Corrosion study of the X52 steel immersed in seawater with a corrosion inhibitor using a rotating cylinder electrode10.1002/maco.200905441 ↗
40. Passivity breakdown, pit initiation and propagation of pits in metallic materials—Review10.1016/j.corsci.2014.10.006 ↗
41. Wandelt, K. (2016). Corrosion of Titanium, and Its Alloys, Elsevier. [1st ed.].
42. Effects of competitive anion adsorption (Br− or Cl−) and semiconducting properties of the passive films on the corrosion behavior of the additively manufactured Ti-6Al-4V alloys10.1016/j.corsci.2020.108789 ↗
43. Über die polarization bei kathodischer wasserstoffentwicklung10.1515/zpch-1905-5043 ↗
44. Electrochemical and tribological behavior of surface-treated titanium alloy Ti-6Al-4V10.1007/s40735-018-0193-5 ↗
45. Orazem, E.N., and Tribollet, B. (2017). Electrochemical Impedance Spectroscopy, John Wiley & Sons, Inc.10.1002/9781119363682 ↗
46. Wagner, C., and Traud, W. (1951). Über die Deutung von Korrosionsvorgängen durch Überlagerung von Elektrochemischen Teilvorgängen und über die Potentialbildung an Mischelektroden, Z. Elektrochem, Springer.
47. Studies in heterogeneous equilibria. Part II—The kinetic interpretation on the Nernst theory of electromotive force10.1039/TF9241900729 ↗
48. Evaluation of corrosion inhibitors by electrochemical noise analysis10.1149/1.2069288 ↗
49. Electrochemical noise analysis of localized corrosion of duplex stainless steel aged at 475 °C10.1016/j.matchemphys.2004.11.039 ↗
50. Electrochemical noise analysis of pitting corrosion of type 304L stainless steel10.5006/1003 ↗
51. Kearns, J.R., Scully, J.R., Roberge, P.R., Reirchert, D.L., and Dawson, L. (1996). Electrochemical Noise Measurement for Corrosion Applications STP 1277, ASTM International, Materials Park.10.1520/STP1277-EB ↗
52. Eden, D.A. (1998). Corrosion/98, NACE.
53. Nanoprecipitation in a beta-titanium alloy10.1016/j.jallcom.2014.10.038 ↗
54. ASTM E3-95 (1995). Standard Practice for Preparation of Metallographic Specimens, ASTM International.
55. ASTM E407-07 (2011). Standard Practice for Microetching Metals and Alloys, ASTM International.
56. AMS2487 (2018). Anodic Treatment of Titanium and Titanium Alloys Solution pH 12.4 Maximum, SAE International.
57. Cabral-Miramontes, J., Gaona-Tiburcio, C., Estupinán-López, F., Lara-Banda, M., Zambrano-Robledo, P., Nieves-Mendoza, D., Maldonado-Bandala, E., Chacón-Nava, J., and Almeraya-Calderón, F. (2020). Corrosion resistance of hard coat anodized AA 6061 in citric–sulfuric solutions. Coatings, 10.10.3390/coatings10060601 ↗
58. Parameter studies on high-velocity oxy-fuel spraying of CoNiCrAlY coatings used in the aeronautical industry
59. ASTM G5-11 (2011). Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements, ASTM International.
60. ASTM G61-86 (2018) (2018). Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements for Localized Corrosion Susceptibility of Iron-, Nickel-, or Cobalt-Based Alloys, ASTM International.
61. Lara-Banda, M., Gaona-Tiburcio, C., Zambrano-Robledo, P., Delgado, E.M., Cabral-Miramontes, J.A., Nieves-Mendoza, D., Maldonado-Bandala, E., Estupiñan-López, F., Chacón-Nava, J.G., and Almeraya-Calderón, F. (2020). Alternative to nitric acid passivation of 15-5 and 17-4PH stainless steel using electrochemical techniques. Materials, 13.10.3390/ma13122836 ↗
62. An integrated approach in the time, frequency and time-frequency domain for the identification of corrosion using electrochemical noise10.1016/j.electacta.2016.11.018 ↗
63. Electrochemical noise analysis of nickel based superalloys in acid solutions10.1016/S1452-3981(23)07736-2 ↗
64. Montoya-Rangel, M., de Garza-Montes, O.N., Gaona-Tiburcio, C., Colás, R., Cabral-Miramontes, J., Nieves-Mendoza, D., Maldonado-Bandala, E., Chacón-Nava, J., and Almeraya-Calderón, F. (2020). Electrochemical noise measurements of advanced high-strength steels in different solutions. Metals, 10.10.3390/met10091232 ↗
65. Kearns, J.R., Scully, J.R., Roberge, P.R., Reirchert, D.L., and Dawson, L. (1996). Electrochemical Noise Measurement for Corrosion Applications STP 1277, ASTM International, Materials Park.10.1520/STP1277-EB ↗
66. ASTM G199-09 (2009). Standard Guide for Electrochemical Noise Measurement, ASTM International.
67. Froes, F., and Quian, M. (2019). Titanium for Consumer Applications. Real World Use of Titanium, Elsevier Inc.
68. The influence of pore morphology on corrosion10.1016/S0010-938X(97)00152-2 ↗
69. Electrochemical study of effect of the concentration of azole derivatives on corrosion behavior of stainless steel in H2SO410.1016/j.porgcoat.2014.05.023 ↗
70. Noise analysis applied to electrochemical systems10.5006/1.3293585 ↗
71. Noise resistance applied to corrosion measurements: II10.1149/1.1837362 ↗
72. Detection of corrosion degradation using electrochemical noise (EN): Review of signal processing methods for identifying corrosion forms
73. Analysis of electrochemical noise data for a passive system in the frequency domain10.1016/S0010-938X(98)00033-X ↗
74. Corrosion monitoring system based on measurement and analysis of electrochemical noise10.5006/1.3293594 ↗
75. Transient analysis of electrochemical noise for 316 and duplex 2205 stainless steels under pitting corrosion10.1016/S1452-3981(23)18146-6 ↗
76. Combating marine corrosion on engineered oxide surface by repelling, blocking and capturing Cl−: Mini review10.1016/j.corcom.2021.09.001 ↗
77. Chloride ion penetrability and corrosion behavior of steel in concrete with sustainability characteristics10.1016/S1452-3981(23)15047-4 ↗
78. Oxidation performance of a Fe–13Cr alloy with additions of rare earth elements10.1016/S0921-5093(03)00346-0 ↗
79. Sulfate attack and reinforcement corrosion in concrete with recycled concrete aggregates and supplementary cementing materials10.1016/S1452-3981(23)15020-6 ↗
80. An electrochemical study of the corrosion behavior of a dual phase steel in 0.5m H2SO410.1016/S1452-3981(23)15384-3 ↗
81. Monododecyk phosphate film on LY12 aluminum alloy: pH-Controlled self-assembly and corrosion resistance10.1149/1945-7111/abd3bb ↗
82. Corrosion of titanium: Part 1: Aggressive environments and man forms of degradation
83. The effects of spark anodizing treatment of pure titanium metals and titanium alloys on corrosion characteristics10.1016/j.surfcoat.2006.11.022 ↗
84. A critical appraisal of the interpretation of electrochemical noise for corrosion studies10.5006/1277 ↗
85. Effect of multi-pass friction stir processing on the electrochemical and corrosion behavior of pure titanium in strongly acidic solutions10.1007/s11661-016-3854-3 ↗
86. Effect of porosity on mechanical and electrochemical properties of Ti-6Al-4V alloy10.1016/j.electacta.2020.135858 ↗
87. Pure commercial titanium color anodizing and corrosion resistance10.1007/s11665-011-9860-0 ↗
88. Pitting corrosion on anodized titanium: Effect of halides10.1002/maco.201810171 ↗
89. Corrosion of titanium: Part 1: Effects of surface treatments
90. Electrochemical anodizing treatment to enhance localized corrosion resistance of pure titanium
91. Preparation and characterization of porous bioceramic layers on pure titanium surface obtained by micro-arc oxidation process10.1007/s00339-017-0765-0 ↗
92. Self-organized and uniform TiO2 nanotube arrays with optimized NH4F concentration in electrolyte by high voltage electrochemical anodization10.1088/2053-1591/aac1f5 ↗
93. Fabrication of a TiO2 photocatalyst by anodic oxidation of Ti in an acetic acid electrolyte10.1016/j.surfcoat.2013.12.030 ↗
94. Incorporation of Ca and P on anodized titanium surface: Effect of high current density10.1016/j.msec.2014.01.006 ↗
95. Simulation of anodizing current-time curves and morphology evolution of TiO2 nanotubes anodized in electrolytes with different NH4F concentrations10.1016/j.electacta.2015.07.110 ↗
96. Anodic growth of titanium oxide: Electrochemical behaviour and morphological evolution10.1016/j.electacta.2012.04.114 ↗
97. Spark anodising of titanium for biomedical applications
98. EVect of anodic oxidation parameters on the titanium oxides formatio10.1016/j.corsci.2006.04.002 ↗