Micro-Arc Oxidation in Titanium and Its Alloys: Development and Potential of Implants
Source abstract
Abstract
Titanium (Ti) and its alloys are widely recognized as preferred materials for bone implants due to their superior mechanical properties. However, their natural surface bio-inertness can hinder effective tissue integration. To address this challenge, micro-arc oxidation (MAO) has emerged as an innovative electrochemical surface modification technique. Its benefits range from operational simplicity and cost-effectiveness to environmental compatibility and scalability. Furthermore, the distinctive MAO process yields a porous topography that bestows versatile functionalities for biological applications, encompassing osteogenesis, antibacterial, and anti-inflammatory properties. In this review, we undertake an examination of the underlying mechanism governing the MAO process, scrutinize the multifaceted influence of various factors on coating performance, conduct an extensive analysis of the development of diverse biological functionalities conferred by MAO coatings, and discuss the practical application of MAO in implants. Finally, we provide insights into the limitations and potential pathways for further development of this technology in the field of bone implantation.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Magnesium Alloys: Properties and Applications · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Materials Science and Engineering, Beihang University, Beijing 100191, China
Zhongfa Aviation Institute, Beihang University, Hangzhou 311115, China
Institute of Translational Medicine, Shanghai University, Shanghai 200444, China
Funding
National Key Research and Development Program of China
References (100+)
Show source-provided references
1. Vereinte, N. (2023). Leaving No One Behind in an Ageing World, United Nations. World social report.
2. Jing, Z., Zhang, T., Xiu, P., Cai, H., Wei, Q., Fan, D., Lin, X., Song, C., and Liu, Z. (2020). Functionalization of 3D-printed titanium alloy orthopedic implants: A literature review. Biomed. Mater., 15.10.1088/1748-605X/ab9078 ↗
3. Jimenez-Marcos, C., Mirza-Rosca, J.C., Baltatu, M.S., and Vizureanu, P. (2022). Experimental Research on New Developed Titanium Alloys for Biomedical Applications. Bioengineering, 9.10.3390/bioengineering9110686 ↗
4. Microstructure and mechanical properties of hot-extruded Mg–2Zn-xGa (x = 1, 3, 5 and 7 wt.%) alloys10.1016/j.msea.2022.144208 ↗
5. Effects of annealing temperature on microstructures and shape memory effect of Ti-19Zr-11Nb-2Ta alloy sheets10.1016/j.jallcom.2021.162728 ↗
6. In vitro electrochemical properties of biodegradable ZrO2-CaO coated MgCa alloy using atmospheric plasma spraying
7. Corrosion resistance and cytocompatibility of Ti-20Zr-10Nb-4Ta alloy surface modified by a focused fiber laser10.1007/s40843-017-9239-3 ↗
8. Wu, Y., Li, Q., Xu, B., Fu, H., and Li, Y. (2021). Nano-hydroxyapatite coated TiO2 nanotubes on Ti-19Zr-10Nb-1Fe alloy promotes osteogenesis in vitro. Colloids Surf. B Biointerfaces, 207.10.1016/j.colsurfb.2021.112019 ↗
9. Di Pompo, G., Liguori, A., Carlini, M., Avnet, S., Boi, M., Baldini, N., Focarete, M.L., Bianchi, M., Gualandi, C., and Graziani, G. (2023). Electrospun fibers coated with nanostructured biomimetic hydroxyapatite: A new platform for regeneration at the bone interfaces. Biomater. Adv., 144.10.1016/j.bioadv.2022.213231 ↗
10. Enzymatic pH control for biomimetic deposition of calcium phosphate coatings10.1016/j.actbio.2013.09.036 ↗
11. Review of micro-arc oxidation of titanium alloys: Mechanism, properties and applications10.1016/j.jallcom.2023.169773 ↗
12. Biocompatibility and osteoconduction of active porous calcium–phosphate films on a novel Ti–3Zr–2Sn–3Mo–25Nb biomedical alloy10.1016/j.colsurfb.2011.02.025 ↗
13. Mechanical properties of anodic titanium films containing ions of Ca and P submitted to heat and hydrothermal treatment10.1016/j.jmbbm.2016.07.019 ↗
14. Surface modification of severe plastically deformed ultrafine grained pure titanium by plasma electrolytic oxidation10.1016/j.surfcoat.2017.03.016 ↗
15. Characterization of plasma electrolytic oxidation film on biomedical high niobium-containing β-titanium alloy10.1016/j.surfcoat.2018.08.025 ↗
16. Lederer, S., Arat, S., and Fuerbeth, W. (2021). Influence of Process Parameters on the Tribological Behavior of PEO Coatings on CP-Titanium 4+ Alloys for Biomedical Applications. Materials, 14.10.3390/ma14185364 ↗
17. Formation of bioactive hydroxyapatite-containing titania coatings on CP-Ti 4+ alloy generated by plasma electrolytic oxidation10.1016/j.surfcoat.2019.02.030 ↗
18. Functional State of Mesenchymal Stem Cells upon Exposure to Bioactive Coatings on Titanium Alloys10.1007/s10517-020-04841-6 ↗
19. Recent advances in electrochemically surface treated titanium and its alloys for biomedical applications: A review of anodic and plasma electrolytic oxidation methods10.1016/j.mtcomm.2023.105425 ↗
20. Review of plasma electrolytic oxidation of titanium substrates: Mechanism, properties, applications and limitations10.1016/j.apsadv.2021.100121 ↗
21. Jiang, B.L., and Wang, Y.M. (2010). Surface Engineering of Light Alloys, Elsevier.
22. Recent progress in surface modification of metals coated by plasma electrolytic oxidation: Principle, structure, and performance10.1016/j.pmatsci.2020.100735 ↗
23. Electrochemical surface engineering of titanium-based alloys for biomedical application10.1016/j.electacta.2018.03.180 ↗
24. A theory of avalanche breakdown during anodic oxidation10.1016/0013-4686(87)85032-6 ↗
25. Discharge characterization in plasma electrolytic oxidation of aluminium10.1088/0022-3727/36/17/314 ↗
26. Characterization of the plasma electrolytic oxidation of titanium in sodium metasilicate10.1016/j.apsusc.2012.10.183 ↗
27. Plasma electrolytic oxidation of titanium in heteropolytungstate acids10.1016/j.surfcoat.2011.07.090 ↗
28. Processing-Microstructure Relationships in the Plasma Electrolytic Oxidation (PEO) Coating of a Magnesium Alloy
29. Review of the biocompatibility of micro-arc oxidation coated titanium alloys10.1016/j.matdes.2015.07.086 ↗
30. Effect of electrolyte composition on the microstructure and bio-corrosion behavior of micro-arc oxidized coatings on biomedical Ti6Al4V alloy10.1016/j.jmrt.2019.11.073 ↗
31. Liu, W., Liu, S., and Wang, L. (2019). Surface Modification of Biomedical Titanium Alloy: Micromorphology, Microstructure Evolution and Biomedical Applications. Coatings, 9.10.3390/coatings9040249 ↗
32. Precipitation of bone-like apatite on plasma electrolytic oxidized Ti-6Al-4V alloy10.1016/j.tsf.2022.139136 ↗
33. Rakhadilov, B., and Baizhan, D. (2021). Creation of Bioceramic Coatings on the Surface of Ti–6Al–4V Alloy by Plasma Electrolytic Oxidation Followed by Gas Detonation Spraying. Coatings, 11.10.3390/coatings11121433 ↗
34. Correlations between the growth mechanism and properties of micro-arc oxidation coatings on titanium alloy: Effects of electrolytes10.1016/j.surfcoat.2017.03.021 ↗
35. Formation and in vitro/in vivo performance of “cortex-like” micro/nano-structured TiO2 coatings on titanium by micro-arc oxidation
36. Formation and cytocompatibility of a hierarchical porous coating on Ti-20Zr-10Nb-4Ta alloy by micro-arc oxidation10.1016/j.surfcoat.2020.126471 ↗
37. Formation of plasma electrolytic oxidation coatings on pure niobium in different electrolytes10.1016/j.apsusc.2021.151629 ↗
38. Morphology and phase composition of MAO ceramic coating containing Cu on Ti6Al4V alloy10.1007/s12598-014-0291-6 ↗
39. Effect of Electrolyte Composition on Photocatalytic Activity and Corrosion Resistance of Micro-Arc Oxidation Coating on Pure Titanium10.1016/j.proeps.2011.09.026 ↗
40. Zhang, R., Zhong, S., Zeng, L., Li, H., Zhao, R., Zhang, S., Duan, X., Huang, J., and Zhao, Y. (2021). Novel Mg-Incorporated Micro-Arc Oxidation Coatings for Orthopedic Implants Application. Materials, 14.10.3390/ma14195710 ↗
41. Preparation and formation mechanism of copper incorporated micro-arc oxidation coatings developed on Ti-6Al-4V alloys10.1016/j.surfcoat.2019.06.096 ↗
42. Influence of Concentration of Potassium Hydroxide in Electrolyte on Formation of Hydroxyapatite Coatings on Titanium10.1007/s11837-023-06056-2 ↗
43. Effect of sodium silicate concentration on the physico-chemical properties of dual-setting bone-like apatite cements10.1016/j.mtcomm.2022.103421 ↗
44. Influence of electrolyte ageing on the Plasma Electrolytic Oxidation of aluminium10.1016/j.surfcoat.2014.11.001 ↗
45. Electrolyte influence on ignition of plasma electrolytic oxidation processes on light metals10.1016/j.surfcoat.2017.02.041 ↗
46. Highly corrosion protection properties of plasma electrolytic oxidized titanium using rGO nanosheets10.1016/j.apsusc.2019.05.026 ↗
47. The effects of nano- and micro-particles on properties of plasma electrolytic oxidation (PEO) coatings applied on titanium substrates: A review10.1016/j.surfin.2020.100659 ↗
48. Biofunctionalization of metallic implants by calcium phosphate coatings
49. Shen, X., Hu, W., Ping, L., Liu, C., Yao, L., Deng, Z., and Wu, G. (2020). Antibacterial and Osteogenic Functionalization of Titanium with Silicon/Copper-Doped High-Energy Shot Peening-Assisted Micro-Arc Oxidation Technique. Front. Bioeng. Biotechnol., 8.10.3389/fbioe.2020.573464 ↗
50. Calcium Phosphate-Based Composite Coating by Micro-Arc Oxidation (MAO) for Biomedical Application: A Review10.1080/10408436.2017.1358148 ↗
51. Shimabukuro, M. (2020). Antibacterial Property and Biocompatibility of Silver, Copper, and Zinc in Titanium Dioxide Layers Incorporated by One-Step Micro-Arc Oxidation: A Review. Antibiotics, 9.10.3390/antibiotics9100716 ↗
52. Enrichment of anodic MgO layers with Ag nanoparticles for biomedical applications10.1007/s10856-008-3589-9 ↗
53. Plasma electrolysis for surface engineering10.1016/S0257-8972(99)00441-7 ↗
54. Insights into plasma electrolytic oxidation treatment with particle addition10.1016/j.corsci.2015.09.016 ↗
55. Effects of the sources of calcium and phosphorus on the structural and functional properties of ceramic coatings on titanium dental implants produced by plasma electrolytic oxidation10.1016/j.msec.2020.111607 ↗
56. Effect of ultra accurate control of electrolyte temperature on the performance of micro arc oxidation ceramic coatings10.1016/j.ceramint.2023.08.032 ↗
57. Spark anodizing behaviour of titanium and its alloys in alkaline aluminate electrolyte10.1016/j.corsci.2008.10.021 ↗
58. The incorporation of particles suspended in the electrolyte into plasma electrolytic oxidation coatings on Ti and Al substrates10.1016/j.surfcoat.2020.125354 ↗
59. Sikdar, S., Menezes, P.V., Maccione, R., Jacob, T., and Menezes, P.L. (2021). Plasma Electrolytic Oxidation (PEO) Process—Processing, Properties, and Applications. Nanomaterials, 11.10.3390/nano11061375 ↗
60. Plasma Electrolytic Oxidation Coatings on Aluminum Alloys: Microstructures, Properties, and Applications
61. Surface modification of titanium and titanium alloy by plasma electrolytic oxidation process for biomedical applications: A review
62. The effect of current mode and discharge type on the corrosion resistance of plasma electrolytic oxidation (PEO) coated magnesium alloy AJ6210.1016/j.surfcoat.2011.08.060 ↗
63. Direct current micro-arc oxidation coatings on Al-Zn-Mg-Mn-Zr extruded alloy with tunable structures and properties templated by discharge stages10.1016/j.vacuum.2018.01.040 ↗
64. Phenomena of nano-particle formation in the plasma electrolytic oxidation process according to applied potentials10.1007/s13204-022-02683-4 ↗
65. Effects of current frequency on the structural characteristics and corrosion property of ceramic coatings formed on magnesium alloy by PEO technology10.1016/j.jmatprotec.2007.12.125 ↗
66. Effect of frequency on the structure and cell response of Ca- and P-containing MAO films10.1016/j.apsusc.2009.09.041 ↗
67. Effect of duty cycle and applied current frequency on plasma electrolytic oxidation (PEO) coating growth behavior10.1016/j.surfcoat.2013.03.041 ↗
68. The plasma electrolytic oxidation (PEO) coatings to enhance in-vitro corrosion resistance of Ti–29Nb–13Ta–4.6Zr alloys: The combined effect of duty cycle and the deposition frequency10.1016/j.surfcoat.2019.06.025 ↗
69. Effect of duty cycle and electrolyte additive on photocatalytic performance of TiO2-ZrO2 composite layers prepared on CP Ti by micro arc oxidation method10.1016/j.surfcoat.2016.09.050 ↗
70. Influence of frequency and duty cycle on the properties of antibacterial borate-based PEO coatings on titanium for bone-contact applications10.1016/j.apsusc.2021.150811 ↗
71. The effects of anodic and cathodic processes on the characteristics of ceramic coatings formed on titanium alloy through the MAO coating technology10.1016/j.apsusc.2005.01.023 ↗
72. Effects of cathode pulse at high frequency on structure and composition of Al2TiO5 ceramic coatings on Ti alloy by plasma electrolytic oxidation10.1016/j.matchemphys.2010.11.035 ↗
73. Composition and mechanical properties of hard ceramic coating containing α-Al2O3 produced by microarc oxidation on Ti–6Al–4V alloy10.1016/j.tsf.2004.06.096 ↗
74. An investigation of microstructure evolution for plasma electrolytic oxidation (PEO) coated Al in an alkaline silicate electrolyte10.1016/j.surfcoat.2018.07.055 ↗
75. Tang, Q., Qiu, T., Ni, P., Zhai, D., and Shen, J. (2022). Soft Sparking Discharge Mechanism of Micro-Arc Oxidation Occurring on Titanium Alloys in Different Electrolytes. Coatings, 15.10.3390/coatings12081191 ↗
76. Growth pattern of soft-spark micro-arc oxide coating on titanium alloy in silicon anion electrolyte10.1016/j.surfcoat.2023.130030 ↗
77. Antibacterial properties and cytocompatibility of Ti-20Zr-10Nb-4Ta alloy surface with Ag microparticles by laser treatment10.1016/j.surfcoat.2021.127716 ↗
78. Micro-arc oxidation of β-titanium alloy: Structural characterization and osteoblast compatibility10.1016/j.surfcoat.2009.06.043 ↗
79. Micro-arc oxidation of Ti6Al4V and Ti6Al7Nb alloys for biomedical applications10.1016/j.matchar.2011.01.002 ↗
80. The influence of alloy elements in Ti6Al4V and Ti35Nb2Ta3Zr on the structure, morphology and properties of MAO coatings10.1016/j.vacuum.2018.08.054 ↗
81. Corrosion behavior and mechanism of MAO coated Ti6Al4V with a grain-fined surface layer10.1016/j.jallcom.2015.12.108 ↗
82. Effects of ageing treatment on corrosion behavior of 7075 aluminum alloy coated by micro arc oxidation (MAO)10.1016/j.corsci.2022.110164 ↗
83. Surface modification of biomaterials and biomedical devices using additive manufacturing10.1016/j.actbio.2017.11.003 ↗
84. Chen, K.-T., Huang, J.-W., Lin, W.-T., Kuo, T.-Y., Chien, C.-S., Chang, C.-P., and Lin, Y.-D. (2023). Effects of Micro-Arc Oxidation Discharge Parameters on Formation and Biomedical Properties of Hydroxyapatite-Containing Flower-like Structure Coatings. Materials, 16.10.3390/ma16010057 ↗
85. Toward rational design of ceramic coatings generated on valve metals by plasma electrolytic oxidation: The role of cathodic polarisation10.1016/j.ceramint.2021.08.324 ↗
86. Characteristics and in vitro response of thin hydroxyapatite–titania films produced by plasma electrolytic oxidation of Ti alloys in electrolytes with particle additions10.1039/C5RA22178A ↗
87. Formation and characterization of wear-resistant PEO coatings formed on β-titanium alloy at different electrolyte temperatures10.1016/j.apsusc.2012.07.104 ↗
88. Kuroda, P.A.B., Grandini, C.R., and Afonso, C.R.M. (2023). Surface Characterization of New β Ti-25Ta-Zr-Nb Alloys Modified by Micro-Arc Oxidation. Materials, 16.10.3390/ma16062352 ↗
89. Nano-Architectural Approaches for Improved Intracortical Interface Technologies10.3389/fnins.2018.00456 ↗
90. Stich, T., Alagboso, F., Křenek, T., Kovářík, T., Alt, V., and Docheva, D. (2022). Implant-bone-interface: Reviewing the impact of titanium surface modifications on osteogenic processes in vitro and in vivo. Bioeng. Transl. Med., 7.10.1002/btm2.10239 ↗
91. A Retrospective Study of the Survival of Smooth- and Rough-Surface Dental Implants
92. Osseointegration and current interpretations of the bone-implant interface10.1016/j.actbio.2018.11.018 ↗
93. Hanawa, T. (2019). Titanium–Tissue Interface Reaction and Its Control with Surface Treatment. Front. Bioeng. Biotechnol., 7.10.3389/fbioe.2019.00170 ↗
94. Role of pore size and morphology in musculo-skeletal tissue regeneration10.1016/j.msec.2015.12.087 ↗
95. Osteogenic response to porous hydroxyapatite ceramics under the skin of dogs10.1016/0142-9612(92)90054-R ↗
96. Implant Surface Roughness and Bone Healing: A Systematic Review10.1177/154405910608500603 ↗
97. Characterization and cytocompatibility of hierarchical porous TiO2 coatings incorporated with calcium and strontium by one-step micro-arc oxidation10.1016/j.msec.2019.110610 ↗
98. A super-hydrophilic coating with a macro/micro/nano triple hierarchical structure on titanium by two-step micro-arc oxidation treatment for biomedical applications10.1016/j.surfcoat.2016.12.065 ↗
99. Corrosion behaviors of bioactive element coatings on PEO-treated Ti-6Al-4V alloys10.1016/j.surfcoat.2018.07.093 ↗
100. A multifaceted coating on titanium dictates osteoimmunomodulation and osteo/angio-genesis towards ameliorative osseointegration10.1016/j.biomaterials.2018.02.010 ↗