journal article·2023Open access

Non-Contact Physiological Measurement System for Wearing Masks During the Epidemic

Shu-Yin Chiang, Dong-Ye Wu

Computers, Materials & Continua· Volume 75· Issue 2

Abstract

Physiological signals indicate a person’s physical and mental state at any given time. Accordingly, many studies extract physiological signals from the human body with non-contact methods, and most of them require facial feature points. However, under COVID-19, wearing a mask has become a must in many places, so how non-contact physiological information measurements can still be performed correctly even when a mask covers the facial information has become a focus of research. In this study, RGB and thermal infrared cameras were used to execute non-contact physiological information measurement systems for heart rate, blood pressure, respiratory rate, and forehead temperature for people wearing masks due to the pandemic. Using the green (G) minus red (R) signal in the RGB image, the region of interest (ROI) is established in the forehead and nose bridge regions. The photoplethysmography (PPG) waveforms of the two regions are obtained after the acquired PPG signal is subjected to the optical flow method, baseline drift calibration, normalization, and bandpass filtering. The relevant parameters in Deep Neural Networks (DNN) for the regression model can correctly predict the heartbeat and blood pressure. In addition, the temperature change in the ROI of the mask after thermal image processing and filtering can be used to correctly determine the number of breaths. Meanwhile, the thermal image can be used to read the temperature average of the ROI of the forehead, and the forehead temperature can be obtained smoothly. The experimental results show that the above-mentioned physiological signals of a subject can be obtained in 6-s images with the error for both heart rate and blood pressure within 2%~3% and the error of forehead temperature within ±0.5°C.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Optical Imaging and Spectroscopy Techniques · Infrared Thermography in Medicine

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. A thermal camera based continuous body temperature measurement system
2. Collaborative use of RGB and thermal imaging for remote breathing rate measurement under realistic conditions10.1016/j.infrared.2020.103504 ↗
3. Detection of respiratory infections using RGB-infrared sensors on portable device10.1109/JSEN.2020.3004568 ↗
4. Contactless vital signs measurement system using RGB-thermal image sensors and its clinical screening test on patients with seasonal influenza10.3390/s20082171 ↗
5. Remote sensing of multiple vital signs using a CMOS camera-equipped infrared thermography system and its clinical application in rapidly screening patients with suspected infectious diseases
6. Advancements in non-contact, multiparameter physiological measurements using a webcam
7. Measuring pulse rate with a webcam—a non-contact method for evaluating cardiac activity
8. A machine learning approach to improve contactless heart rate monitoring using a webcam
9. A novel nonintrusive decision support approach for heart rate measurement10.1016/j.patrec.2017.07.002 ↗
10. Relation between blood pressure and pulse wave velocity for human arteries10.1073/pnas.1814392115 ↗
11. Contactless blood pressure sensing using facial visible and thermal images10.1007/s10015-018-0450-1 ↗
12. Cuffless blood pressure estimation from only the waveform of photoplethysmography using CNN
13. Prospective studies collaboration. Age-specific relevance of usual blood pressure to vascular mortality: A meta-analysis of individual data for one million adults in 61 prospective studies
14. Robust blood pressure estimation using an RGB camera
15. Introducing contactless blood pressure assessment using a high speed video camera10.1007/s10916-016-0439-z ↗
16. Noncontact heart rate and blood pressure estimations from video analysis and machine learning modelling applied to food sensory responses: A case study for chocolate10.3390/s18061802 ↗
17. Non-contact blood pressure measurement based on IPPG10.32604/jnm.2021.017764 ↗
18. A blood pressure prediction method based on imaging photoplethysmography in combination with machine learning10.1016/j.bspc.2020.102328 ↗
19. Post-COVID-19 mask-aware face recognition system
20. MFCosface: A masked-face recognition algorithm based on large margin cosine loss10.3390/app11167310 ↗
21. SSDMNV2: A real time DNN-based face mask detection system using single shot multibox detector and MobileNetV210.1016/j.scs.2020.102692 ↗
22. Face mask invariant end-to-end face recognition
23. Towards mask-robust face recognition
24. Optimal filter estimation for Lucas-Kanade optical flow10.3390/s120912694 ↗
25. Y. -F. Chen, “Research on non-contact imaging measurement of heartbeat and blood pressure based on deep learning with arrhythmi,” Master Thesis, Ming Chuan University, Taiwan, 2021.