Abstract

The islanded mode is one of the connection modes of the grid distributed generation resources. In this study, a distributed generation resource is connected to linear and nonlinear loads via a three-phase inverter where a control method needing no current sensors or compensator elements is applied to the distribute generation system in the islanded mode. This control method has two main loops in each phase. The first loop controls the voltage control loops that adjust the three-phase point of common coupling, the amplitude of the non-sinusoidal reference waveform and the near-state pulse width modulation (NSPWM) method. The next loop compensatesthe harmonic compensator loop that calculates the voltage harmonics of the point of common coupling in each phase, and injects them to compensate the non-sinusoidal reference waveforms of each phase. The simulation results in MATLAB/SIMULINK show that this method can generate balanced three-phase sinusoidal voltage with an acceptable total harmonic distortion (THD) at the joint connection point.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Microgrid Control and Optimization · Advanced DC-DC Converters · Multilevel Inverters and Converters

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (47)

Show source-provided references
1. System performance improvement provided by a power conditioning subsystem for central station photovoltaic- fuel cell power plant10.1109/60.4201 ↗
2. Flexible distributed generation: (FDG)10.1109/PESS.2002.1043176 ↗
3. Control of grid-connected fuel cell plants for enhancement of power system stability10.1016/S0960-1481(02)00042-3 ↗
4. Two-loop controller for maximizing performance of a grid-connected photovoltaic-fuel cell hybrid power plant10.1109/60.707608 ↗
5. Utility interactive hybrid distribution generation scheme with compensation features10.1109/TEC.2006.878247 ↗
6. Micro-grid autonomous operation during and subsequent to islanding process10.1109/TPWRD.2004.835051 ↗
7. Parallel operation of voltage source inverters10.1109/28.2868 ↗
8. Interaction between distributed generation and the distribution network: Operation aspects10.1109/TDC.2002.1177677 ↗
9. Effect of harmonics on equipment10.1109/61.216874 ↗
10. Applications issues of active power filters
11. Perez · VIII IEEE International Power Electronics Congress · 2002 · 270
12. New approach to harmonic compensation in power systems-a combined system of shunt passive and series active filters10.1109/28.62380 ↗
13. A series active power filter adopting hybrid control approach10.1109/63.923761 ↗
14. A DSP based control algorithm for series active filter for optimized compensation under non-sinusoidal and unbalanced voltage conditions10.1109/TPWRD.2006.881460 ↗
15. Study of a simple control strategy for grid connected VSI using SVPWM and p-q theory
16. Comparative study between adaptive hysteresis and SVPWM current control for grid-connected inverter system
17. Study of advanced current control strategies for three-phase grid-connected PWM inverters for distributed generation
18. Control of a stand-alone inverter-based distributed generation source for voltage regulation and harmonic compensation10.1109/TPWRD.2007.915890 ↗
19. Processing characteristics of vegetable oil-based nanofluid MQL for grinding different workpiece materials10.1007/s40684-018-0035-4 ↗
20. Experimental assessment of an environmentally friendly grinding process using nanofluid minimum quantity lubrication with cryogenic air10.1016/j.jclepro.2018.05.009 ↗
21. Grinding temperature and energy ratio coefficient in MQL grinding of high-temperature nickel-base alloy by using different vegetable oils as base oil10.1016/j.cja.2015.10.012 ↗
22. Grindability of titanium alloy using cryogenic nanolubricant minimum quantity lubrication10.1016/j.jmapro.2022.06.003 ↗
23. Effect of combined air cooling and nano enhanced phase change materials on thermal management of lithium-ion batteries10.1016/j.est.2022.104906 ↗
24. Machinability of ultrasonic vibration assisted micro-grinding in biological bone using nanolubricant
25. Towards real-time self-powered sensing with ample redundant charges by a piezostack-based frequency-converted generator from human motions10.1016/j.enconman.2022.115466 ↗
26. Investigation of frequency-up conversion effect on the performance improvement of stack-based piezoelectric generators10.1016/j.renene.2021.03.064 ↗
27. Efficient smart grid load balancing via fog and cloud computing
28. Optimal performance of hybrid energy system in the presence of electrical and heat storage systems under uncertainties using stochastic p-robust optimization technique10.1016/j.scs.2022.103935 ↗
29. The multi-class fault diagnosis of wind turbine bearing based on multi-source signal fusion and deep learning generative model
30. Fixed-time-synchronized consensus control of multiagent systems10.1109/TCNS.2020.3034523 ↗
31. Power-frequency oscillation suppression algorithm for AC microgrid with multiple virtual synchronous generators based on fuzzy inference system10.1049/rpg2.12461 ↗
32. Electrochemical detection of nitrate with carbon nanofibers and copper co-modified carbon fiber electrodes10.1016/j.coco.2021.101043 ↗
33. Virtual synchronous generator of PV generation without energy storage for frequency support in autonomous microgrid10.1016/j.ijepes.2021.107343 ↗
34. An improved 3D point cloud instance segmentation method for overhead catenary height detection10.1016/j.compeleceng.2022.107685 ↗
35. Ore image classification based on improved CNN10.1016/j.compeleceng.2022.107819 ↗
36. Influences of wire diameters on output power in electromagnetic energy harvester
37. Investigation of transient magnetoelectric response of magnetostrictive/piezoelectric composite applicable for lightning current sensing10.1016/j.sna.2021.112789 ↗
38. Gear rotational speed sensor based on FeCoSiB/Pb(Zr,Ti)O3 magnetoelectric composite10.1016/j.measurement.2020.108409 ↗
39. Candidate modulation patterns solution for five-phase PMSM drive system10.1109/TTE.2021.3104876 ↗
40. Split-core magnetoelectric current sensor and wireless current measurement application10.1016/j.measurement.2021.110527 ↗
41. Virtual voltage vector based model predictive control for a nine-phase open-end winding PMSM with a common DC bus10.1109/TIE.2021.3088372 ↗
42. An optimization strategy of price and conversion factor considering the coupling of electricity and gas based on three-stage game
43. Voltage regulation with electric taxi based on dynamic game strategy10.1109/TVT.2022.3141954 ↗
44. Allocation of centrally switched fault current limiters enabled by 5G in transmission system10.1109/TPWRD.2020.3037193 ↗
45. A Multi-state model for transmission system resilience enhancement against short-circuit faults caused by extreme weather events10.1109/TPWRD.2020.3043938 ↗
46. Communication-efficient surrogate quantile regression for non-randomly distributed system10.1016/j.ins.2021.12.078 ↗
47. Design of a novel thermoelectric module based on application stability and power generation10.1016/j.csite.2022.101836 ↗