Evaluation of Pencil Lead Based Electrodes for Electrocardiogram Monitoring in Hot Spring
Source abstract
Abstract
Electrocardiogram (ECG) electrodes are conductive pads applied to the skin to measure cardiac activity. Ag/AgCl electrodes are the commercial product which widely used to obtain ECGs. When monitoring the ECG in a hot spring, Ag/AgCl electrodes must be waterproofed; however, this is time-consuming, and the adhesive may tear the skin on removal. For solving the problem, we developed the carbon pencil lead (CPL) electrodes for use in hot springs. Both CPL and Ag/AgCl electrodes were connected to ECG100C’s cables. The Performance was evaluated in three conditions as following: hot spring water with and without bubble, and in cold water. In each environment, the procedure was followed by three different protocols that are recording from the dry condition, hot spring water immersion with and without movement, post hot spring water condition. Under dry and wet conditions, both electrodes can obtain the waveform of the ECG signal in which all PQRST waves were identifiable. Nevertheless, the signal quality of both types of electrodes was different in water immersion with and without movement. The overall morphology obtained by Ag/AgCl electrodes was unstable higher than that of CPL electrodes in immersion without movement condition. The CPL electrodes provided better ECG waveform quality compared to Ag/AgCl electrodes in which the ECG signal had high waveforms distortion in water immersion with movement condition.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: ECG Monitoring and Analysis · EEG and Brain-Computer Interfaces · Non-Invasive Vital Sign Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Analysis of statistical methods for automatic detection of congestive heart failure and atrial fibrillation with short RR interval time series
2. Deep ensemble detection of congestive heart failure using short-term RR intervals10.1109/ACCESS.2019.2912226 ↗
3. Multiple time scales analysis for identifying congestive heart failure based on heart rate variability10.1109/ACCESS.2019.2895998 ↗
4. Classification tree for risk assessment in patients suffering from congestive heart failure via long-term heart rate variability10.1109/JBHI.2013.2244902 ↗
5. Combining convolutional neural network and distance distribution matrix for identification of congestive heart failure10.1109/ACCESS.2018.2855420 ↗
6. Atrial fibrillation detection using an iPhone 4S. IEEE transactions on biomedical engineering10.1109/TBME.2012.2208112 ↗
7. RR interval analysis for detection of atrial fibrillation in ECG monitors
8. The impact of the MIT-BIH Arrhythmia database10.1109/51.932724 ↗
9. A simple method to detect atrial fibrillation using RR intervals10.1016/j.amjcard.2011.01.028 ↗
10. Automatic detection of atrial fibrillation using RR interval signal
11. Robust detection of atrial fibrillation for a long term telemonitoring system
12. Heart rate variability on 7-day Holter monitoring using a bootstrap rhythmometric procedure10.1109/TBME.2010.2040899 ↗
13. A novel wearable device for continuous ambulatory ECG recording: Proof of concept and assessment of signal quality10.3390/bios9010017 ↗
14. Analyzing electrocardiogram signals obtained from a nymi band to detect atrial fibrillation10.1007/s11042-018-7075-1 ↗
15. A multiparameter wearable physiologic monitoring system for space and terrestrial applications10.1109/TITB.2005.854509 ↗
16. CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring10.1109/TBME.2012.2190288 ↗
17. Hypoxia and cardiac arrhythmias in breath-hold divers during voluntary immersed breath-holds10.1007/s00421-008-0945-x ↗
18. Autonomic nervous activity and stress hormones induced by hyperbaric saturation diving
19. Effects of severe hyperbaric pressure on autonomic nerve functions10.1093/milmed/167.11.934 ↗
20. Impairment of the autonomic nervous function during decompression sickness in swine10.1152/japplphysiol.91246.2008 ↗
21. Novel electrodes for underwater ECG monitoring10.1109/TBME.2014.2309293 ↗
22. What is a hot spring?10.1139/e03-083 ↗
23. Determination of hot springs physico-chemical water quality potentially use for balneotherapy
24. Effects of graphite porosity and anisotropy on measurements of elastic modulus using laser ultrasonics
25. Dry-contact and noncontact biopotential electrodes: Methodological review10.1109/RBME.2010.2084078 ↗
26. Graphite based electrode for ECG monitoring: Evaluation under freshwater and saltwater conditions10.3390/s16040542 ↗
27. BioPac, “MP160 data acquisition systems,” 2020. [Online]. Available: https://www.biopac.com/product/mp150-data-acquisition-systems/.
28. BioPac, “ECG electrocardiogram amplifier,” 2020. [Online]. Available: https://www.biopac.com/product/ecg-electrocardiogram-amplifier.
29. A review on the historical change of hot springs in Onyang-Oncheon
30. Onyang Hot Spring Hotel, “Onyang temporary palace/museum,” 2020. [Online]. Available: https://www.onyanghotel.co.kr:502/en/m92.php.
31. Hydrochemical properties of the onyang hot spring waters10.9720/kseg.2016.4.561 ↗
32. A comparison of the noise sensitivity of nine QRS detection algorithms10.1109/10.43620 ↗
33. A real-time QRS detection algorithm10.1109/TBME.1985.325532 ↗
34. Measuring agreement in method comparison studies10.1177/096228029900800204 ↗
35. Pearson’s correlation coefficient
36. BioPac, “Software,” 2020. [Online]. Available: https://www.biopac.com/product-category/research/software/.