Hemodynamic Response Detection Using Integrated EEG-fNIRS-VPA for BCI
Source abstract
Abstract
For BCI systems, it is important to have an accurate and less complex architecture to control a device with enhanced accuracy. In this paper, a novel methodology for more accurate detection of the hemodynamic response has been developed using a multimodal brain-computer interface (BCI). An integrated classifier has been developed for achieving better classification accuracy using two modalities. An integrated EEG-fNIRS-based vector-phase analysis (VPA) has been conducted. An open-source dataset collected at the Technische Universität Berlin, including simultaneous electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) signals of 26 healthy participants during n-back tests, has been used for this research. Instrumental and physiological noise removal has been done using preprocessing techniques followed by individually detecting activity in both modalities. With resting state threshold circle, VPA has been used to detect a hemodynamic response in fNIRS signals, whereas phase plots for EEG signals have been constructed using Hilbert Transform to detect the activity in each trial. Multiple threshold circles are drawn in the vector plane, where each circle is drawn after task completion in each trial of EEG signal. Finally, both processes are integrated into one vector-phase plot to get combined detection of hemodynamic response for activity. Results of this study illustrate that the combined EEG-fNIRS VPA yields considerably higher average classification accuracy, that is 91.35%, as compared to other classifiers such as support vector machine (SVM), convolutional neural networks (CNN), deep neural networks (DNN) and VPA (with dual-threshold circles) with classification accuracies 82%, 89%, 87% and 86% respectively. Outcomes of this research demonstrate that improved classification performance can be feasibly achieved using multimodal VPA for EEG-fNIRS hybrid data.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: EEG and Brain-Computer Interfaces · ECG Monitoring and Analysis · Functional Brain Connectivity Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (50)
Show source-provided references
1. Deep recurrent-convolutional neural network for classification of simultaneous EEG-fNIRS signals10.1049/iet-spr.2019.0297 ↗
2. Processing movement related cortical potentials in EEG signals for identification of slow and fast movements
3. Toward a hybrid passive BCI for the modulation of sustained attention using EEG and fNIRS10.3389/fnhum.2019.00393 ↗
4. Brain computer interfaces, a review10.3390/s120201211 ↗
5. Multimodal fNIRS-EEG classification using deep learning algorithms for brain-computer interfaces purposes
6. Hybrid brain-computer interface techniques for improved classification accuracy and increased number of commands: A review10.3389/fnbot.2017.00035 ↗
7. fNIRS-based brain-computer interfaces: A review
8. A computationally efficient method for hybrid EEG-fNIRS BCI based on the Pearson correlation10.1155/2020/1838140 ↗
9. BCI demographics: How many (and what kinds of) people can use an SSVEP BCI?10.1109/TNSRE.2009.2039495 ↗
10. Toward a compact hybrid brain-computer interface (BCI): Performance evaluation of multi-class hybrid EEG-fNIRS BCIs with limited number of channels10.1371/journal.pone.0230491 ↗
11. Performance investigation of brain-computer interfaces that combine EEG and fNIRS for motor imagery tasks
12. EEG-based control for upper and lower limb exoskeletons and prostheses: A systematic review10.3390/s18103342 ↗
13. EEG mind controlled smart prosthetic arm—A comprehensive study
14. FNIRS-based neurorobotic interface for gait rehabilitation
15. Classification of functional near-infrared spectroscopy signals corresponding to the right- and left-wrist motor imagery for development of a brain-computer10.1016/j.neulet.2013.08.021 ↗
16. A hybrid EEG-fNIRS BCI: Motor imagery for EEG and mental arithmetic for FNIRS
17. EMD-based temporal and spectral features for the classification of EEG signals using supervised learning10.1109/TNSRE.2015.2441835 ↗
18. Deep learning for hybrid EEG-fNIRS brain-computer interface: Application to motor imagery classification related content10.1088/1741-2552/aaaf82 ↗
19. Hybrid EEG-FNIRS asynchronous brain-computer interface for multiple motor tasks10.1371/journal.pone.0146610 ↗
20. Decoding of four movement directions using hybrid NIRS-EEG brain-computer interface
21. Evaluation of a compact hybrid brain-computer interface system
22. Motion artifact removal for functional near infrared spectroscopy: A comparison of methods10.1109/TBME.2009.2038667 ↗
23. Statistical analysis of fNIRS data: A comprehensive review10.1016/j.neuroimage.2013.06.016 ↗
24. Improvement of information transfer rates using a Hybrid EEG-NIRS brain-computer interface with a short trial length: Offline and pseudo-online analyses10.3390/s18061827 ↗
25. Dry electrode-based fully isolated EEG/FNIRS hybrid brain-monitoring system10.1109/TBME.2018.2866550 ↗
26. The hybrid BCI
27. Multimodal affective state assessment using FNIRS + EEG and spontaneous facial expression10.3390/brainsci10020085 ↗
28. Multisubject ‘learning’ for mental workload classification using concurrent EEG, FNIRS, and physiological measures10.3389/fnhum.2017.00389 ↗
29. Enhancing performance of a hybrid EEG-FNIRS system using channel selection and early temporal features10.3389/fnhum.2017.00462 ↗
30. A wearable multi-channel fNIRS system for brain imaging in freely moving subjects10.1016/j.neuroimage.2013.06.062 ↗
31. Simultaneous acquisition of EEG and NIRS during cognitive tasks for an open access dataset10.1038/sdata.2018.3 ↗
32. Neuronal activation detection using vector phase analysis with dual threshold circles: A functional near-infrared spectroscopy study10.1142/S0129065718500314 ↗
33. Enhancing classification accuracy of FNIRS-BCI using features acquired from vector-based phase analysis10.1088/1741-2552/abb417 ↗
34. Kato · Neuroimaging-Structure, Function and Mind · 2019
35. Reduction of delay in detecting initial dips from functional near-infrared spectroscopy signals using vector-based phase analysis10.1142/S012906571650012X ↗
36. Detection and classification of three-class initial dips from prefrontal cortex10.1364/BOE.8.000367 ↗
37. Vector-based phase classification of initial dips during word listening using near-infrared spectroscopy10.1097/WNR.0b013e328359833b ↗
38. Existence of initial dip for BCI: An illusion or reality10.3389/fnbot.2018.00069 ↗
39. Increased oxygen load in the prefrontal cortex from mouth breathing: A vector-based near-infrared spectroscopy study10.1097/WNR.0000000000000008 ↗
40. Feature extraction and classification methods for hybrid fNIRS-EEG brain-computer interfaces10.3389/fnhum.2018.00246 ↗
41. Early detection of hemodynamic responses using EEG: A hybrid EEG-FNIRS study10.3389/fnhum.2018.00479 ↗
42. Classification of mental workload (MWL) using support vector machines (SVM) and convolutional neural networks (CNN)
43. Saadati · Advances in Intelligent Systems and Computing · 2020 · 953 · 22110.1007/978-3-030-20473-0_22 ↗
44. Characterization of interictal and ictal scalp EEG signals with the Hilbert transform
45. Correlation of prefrontal cortical activation with changing vehicle speeds in actual driving: A vector-based functional near-infrared spectroscopy study10.3389/fnhum.2013.00895 ↗
46. Greater activity in the frontal cortex on left curves: A vector-based fNIRS study of left and right curve driving10.1371/journal.pone.0127594 ↗
47. Enhancing classification accuracy of FNIRS-BCI using features acquired from vector-based phase analysis10.1088/1741-2552/abb417 ↗
48. Enhanced performance by a hybrid NIRS-EEG brain computer interface10.1016/j.neuroimage.2011.07.084 ↗
49. A hybrid NIRS-EEG system for self-paced brain computer interface with online motor imagery10.1016/j.jneumeth.2014.04.016 ↗
50. An easy Z-score imaging system for discrimination between very early Alzheimer’s disease and controls using brain perfusion SPECT in a multicentre study10.1097/MNM.0b013e328013eb8b ↗