Prediction Flashover Voltage on Polluted Porcelain Insulator Using ANN
Source abstract
Abstract
This paper aims to assess the effect of dry band location of contaminated porcelain insulators under various flashover voltages due to humidity. Four locations of dry bands are proposed to be tested under different severity of contamination artificially produce using salt deposit density (SDD) sprayed on an insulator. Laboratory tests of polluted insulators under proposed scenarios have been conducted. The flashover voltage of clean insulators has been identified as a reference value to analyze the effect of contamination distribution and its severity. The dry band dimension has been taken into consideration in experimental tests. The flashover voltage has been predicted using an artificial neural network (ANN) technique based on the laboratory test data. The ANN approach is constructed with five input data (geometry the insulator and parameters of contamination) and flashover voltage as the output of the model. Results indicated that the pollution distribution based on the proposed scenario has a significant influence on the flashover voltage performances. Validation of the ANN model reveals that the relative error values between the experimental results and the prediction appeared to be within 5%. This indicates the significant efficiency of the ANN technique in predicting the flashover voltage insulator under test.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: High voltage insulation and dielectric phenomena · Image Enhancement Techniques · Power Transformer Diagnostics and Insulation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Effects of artificial tropical climate aging on insulation performance of silicone rubber polymeric insulators
2. Development of a pollution flashover model for 11 kV porcelain and silicon rubber insulator by using COMSOL multiphysics10.1007/s00202-017-0520-8 ↗
3. Effect of non-uniform pollution on the withstand characteristics of extra high voltage (EHV) suspension ceramic insulator string10.1049/iet-gtd.2009.0387 ↗
4. Contamination characteristics of typical transmission line insulators by wind tunnel simulation10.1016/j.epsr.2020.106288 ↗
5. The leakage current components as a diagnostic tool to estimate contamination level on high voltage insulators
6. DC flashover performance of insulator string with fan-shaped non-uniform pollution10.1109/TDEI.2014.004776 ↗
7. Study on AC flashover performance for different types of porcelain and glass insulators with non-uniform pollution10.1109/TPWRD.2013.2245153 ↗
8. Salem · Advances in Intelligent Systems and Computing · 2019 · 362
9. Factors and models of pollution flashover on high voltage outdoor insulators: Review
10. Investigation and analysis of ac flashover voltage of sir insulators under longitudinal and fan-shaped non-uniform pollutions10.1016/j.ijepes.2019.01.028 ↗
11. Experimental investigation on composite insulators ac flashover performance with fan-shaped non-uniform pollution under electro-thermal stress10.1016/j.ijepes.2020.106142 ↗
12. Numerical computation of electric field and potential along silicone rubber insulators under contaminated and dry band conditions10.1007/s13319-016-0101-z ↗
13. Dynamic modelling of polluted outdoor insulator under wet weather conditions
14. Improvement of electric field distribution by integrating composite insulators in a 400 kV AC double circuit line in algeria10.1109/TDEI.2017.006011 ↗
15. DC flashover dynamic model of post insulator under non-uniform pollution between windward and leeward sides10.3390/en12122345 ↗
16. A fuzzy logic optimization methodology for the estimation of the critical flashover voltage on insulators10.1016/j.epsr.2010.10.024 ↗
17. Prediction of flashover voltage of insulators using least squares support vector machine with particle swarm optimization10.1016/j.epsr.2013.06.013 ↗
18. Proposal of a dynamic numerical approach in predicting flashover critical voltage
19. Detection of polluted insulators using the information fusion of multispectral images10.1109/TDEI.2017.006516 ↗
20. A review of the dynamic modelling of pollution flashover on high voltage outdoor insulators
21. A new flashover prediction on outdoor polluted insulator using leakage current harmonic components
22. Artificial neural networks for prediction of covid-19 in Saudi Arabia10.32604/cmc.2021.013228 ↗
23. River water quality modelling using artificial neural network technique10.1016/j.aqpro.2015.02.135 ↗
24. A hybrid neural networks-fuzzy logic-genetic algorithm for grade estimation10.1016/j.cageo.2012.02.004 ↗
25. Contribution of design parameters of sir insulators to their DC pollution flashover performance10.1109/TPWRD.2013.2285223 ↗
26. Inspection in overhead insulators through the analysis of the irradiated RF spectrum10.1016/j.ijepes.2019.05.060 ↗
27. Online monitoring of medium voltage overhead distribution lines polluted insulators severity10.1049/oap-cired.2017.0056 ↗
28. Prediction of dissolved oxygen in Surma River by biochemical oxygen demand and chemical oxygen demand using the artificial neural networks (ANNs)10.1016/j.jksues.2014.05.001 ↗