Dry Fiber-Based Electrodes for Electrophysiology Applications
Source abstract
Abstract
Long-term continuous health care monitoring, using wearable technologies has received considerable interest due to the significant contribution of wearables to the diagnosis of diseases and identification of health conditions. Fibers have been widely applied in human societies due to their unique advantages, including stretchability, small diameters, high dynamic bending elasticity, high length-to-width ratios, and mechanical strength. A new generation of fiber-based electrodes is being integrated into smart textiles and wearables for continuous long-term biosignal monitoring. Dry fiber-based electrodes are breathable, flexible, and durable, unlike conventional disposable gel electrodes, which are difficult to employ for long-term applications because of skin irritation and allergic responses caused by their moist and adhesive interface with the skin. In this review, we provide a concise summary of recent breakthroughs in the design, and manufacturing of dry fiber-based electrodes for electrophysiology applications, with a particular emphasis on applications in electrocardiography, electromyography, and electroencephalography. Focusing on numerous features of electroactive fiber materials, fiber processing, electrode fabrication, scaled-up manufacturing, standardization of testing and performance criteria, we discuss current limitations and provide an outlook for the future development of this field.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Conducting polymers and applications · Muscle activation and electromyography studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Seyedin S, Carey T, Arbab A, Eskandarian L, Bohm S, Kim JM, Torrisi F. Fibre electronics: towards scaled-up manufacturing of integrated e-textile systems. Nanoscale. 2021;13:12818–47.10.1039/D1NR02061G ↗
2. Webster J, Nimunkar A. Medical instrumentation: application and design. 5th ed. New York: Wiley; 2020.
3. Serhani MA, El Kassabi HT, Ismail H, Navaz AN. ECG monitoring systems: review, architecture, processes, and key challenges. Sensors. 2020;20:1796.10.3390/s20061796 ↗
4. Garvey JL. ECG techniques and technologies. Emerg Med Clin N Am. 2006;24:209–25 (viii).10.1016/j.emc.2005.08.013 ↗
5. Campanini I, Disselhorst-Klug C, Rymer WZ, Merletti R. Surface EMG in clinical assessment and neurorehabilitation: barriers limiting its use. Front Neurol. 2020;11:934.10.3389/fneur.2020.00934 ↗
6. Mills KR. The basics of electromyography. J Neurol Neurosurg Psychiatry. 2005;76(Suppl 2):ii32–5.
7. Roche AD, Rehbaum H, Farina D, Aszmann OC. Prosthetic myoelectric control strategies: a clinical perspective. Curr Surg Rep. 2014;2:44.10.1007/s40137-013-0044-8 ↗
8. Rodríguez-Tapia B, Soto I, Martínez D, Arballo N. Myoelectric interfaces and related applications: current state of EMG signal processing—a systematic review. IEEE Access. 2020;8:7792–805.10.1109/ACCESS.2019.2963881 ↗
9. Fountain NB, Freeman JM. EEG is an essential clinical tool: pro and con. Epilepsia. 2006;47(Suppl 1):23–5.10.1111/j.1528-1167.2006.00655.x ↗
10. Rundo JV, Downey R. Polysomnography. In: Levin KH, Chauvel P, editors. Handbook of clinical neurology. Cleveland: Elsevier; 2019. p. 381–92.
11. Pani D, Achilli A, Bonfiglio A. Survey on textile electrode technologies for electrocardiographic (ECG) monitoring, from metal wires to polymers. Adv Mater Technol. 2018;3:1800008.10.1002/admt.201800008 ↗
12. Pani D, Dessi A, Saenz-Cogollo JF, Barabino G, Fraboni B, Bonfiglio A. Fully textile, PEDOT:PSS based electrodes for wearable ECG monitoring systems. IEEE Trans Biomed Eng. 2016;63:540–9.10.1109/TBME.2015.2465936 ↗
13. Johns Hopkins Medicine. Holter monitor. 2022. https://www.hopkinsmedicine.org/health/treatment-tests-and-therapies/holter-monitor. Accessed 29 Jun 2022.
14. Yao S, Zhu Y. Nanomaterial-enabled dry electrodes for electrophysiological sensing: a review. JOM. 2016;68:1145–55.10.1007/s11837-016-1818-0 ↗
15. Searle A, Kirkup L. A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiol Meas. 2000;21:271–83.10.1088/0967-3334/21/2/307 ↗
16. Xu PJ, Zhang H, Tao XM. Textile-structured electrodes for electrocardiogram. Text Prog. 2008;40:183–213.10.1080/00405160802597479 ↗
17. Huang CY, Chiu CW. Facile fabrication of a stretchable and flexible nanofiber carbon film-sensing electrode by electrospinning and its application in smart clothing for ECG and EMG monitoring. ACS Appl Electron Mater. 2021;3:676–86.10.1021/acsaelm.0c00841 ↗
18. Fu Y, Zhao J, Dong Y, Wang X. Dry electrodes for human bioelectrical signal monitoring. Sensors (Basel). 2020;20:3651.10.3390/s20133651 ↗
19. Liu L, Xu W, Ding Y, Agarwal S, Greiner A, Duan G. A review of smart electrospun fibers toward textiles. Compos Commun. 2020;22: 100506.10.1016/j.coco.2020.100506 ↗
20. Li Q, Ding C, Yuan W, Xie R, Zhou X, Zhao Y, Yu M, Yang Z, Sun J, Tian Q, Han F, Li H, Deng X, Li G, Liu Z. Highly stretchable and permeable conductors based on shrinkable electrospun fiber mats. Adv Fiber Mater. 2021;3:302–11.10.1007/s42765-021-00079-7 ↗
21. Ryan JD, Mengistie DA, Gabrielsson R, Lund A, Müller C. Machine-washable PEDOT:PSS dyed silk yarns for electronic textiles. ACS Appl Mater Interfaces. 2017;9:9045–50.10.1021/acsami.7b00530 ↗
22. Taylor LW, Williams SM, Yan JS, Dewey OS, Vitale F, Pasquali M. Washable, sewable, all-carbon electrodes and signal wires for electronic clothing. Nano Lett. 2021;21:7093–9.10.1021/acs.nanolett.1c01039 ↗
23. Lekawa-Raus A, Patmore J, Kurzepa L, Bulmer J, Koziol K. Electrical properties of carbon nanotube based fibers and their future use in electrical wiring. Adv Funct Mater. 2014;24:3661–82.10.1002/adfm.201303716 ↗
24. Weder M, Hegemann D, Amberg M, Hess M, Boesel LF, Abächerli R, Meyer VR, Rossi RM. Embroidered electrode with silver/titanium coating for long-term ECG monitoring. Sensors (Basel). 2015;15:1750–9.10.3390/s150101750 ↗
25. Eskandarian L, Toossi A, Nassif F, Rostami SG, Ni S, Mahnam A, Meghrazi MA, Takarada W, Kikutani T, Naguib HE. 3D-knit dry electrodes using conductive elastomeric fibers for long-term continuous electrophysiological monitoring. Adv Mater Technol. 2022;7:2101572.10.1002/admt.202101572 ↗
26. Alizadeh-Meghrazi M, Sidhu G, Jain S, Stone M, Eskandarian L, Toossi A, Popovic MR. A mass-producible washable smart garment with embedded textile EMG electrodes for control of myoelectric prostheses: a pilot study. Sensors (Basel). 2022;22:666.10.3390/s22020666 ↗
27. Arquilla K, Devendorf L, Webb AK, Anderson AP. Detection of the complete ECG waveform with woven textile electrodes. Biosensors (Basel). 2021;11:331.10.3390/bios11090331 ↗
28. Arquilla K, Webb A, Anderson A. Woven electrocardiogram (ECG) electrodes for health monitoring in operational environments. In: 42nd Annual International Conference of the IEEE engineering in medicine & biology society (EMBC). Montreal, QC: IEEE; 2020, pp. 4498–4501.10.1109/EMBC44109.2020.9176478 ↗
29. Arquilla K, Webb AK, Anderson AP. Textile electrocardiogram (ECG) electrodes for wearable health monitoring. Sensors (Basel). 2020;20:1013.10.3390/s20041013 ↗
30. Mestrovic M, Helmer R, Kyratzis L, Kumar D. Preliminary study of dry knitted fabric electrodes for physiological monitoring. In: 3rd International Conference on intelligent sensors, sensor networks and information. Melbourne, Australia: IEEE; 2007, pp. 601–606.10.1109/ISSNIP.2007.4496911 ↗
31. Xiao X, Dong K, Li C, Wu G, Zhou H, Gu Y. A comfortability and signal quality study of conductive weave electrodes in long-term collection of human electrocardiographs. Text Res J. 2019;89:2098–112.10.1177/0040517518786275 ↗
32. Lee JW, Yun KS. ECG monitoring garment using conductive carbon paste for reduced motion artifacts. Polymers (Basel). 2017;9:439.10.3390/polym9090439 ↗
33. Eskandarian L, Lam E, Rupnow C, Meghrazi MA, Naguib HE. Robust and multifunctional conductive yarns for biomedical textile computing. ACS Appl Electron Mater. 2020;2:1554–66.10.1021/acsaelm.0c00171 ↗
34. Logothetis I, Bayramol DV, Gil I, Dabnichki P, Pirogova E. Evaluating silver-plated nylon (Ag/PA66) e-textiles for bioelectrical impedance analysis (BIA) application. Meas Sci Technol. 2020;31: 075101.10.1088/1361-6501/ab78c3 ↗
35. Coyle S, Lau K, Moyna N, O’Gorman D, Diamond D, Di Francesco F, Costanzo D, Salvo P, Trivella M, De Rossi D, Taccini N, Paradiso R, Porchet J, Ridolfi A, Luprano J, Chuzel C, Lanier T, Revol-Cavalier F, Schoumacker S, Mourier V, Chartier I, Convert R, De-Moncuit H, Bini C. BIOTEX—biosensing textiles for personalised healthcare management. IEEE Trans Inf Technol Biomed. 2010;14:364–70.10.1109/TITB.2009.2038484 ↗
36. Paradiso R, Loriga G, Taccini N. A wearable health care system based on knitted integrated sensors. IEEE Trans Inf Technol Biomed. 2005;9:337–44.10.1109/TITB.2005.854512 ↗
37. Kim H, Kim E, Choi C, Yeo WH. Advances in soft and dry electrodes for wearable health monitoring devices. Micromachines (Basel). 2022;13:629.10.3390/mi13040629 ↗
38. Rattfält L, Lindén M, Hult P, Berglin L, Ask P. Electrical characteristics of conductive yarns and textile electrodes for medical applications. Med Biol Eng Comput. 2007;45:1251–7.10.1007/s11517-007-0266-y ↗
39. Taji B, Shirmohammadi S, Groza V, Batkin I. Impact of skin–electrode interface on electrocardiogram measurements using conductive textile electrodes. IEEE Trans Instrum Meas. 2014;63:1412–22.10.1109/TIM.2013.2289072 ↗
40. Cömert A, Hyttinen J. Impedance spectroscopy of changes in skin-electrode impedance induced by motion. Biomed Eng Online. 2014;13:149.10.1186/1475-925X-13-149 ↗
41. Lee S, Kim M, Kang T, Park J, Choi Y. Knit band sensor for myoelectric control of surface EMG-based prosthetic hand. IEEE Sens J. 2018;18:8578–86.10.1109/JSEN.2018.2865623 ↗
42. An X, Tangsirinaruenart O, Stylios GK. Investigating the performance of dry textile electrodes for wearable end-uses. J Text Inst. 2019;110:151–8.10.1080/00405000.2018.1508799 ↗
43. Logothetis I, Fernandez-Garcia R, Troynikov O, Dabnichki P, Pirogova E, Gil I. Embroidered electrodes for bioelectrical impedance analysis: impact of surface area and stitch parameters. Meas Sci Technol. 2019;30: 115103.10.1088/1361-6501/ab3201 ↗
44. Soroudi A, Hernández N, Wipenmyr J, Nierstrasz V. Surface modification of textile electrodes to improve electrocardiography signals in wearable smart garment. J Mater Sci Mater Electron. 2019;30:16666–75.10.1007/s10854-019-02047-9 ↗
45. Cobarrubias E. Design and test strategies for biopotential sensors in smart garments. Master thesis. Raleigh, NC: North Carolina State University; 2020.
46. Goyal K, Borkholder DA, Day SW. A biomimetic skin phantom for characterizing wearable electrodes in the low-frequency regime. Sens Actuators A Phys. 2022;340: 113513.10.1016/j.sna.2022.113513 ↗
47. Alizadeh-Meghrazi M, Ying B, Schlums A, Lam E, Eskandarian L, Abbas F, Sidhu G, Mahnam A, Moineau B, Popovic MR. Evaluation of dry textile electrodes for long-term electrocardiographic monitoring. Biomed Eng Online. 2021;20:68.10.1186/s12938-021-00905-4 ↗
48. Beckmann L, Neuhaus C, Medrano G, Jungbecker N, Walter M, Gries T, Leonhardt S. Characterization of textile electrodes and conductors using standardized measurement setups. Physiol Meas. 2010;31:233–47.10.1088/0967-3334/31/2/009 ↗
49. Lam E, Alizadeh-Meghrazi M, Schlums A, Eskandarian L, Mahnam A, Moineau B, Popovic MR. Exploring textile-based electrode materials for electromyography smart garments. J Rehabil Assist Technol Eng. 2022. https://doi.org/10.1177/20556683211061995.10.1177/20556683211061995 ↗
50. Woelfling B, Classen E, Klepser A, Gerhardts A. Comfort rating for upholstery systems. In: 2nd International Comfort Congress. Delft, Netherlands; 2019, pp. 1–7.
51. Casson AJ. Wearable EEG and beyond. Biomed Eng Lett. 2019;9:53–71.10.1007/s13534-018-00093-6 ↗
52. Priniotakis G, Westbroek P, Van Langenhove L, Hertleer C. Electrochemical impedance spectroscopy as an objective method for characterization of textile electrodes. Trans Inst Meas Control. 2007;29:271–81.10.1177/0142331207081605 ↗
53. An X, Stylios GK. A hybrid textile electrode for electrocardiogram (ECG) measurement and motion tracking. Materials (Basel). 2018;11:1887.10.3390/ma11101887 ↗
54. Neto JP, Baião P, Lopes G, Frazão J, Nogueira J, Fortunato E, Barquinha P, Kampff AR. Does impedance matter when recording spikes with polytrodes? Front Neurosci. 2018;12:715.10.3389/fnins.2018.00715 ↗
55. Tseghai G, Malengier B, Fante K, Van Langenhove L. Dry electroencephalography textrode for brain activity monitoring. IEEE Sens J. 2021;21:22077–85.10.1109/JSEN.2021.3103411 ↗
56. Meziane N, Webster JG, Attari M, Nimunkar AJ. Dry electrodes for electrocardiography. Physiol Meas. 2013;34:R47–69.10.1088/0967-3334/34/9/R47 ↗
57. Tseghai GB, Malengier B, Fante KA, Van Langenhove L. The status of textile-based dry EEG electrodes. Autex Res J. 2021;21:63–70.10.2478/aut-2019-0071 ↗
58. Marozas V, Petrenas A, Daukantas S, Lukosevicius A. A comparison of conductive textile-based and silver/silver chloride gel electrodes in exercise electrocardiogram recordings. J Electrocardiol. 2011;44:189–94.10.1016/j.jelectrocard.2010.12.004 ↗
59. Song HY, Lee JH, Kang D, Cho H, Cho HS, Lee JW, Lee YJ. Textile electrodes of jacquard woven fabrics for biosignal measurement. J Text Inst. 2010;101:758–70.10.1080/00405000903442086 ↗
60. Cho HS, Koo SM, Lee J, Cho H, Kang DH, Song HY, Lee JW, Lee KH, Lee YJ. Heart monitoring garments using textile electrodes for healthcare applications. J Med Syst. 2011;35:189–201.10.1007/s10916-009-9356-8 ↗
61. Nigusse A, Malengier B, Mengistie D, Van Langenhove L. Evaluation of silver-coated textile electrodes for ECG recording. In: IEEE International Conference on flexible and printable sensors and systems (FLEPS). Manchester, UK: IEEE; 2021, pp. 1–4.10.1109/FLEPS51544.2021.9469834 ↗
62. Meghrazi MA, Tian Y, Mahnam A, Bhattachan P, Eskandarian L, Kakhki ST, Popovic MR, Lankarany M. Multichannel ECG recording from waist using textile sensors. Biomed Eng Online. 2020;19:48.10.1186/s12938-020-00788-x ↗
63. Yan JS, Orecchioni M, Vitale F, Coco JA, Duret G, Antonucci S, Pamulapati SS, Taylor LW, Dewey OS, Di Sante M, Segura AM, Gurcan C, Di Lisa F, Yilmazer A, McCauley MD, Robinson JT, Razavi M, Ley K, Delogu LG, Pasquali M. Biocompatibility studies of macroscopic fibers made from carbon nanotubes: implications for carbon nanotube macrostructures in biomedical applications. Carbon. 2021;173:462–76.10.1016/j.carbon.2020.10.077 ↗
64. Zhang X, Zhong Y. Development of woven textile electrodes with enhanced moisture-wicking properties. J Text Inst. 2021;112:983–95.10.1080/00405000.2020.1794665 ↗
65. Li M, Xiong W, Li Y. Wearable measurement of ECG signals based on smart clothing. Int J Telemed Appl. 2020;2020:6329360.
66. Lee S, Sung M, Choi Y. Wearable fabric sensor for controlling myoelectric hand prosthesis via classification of foot postures. Smart Mater Struct. 2020;29: 035004.10.1088/1361-665X/ab6690 ↗
67. Zaman SU, Tao X, Cochrane C, Koncar V. Understanding the washing damage to textile ECG dry skin electrodes, embroidered and fabric-based; set up of equivalent laboratory tests. Sensors (Basel). 2020;20:1272.10.3390/s20051272 ↗
68. Gaubert V, Gidik H, Bodart N, Koncar V. Quantification of the silver content of a silver-plated nylon electrode according to the nature of the laundering detergent. IOP Conf Ser Mater Sci Eng. 2020;827: 012033.10.1088/1757-899X/827/1/012033 ↗
69. Fouassier D, Roy X, Blanchard A, Hulot JS. Assessment of signal quality measured with a smart 12-lead ECG acquisition T-shirt. Ann Noninvasive Electrocardiol. 2020;25: e12682.10.1111/anec.12682 ↗
70. Tsukada YT, Tokita M, Murata H, Hirasawa Y, Yodogawa K, Iwasaki YK, Asai K, Shimizu W, Kasai N, Nakashima H, Tsukada S. Validation of wearable textile electrodes for ECG monitoring. Heart Vessels. 2019;34:1203–11.10.1007/s00380-019-01347-8 ↗
71. Isezaki T, Kadone H, Niijima A, Aoki R, Watanabe T, Kimura T, Suzuki K. Sock-type wearable sensor for estimating lower leg muscle activity using distal EMG signals. Sensors (Basel). 2019;19:1954.10.3390/s19081954 ↗
72. Ankhili A, Zaman S, Tao X, Cochrane C, Koncar V, Coulon D. How to connect conductive flexible textile tracks to skin electrocardiography electrodes and protect them against washing. IEEE Sens J. 2019;19:11995–2002.10.1109/JSEN.2019.2938333 ↗
73. Xiao X, Pirbhulal S, Dong K, Wu W, Mei X. Performance evaluation of plain weave and honeycomb weave electrodes for human ECG monitoring. J Sens. 2017;2017:7539840.10.1155/2017/7539840 ↗
74. Tsukada S, Nakashima H, Torimitsu K. Conductive polymer combined silk fiber bundle for bioelectrical signal recording. PLoS ONE. 2012;7: e33689.10.1371/journal.pone.0033689 ↗
75. Lorussi F, Carbonaro N, De Rossi D, Paradiso R, Veltink P, Tognetti A. Wearable textile platform for assessing stroke patient treatment in daily life conditions. Front Bioeng Biotechnol. 2016;4:28.10.3389/fbioe.2016.00028 ↗
76. Brown S, Ortiz-Catalan M, Petersson J, Rödby K, Seoane F. Intarsia-sensorized band and textrodes for real-time myoelectric pattern recognition. In: 38th Annual International Conference of the IEEE engineering in medicine and biology society (EMBC). Orlando, FL: IEEE; 2016, pp. 6074–6077.10.1109/EMBC.2016.7592114 ↗
77. Amberg M, Rupper P, Storchenegger R, Weder M, Hegemann D. Controlling the release from silver electrodes by titanium adlayers for health monitoring. Nanomedicine. 2015;11:845–53.10.1016/j.nano.2014.12.017 ↗
78. Kannaian T, Neelaveni R, Thilagavathi G. Design and development of embroidered textile electrodes for continuous measurement of electrocardiogram signals. J Ind Text. 2013;42:303–18.10.1177/1528083712438069 ↗
79. Cho G, Jeong K, Paik M, Kwun Y, Sung M. Performance evaluation of textile-based electrodes and motion sensors for smart clothing. IEEE Sens J. 2011;11:3183–93.10.1109/JSEN.2011.2167508 ↗
80. Jourand P, De Clercq H, Puers R. Robust monitoring of vital signs integrated in textile. Sens Actuators A Phys. 2010;161:288–96.10.1016/j.sna.2010.05.002 ↗
81. Jourand P, De Clercq H, Corthout R, Puers R. Textile integrated breathing and ECG monitoring system. Proc Chem. 2009;1:722–5.10.1016/j.proche.2009.07.180 ↗
82. Bouwstra S, Chen W, Feijs L, Oetomo S. Smart jacket design for neonatal monitoring with wearable sensors. In: Sixth International Workshop on wearable and implantable body sensor networks. Berkeley, CA: IEEE; 2009, pp. 162–167.10.1109/BSN.2009.40 ↗
83. Zheng JW, Zhang ZB, Wu TH, Zhang Y. A wearable mobihealth care system supporting real-time diagnosis and alarm. Med Biol Eng Comput. 2007;45:877–85.10.1007/s11517-007-0221-y ↗
84. Shen C, Kao T, Huang C, Lee J. Wearable band using a fabric-based sensor for exercise ECG monitoring. In: 10th IEEE International Symposium on wearable computers. Montreux, Switzerland: IEEE; 2006, pp. 143–144.10.1109/ISWC.2006.286367 ↗
85. Lobodzinski SM, Laks MM. Biopotential fiber sensor. J Electrocardiol. 2006;39:S41–6.10.1016/j.jelectrocard.2006.05.016 ↗
86. Scilingo EP, Gemignani A, Paradiso R, Taccini N, Ghelarducci B, De Rossi D. Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables. IEEE Trans Inf Technol Biomed. 2005;9:345–52.10.1109/TITB.2005.854506 ↗
87. Pacelli M, Loriga G, Taccini N, Paradiso R. Sensing fabrics for monitoring physiological and biomechanical variables: e-textile solutions. In: 3rd IEEE/EMBS International Summer School on medical devices and biosensors. Cambridge, MA: IEEE; 2006, pp. 1–4.10.1109/ISSMDBS.2006.360082 ↗
88. Catrysse M, Puers R, Hertleer C, Van Langenhove L, Van Egmond H, Matthys D. Towards the integration of textile sensors in a wireless monitoring suit. Sens Actuators A Phys. 2004;114:302–11.10.1016/j.sna.2003.10.071 ↗
89. Fleury A, Alizadeh M, Stefan G, Chau T. Toward fabric-based EEG access technologies: seamless knit electrodes for a portable brain-computer interface. In: IEEE life sciences conference (LSC). Sydney, Australia: IEEE; 2017, pp. 35–38.10.1109/LSC.2017.8268137 ↗
90. Pitou S, Wu F, Shafti A, Michael B, Stopforth R, Howard M. Embroidered electrodes for control of affordable myoelectric prostheses. In: IEEE International Conference on robotics and automation (ICRA). Brisbane, Australia: IEEE; 2018, pp. 1812–1817.10.1109/ICRA.2018.8461066 ↗
91. Löfhede J, Seoane F, Thordstein M. Soft textile electrodes for EEG monitoring. In: Proceedings of the 10th IEEE International Conference on information technology and applications in biomedicine. Corfu, Greece: IEEE; 2010, pp. 1–4.10.1109/ITAB.2010.5687755 ↗
92. Silva M, Catarino A, Carvalho H, Rocha A, Monteiro J, Montagna G. Study of vital sign monitoring with textile sensors in swimming pool environment. In: 35th annual Conference of IEEE industrial electronics. Porto, Portugal: IEEE; 2009, pp. 4426–4431.10.1109/IECON.2009.5414898 ↗
93. Goverdovsky V, Looney D, Kidmose P, Mandic D. In-ear EEG from viscoelastic generic earpieces: robust and unobtrusive 24/7 monitoring. IEEE Sens J. 2016;16:271–7.10.1109/JSEN.2015.2471183 ↗
94. Finni T, Hu M, Kettunen P, Vilavuo T, Cheng S. Measurement of EMG activity with textile electrodes embedded into clothing. Physiol Meas. 2007;28:1405–19.10.1088/0967-3334/28/11/007 ↗
95. Tikkanen O, Hu M, Vilavuo T, Tolvanen P, Cheng S, Finni T. Ventilatory threshold during incremental running can be estimated using EMG shorts. Physiol Meas. 2012;33:603–14.10.1088/0967-3334/33/4/603 ↗
96. Colyer SL, McGuigan PM. Textile electrodes embedded in clothing: a practical alternative to traditional surface electromyography when assessing muscle excitation during functional movements. J Sports Sci Med. 2018;17:101–9.
97. Coosemans J, Hermans B, Puers R. Integrating wireless ECG monitoring in textiles. In: The 13th international conference on solid-state sensors, actuators and microsystems, 2005. Digest of technical papers. TRANSDUCERS '05. Seoul, South Korea: IEEE; 2005, pp. 228–232.10.1109/SENSOR.2005.1496399 ↗
98. Mattila H. Intelligent textiles and clothing. Boca Raton, FL: CRC Press; 2006.10.1533/9781845691622 ↗
99. Honarvar MG, Latifi M. Overview of wearable electronics and smart textiles. J Text Inst. 2017;108:631–52.10.1080/00405000.2016.1177870 ↗
100. Memon SF, Memon M, Bhatti S. Wearable technology for infant health monitoring: a survey. IET Circuits Devices Syst. 2020;14:115–29.10.1049/iet-cds.2018.5447 ↗