Parameters optimization design method for LLC resonant converter based on impedance model
Source abstract
Abstract
Purpose This paper aims to better design the resonant tank parameters for LLC resonant converter. And, it is found that under heavy load, the voltage gain is affected by junction capacitors of the primary side switching and the parasitic parameters of the secondary side diodes converted to the primary side, which will cause the voltage gain decreased when the switching frequency decreased. Design/methodology/approach This paper proposes an optimization parameters design method to solve this problem, which was based on impedance model considering the parasitic parameters of switching devices and diodes. Findings The effectiveness of the proposed method is verified by impedance Bode plots and experimental results. Originality/value From the perspective of impedance modeling, this paper finds the reasons for the insufficient voltage regulation capability of LLC resonant converters under heavy load and finds solutions through analysis.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced DC-DC Converters · Multilevel Inverters and Converters · Induction Heating and Inverter Technology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References